Cheng-Kuang Huang

Cheng-Kuang Huang

Auto-generated profile, based on publicly available information

Cheng-Kuang Huang

Mechanobiology Institute, National University of Singapore

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2011 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
CHCheng-Kuang Huang
Cheng-Kuang Huang
YOYongxi Ou
Yongxi Ou
YBYaqing Bie
Yaqing Bie
QZQing Zhao
Qing Zhao
DYDapeng Yu
Dapeng Yu
Well-aligned graphene field emission arrays were fabricated on copper foils via simple photolithography and wet etching techniques. The method offered high-ordered micro sized graphene pattern in the array elements. Field emission measurement revealed a turn-on field of 7.2 V/μm at 100 nA/cm2 and a good emission current stability. Exposed graphene edges were produced on each array element edge and found to be the significant contributors to the emission current. Owing to the obvious advantages of low cost and easy for scale-up production, this method demonstrates the feasibility of utilizing such graphene field emission array configurations in display applications.

1 May 2010 in Biomaterials
Verified
Journal Article
Closed access
CCCheng-Lung Chen
Cheng-Lung Chen
LKLing-Ru Kuo
Ling-Ru Kuo
CCChing-Lin Chang
Ching-Lin Chang
YHYeu-Kuang Hwu
Yeu-Kuang Hwu
CHCheng-Kuang Huang
Cheng-Kuang Huang
YCYang-Yuan Chen
Yang-Yuan Chen

9 May 2011 in Chemical Communications
Verified
Journal Article
Closed access
PDF file
YCYouqiang Chen
Youqiang Chen
XZXinni Zhang
Xinni Zhang
QZQing Zhao
Qing Zhao
LHLi He
Li He
CHChengkuang Huang
Chengkuang Huang
ZXZhipeng Xie
Zhipeng Xie
We report for the first time the fabrication of p-type SiC nanowire field-effect transistors (FETs) using an individual Al-doped 3C-SiC nanowire with a single crystalline structure. The Raman spectroscopy of the as-grown p-type wire indicates that the linewidth and peak intensity of LO-phonon bands are sensitive to temperature variations.

26 February 2020 in Biofabrication
Verified
Journal Article
Open access
PDF file
CHCheng-Kuang Huang
Cheng-Kuang Huang
GPGiovanni J Paylaga
Giovanni J Paylaga
SBSasinan Bupphathong
Sasinan Bupphathong
KLKeng-Hui Lin
Keng-Hui Lin
Microwell arrays have emerged as three-dimensional substrates for cell culture due to their simplicity of fabrication and promise for high-throughput applications such as 3D cell-based assays for drug screening. To date, most microwells have had cylindrical geometries. Motivated by our previous findings that cells display 3D physiological characteristics when grown in the spherical micropores of monodisperse foam scaffolds (Lee et al 2013 Integr. Biol. 5 1447–55 and Lin et al 2011 Soft Matter 7 10010–6), here we engineered novel microwells shaped as spherical caps with obtuse polar angles, yielding narrow apertures. When used as bare substrates, these microwells were suitable for culturing cell spheroids; the narrow apertures sterically hindered unattached cultured cells from rolling out of microwells under agitation. When only the walls of the microwell were conjugated with extracellular matrix proteins, cells remained confined in the microwells. Epithelial cells proliferated and burst out of the aperture, and cell polarity was oriented based on the distribution of extracellular matrix proteins in the microwells. Surprisingly, single fibroblast cells in spherical wells of various diameters (40–100 μm) underwent cell-cycle arrest, while cells in circular cylindrical microwells continued to proliferate. Spatial confinement was not sufficient to cause cell-cycle arrest; however, confinement in a constant negative-curvature microenvironment led to cell-cycle arrest. Overall, these investigations demonstrate that this spherical microwell substrate constitutes a novel basic research tool for elucidating how cells respond to dimensionality and microenvironment with radii of curvature at the cellular length scale.

30 November 2011 in Solid State Communications
Verified
Journal Article
Closed access
QZQing Zhao
Qing Zhao
CHCheng-Kuang Huang
Cheng-Kuang Huang
RZRui Zhu
Rui Zhu
Jun XuJun Xu
Jun Xu
LCLi Chen
Li Chen
DYDapeng Yu
Dapeng Yu

6 January 2015 in Journal of The Royal Society Interface
Verified
Journal Article
Open access
PDF file
CHCheng-Kuang Huang
Cheng-Kuang Huang
ADAthene Donald
Athene Donald
Since the dawn of in vitro cell cultures, how cells interact and proliferate within a given external environment has always been an important issue in the study of cell biology. It is now well known that mammalian cells typically exhibit a three-phase sigmoid spreading on encountering a substrate. To further this understanding, we examined the influence of cell shape towards the second rapid expansion phase of spreading. Specifically, 3T3 fibroblasts were seeded onto silicon elastomer films made from polydimethylsiloxane (PDMS), and micro-contact printed with fibronectin stripes of various dimensions. PDMS is adopted in our study for its biocompatibility, its ease in producing very smooth surfaces, and in the fabrication of micro-contact printing stamps. The substrate patterns are compared with respect to their influence on cell spreading over time. Our studies reveal, during the early rapid expansion phase, 3T3 fibroblasts are found to spread radially following a law; meanwhile, they proliferated in a lengthwise fashion on the striped patterns, following a law. We account for the observed differences in kinetics through a simple geometric analysis which predicted similar trends. In particular, a t 2 law for radial spreading cells, and a t 1 law for lengthwise spreading cells.