Alex J. Lancaster

Alex J. Lancaster

Auto-generated profile, based on publicly available information

Alex J. Lancaster

Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, Ohio

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2022 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
ALAlex Lancaster
Alex Lancaster
MCMatthew Christie
Matthew Christie
BBBrenna E. Blackburn
Brenna E. Blackburn
CPChristopher E. Pelt
Christopher E. Pelt
CPChristopher L. Peters
Christopher L. Peters
LALucas A. Anderson
Lucas A. Anderson

1 June 2021 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
ALAlex J. Lancaster
Alex J. Lancaster
VCVictor R. Carlson
Victor R. Carlson
CPChristopher E. Pelt
Christopher E. Pelt
LALucas A. Anderson
Lucas A. Anderson
CPChristopher L. Peters
Christopher L. Peters
JGJeremy M. Gililland
Jeremy M. Gililland

10 August 2023 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
ALAlex J. Lancaster
Alex J. Lancaster
KSKimberly L. Stevenson
Kimberly L. Stevenson
PNPaighton H. Noel
Paighton H. Noel
OGOlivia F. Grothaus
Olivia F. Grothaus
BBBrenna E. Blackburn
Brenna E. Blackburn
JGJeremy M. Gililland
Jeremy M. Gililland

1 October 2024 in JBJS Essential Surgical Techniques
Verified
Journal Article
Closed access
NPNicolas S. Piuzzi
Nicolas S. Piuzzi
NHNickelas Huffman
Nickelas Huffman
ALAlex Lancaster
Alex Lancaster
MDMatthew E. Deren
Matthew E. Deren
Background: Unicompartmental knee arthroplasty (UKA) procedures have become much more common in the United States in recent years, with >40,000 UKAs performed annually 1 . However, it is estimated that 10% to 40% of UKAs fail and thus require conversion to total knee arthroplasty (TKA) 2–5 . In the field of total joint arthroplasty, robotic-assisted surgeries have demonstrated advantages such as better accuracy and precision of implant positioning and improved restoration of a neutral mechanical axis 6–9 . These advantages may be useful in UKA to TKA conversion surgeries, as the use of robotic assistance may result in improved bone preservation. Description: Robotic-assisted TKA is performed with the patient in the supine position, under spinal anesthesia, and with use of a tourniquet. A limited incision is made approximately 1 cm medial to a standard midline incision, through the previous UKA incision. A medial parapatellar arthrotomy and partial synovectomy are performed. Array pins are placed in a standard fashion: intra-incisional in the femoral diaphysis and extra-incisional in the distal tibial diaphysis. Femoral and tibial bone registration is performed, along with functional knee balancing to adjust implant positioning. The robotic arm-assisted system is then utilized to achieve the planned bone resections. After completing all bone cuts, trial components are inserted. Trial reduction is then performed, and knee extension, stability, and range of motion are assessed. The final implant is cemented into place. We utilize a cruciate-retaining TKA implant. No augments are required. Alternatives: An alternative treatment option is manual UKA to TKA conversion. Rationale: Robotic-assisted conversion of UKA to TKA is especially useful for patients requiring bone preservation. For example, 1 case series found that the use of robotic-assisted conversion of UKA to TKA resulted in a decreased use of augments and a smaller average polyethylene insert thickness compared with manual conversion. Furthermore, mechanical bone loss may occur secondary to implant loosening. Thus, in patients with aseptic loosening, robotic-assisted conversion of UKA to TKA may be useful 10 . Expected Outcomes: Results of robotic-assisted conversion of UKA to TKA have thus far been excellent. In a study of 4 patients undergoing robotic-assisted conversion of UKA to TKA, all patients experienced uneventful recoveries without any need for subsequent re-revision 10 . In a case report of a robotic-assisted conversion of UKA to TKA, the patient was pain-free at both 6 months and 1 year postoperatively, with a range of motion of 0° to 120° at 6 months and 0° to 130° at 1 year, and excellent component alignment on radiographs at 1 year 11 . In another case report, the patient had full range of motion and a normal, painless gait at 1 year postoperatively 12 . When comparing manual versus robotic-assisted conversion, 1 study found no difference in postoperative range of motion or complications among the 28 patients assessed 13 . Important Tips: Ensure accurate soft-tissue balancing prior to implant removal and osseous resection. Augments can easily be cut by executing the initial cut, then moving the resection depth either 5 or 10 mm deeper. The cut is then performed only in the compartment that needs an augment. Augment cutting is usually performed in a stepwise fashion to avoid excessive resection in the other compartments in order to preserve native bone. Having revision implants with increased constraint and metaphyseal fixation available is important during these cases because, as in any revision surgery, unexpected events can lead to the need for other implant choices. Acronyms and Abbreviations: UKA = unicompartmental knee arthroplasty RA = robotic-assisted TKA = total knee arthroplasty ROM = range of motion CT = computed tomography PCL = posterior cruciate ligament DVT = deep venous thrombosis VTE = venous thromboembolism

7 June 2022 in Arthroplasty Today
Verified
Journal Article
Open access
ALAlex Lancaster
Alex Lancaster
ETEmily Treu
Emily Treu
JGJeremy Gililland
Jeremy Gililland
LALucas Anderson
Lucas Anderson
As surgeons' comfort with the direct anterior approach (DAA) for total hip arthroplasty continues to increase, there is a growing interest in performing complex surgeries through this approach. Acetabular bone loss and/or pelvic discontinuity in the primary or revision setting often requires specialized implants such as a cup-cage construct. We describe our surgical technique for implanting modified cup-half cages through the DAA and show 2 case examples of how this technique was utilized in the setting of complex acetabular bone loss. In our experience, this is an effective method for complex total hip arthroplasty, with the potential added benefits of the DAA of reduced soft-tissue dissection, direct measurement of leg length, and ease of fluoroscopic navigation for implant positioning.

29 March 2024 in Arthroplasty Today
Verified
Journal Article
Open access
LRLogan Radtke
Logan Radtke
JFJeffrey J. Frandsen
Jeffrey J. Frandsen
ALAlex J. Lancaster
Alex J. Lancaster
SLShanna Loughmiller
Shanna Loughmiller
BBBrenna E. Blackburn
Brenna E. Blackburn
JGJeremy M. Gililland
Jeremy M. Gililland
Additive manufacturing has recently gained popularity and is widely adopted in the orthopaedic industry. However, there is a paucity of literature on the radiographic and clinical outcomes of these relatively novel components. The aim of this study was to assess the 2-year clinical and radiographic outcomes of a specific additive-manufactured acetabular component in primary total hip arthroplasty. We performed a retrospective review of 60 patients who underwent primary total hip arthroplasty with the use of the Stryker’s TRIDENT II acetabular component. Evaluation of radiographs was performed at 6 weeks, 1 year, and 2 years postoperatively. Radiographs were evaluated for radiolucencies in Charnley and DeLee zones, signs of biologic fixation, and acetabular inclination and anteversion measurements. Patient-reported outcomes and complications were also obtained. There were no cases of component loosening or changes in component position during follow-up, with an average follow-up time of 1.7 years. A radiolucent line was identified in one patient in zone 1 at 6 weeks; this was absent at 1 year. Radiographic signs of cup biologic fixation were present in 85% of cases by final follow-up. The average inclination was 45.1 (SD = 4.0), and the average anteversion was 26.9 (SD = 5.2). Patient-Reported Outcomes Measurement Information System scores significantly increased at the final follow-up, and there were no complications in this cohort. This study demonstrated excellent radiographic and clinical outcomes with this novel additive-manufactured acetabular component at early follow-up. Although longer-term follow-up is warranted, this additively manufactured highly porous titanium acetabular component demonstrated excellent biologic fixation and reliable fixation at mid-term follow-up.