Lehai Ni

Lehai Ni

Auto-generated profile, based on publicly available information

Lehai Ni

General Station of Fishery Development and Resource Conservation in Shandong Province, 250013, Jinan, Shandong Province, China

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2026 in Foods
Verified
Journal Article
Open access
PDF file
友张友森 张
友森 张
LNLehai Ni
Lehai Ni
YMYuting Meng
Yuting Meng
CCCuiju Cui
Cuiju Cui
QLQihao Luo
Qihao Luo
WWWeijun Wang
Weijun Wang
Near-infrared (NIR) spectroscopy is a vital non-destructive analytical tool in the food and aquaculture industries. This study pioneers the application of portable NIR spectrometers for evaluating selenium (Se) content in the Pacific oyster (Crassostrea gigas). We developed quantitative and qualitative models to predict selenium levels in oyster tissue, representing a novel application for monitoring trace elements in marine organisms. Quantitative models were developed using partial least squares (PLS) regression on spectra collected with two portable spectrometers (Micro NIR 1700, Micro PHAZIR RX) and a benchtop FT-NIR instrument, with validation via cross-validation and an independent set. Qualitative models were also constructed to categorize Se content into three levels: 0–1, 1–3, and >3 mg/kg. For quantitative analysis, the Micro NIR 1700 model performed robustly in external validation (RP = 0.932; RMSEP = 0.392; RPD = 2.46). The Micro PHAZIR RX model achieved the highest RC (0.988) and the lowest RMSEC (0.233), yet cross-validation indicated a potential risk of overfitting. In contrast, the FT-NIR instrument yielded the best external predictive ability for powdered samples (RP = 0.954, RPD = 2.60), highlighting its high precision under laboratory conditions. For qualitative discrimination, the Micro PHAZIR RX’s classification module achieved a 100% correct recognition rate (AUC = 0.937). The models based on the Micro NIR 1700 and FT-NIR instruments showed cumulative contribution rates (CCR) of 98.61% and 97.59%, respectively, with high performance indices (PI) of 89.3 and 90.2, confirming their effective discrimination capability. The models established in this study enable the rapid, on-site detection of Se content in oyster samples, underscoring the significant potential of portable NIR spectroscopy for selenium analysis in shellfish.

23 September 2026 in Comparative Biochemistry and Physiology Part D: Genomics and Proteomics
Verified
Journal Article
Closed access
JZJingzhao Zhang
Jingzhao Zhang
XZXueyu Zhu
Xueyu Zhu
LNLehai Ni
Lehai Ni
KDKaiyou Deng
Kaiyou Deng
QWQiang Wang
Qiang Wang
GSGuohua Sun
Guohua Sun