Kety Suelyn Ferreira

Kety Suelyn Ferreira

Auto-generated profile, based on publicly available information

Kety Suelyn Ferreira

UFRGS

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2020 in Revista Brasileira de Medicina do Esporte
Verified
Journal Article
Open access
PDF file
KFKety Suelyn Ferreira
Kety Suelyn Ferreira
ATAndré de Oliveira Teixeira
André de Oliveira Teixeira
EBEdineia de Brito
Edineia de Brito
BABruno Cesar Correa Arbiza
Bruno Cesar Correa Arbiza
GPGustavo Puntel
Gustavo Puntel
LSLuis Ulisses Signori
Luis Ulisses Signori
Introduction Resistance exercises (RE) performed at high intensity cause an inflammatory response and electrolyte abnormalities in blood plasma. Objectives To study the plasma electrolyte changes resulting from a high-intensity session of RE in untrained volunteers, and to correlate these with delayed onset muscle soreness (DOMS). Methods Twenty volunteers, aged 26.9 (±4.4) years, underwent an RE session. The workout (leg extension, squat and leg press) consisted of four sets of 10 maximum repetitions. Electrolytes (Na+, K+, Ca2+ e Mg2+) were evaluated before the training (baseline), immediately (0 min), and 30 minutes after the RE. The DOMS was assessed 24 hours after the sessions. Results The Na+ increased immediately after the RE and returned to normal after 30 min (p<0.001). After 30 min, K+ increased compared to baseline levels and immediately after the RE (p<0.001). Ca2+ and Mg2+ levels did not change throughout the study. Changes in Na+ and K+ levels were correlated immediately (r=-0.511; p=0.021) and 30 min (r=-0.455; p=0.049) after RE. Plasma concentrations of Na+ 0 min were correlated (r=-0.520; p=0.018) with the DOMS. Conclusion High-intensity RE in untrained volunteers leads to changes in plasma concentrations of Na+ and K+. Na+ concentrations immediately after RE were related to DOMS; individuals that presented smaller alterations in this electrolyte reported more muscular pain. Level of evidence II; Diagnostic Studies - Development of diagnostic criteria on consecutive patients (with universally applied reference “gold” standard).

20 November 2026 in Child: Care, Health and Development
Verified
Journal Article
Closed access
KFKety Suelyn Ferreira
Kety Suelyn Ferreira
LZLarissa Wagner Zanella
Larissa Wagner Zanella
GNGlauber Nobre
Glauber Nobre
Nadia ValentiniNadia Valentini
Nadia Valentini

26 October 2023 in Fisioterapia Brasil
Verified
Journal Article
Open access
PDF file
KFKety Suelyn Ferreira
Kety Suelyn Ferreira
BABruno Cesar Correa Arbiza
Bruno Cesar Correa Arbiza
LNLéo José Rubin Neto
Léo José Rubin Neto
WGWagner Jesus da Silva Garcia
Wagner Jesus da Silva Garcia
ASAntonio Marcos Vargas da Silva
Antonio Marcos Vargas da Silva
LSLuis Ulisses Signori
Luis Ulisses Signori
Introdução: O laser é empregado no tratamento das úlceras cutâneas, mas para uma maior assepsia e evitar a contaminação de outros pacientes através da caneta é usado o policloreto de vinil (plástico filme - PVC). Objetivo: Avaliar a interferência sobre a luminosidade emitida pelos LaserASERs Hélio-Neônio (He-Ne) e Arseneto-Gálio (Ar-Ga) de diferentes marcas de policloreto de vinil (PVC) e diferentes ângulos de inclinação da caneta. Métodos: As coletas foram realizadas através de fotosensor (DET36A). Utilizando intensidade de 1 J/cm² nas situações: plástico filme em contato direto com a caneta, e 1 cm de distância da caneta, e após acrescentadas as inclinações de 0º, 15º, 30º e 45º. Resultados: As diferentes marcas de plástico filme apresentaram redução média de 12,5% (entre 4% e 26%) para o contato direto e de 14% para o plástico filme posicionado a 1 cm de distância das canetas de He-Ne e Ar-Ga. A inclinação da caneta do He-Ne reduziu luminosidade, sendo que a 0º 12,5% (± 3), a 15º 13% (± 3), a 30º de 16% (± 3) e a 45º esta diminuição foi de 17% (± 3). Na caneta Ar-Ga esta redução foi respectivamente a 0º de 14,7% (± 2), a 15º de 15,5% (± 2), a 30º de 18% (± 2) e a 45º de 20% (± 3) em relação ao controle (sem plástico filme). No Laser Ar-Ga esta redução foi aproximadamente 2% (± 1) menor que na He-Ne nas diferentes inclinações. Conclusão: Os diferentes plásticos filmes reduzem a luminosidade em aproximadamente 13% nas diferentes canetas do laser.