Functional magnetic resonance imaging (fMRI) of the spinal cord is relevant for studying sensation, movement, and autonomic function. Preprocessing of spinal cord fMRI data involves segmentation of the spinal cord on gradient-echo echo planar imaging (EPI) images. Current automated segmentation methods do not work well on these data, due to the low spatial resolution, susceptibility artifacts causing distortions and signal drop-out, ghosting, and motion-related artifacts. Consequently, this segmentation task demands a considerable amount of manual effort which takes time and is prone to user bias. In this work, we (i) gathered a multi-center dataset of spinal cord gradient-echo EPI with ground-truth segmentations and shared it on OpenNeuro https://openneuro.org/datasets/ds005143/versions/1.3.0, and (ii) developed a deep learning-based model, EPISeg, for the automatic segmentation of the spinal cord on gradient-echo EPI data. We observe a significant improvement in terms of segmentation quality compared to other available spinal cord segmentation models. Our model is resilient to different acquisition protocols as well as commonly observed artifacts in fMRI data. The training code is available at https://github.com/sct-pipeline/fmri-segmentation/, and the model has been integrated into the Spinal Cord Toolbox as a command-line tool.
Resting fMRI studies have identified intrinsic spinal cord activity, which forms organised motor (ventral) and sensory (dorsal) resting-state networks. However, to facilitate the use of spinal fMRI in, for example, clinical studies, it is crucial to first assess the reliability of the method, particularly given the unique anatomical, physiological, and methodological challenges associated with acquiring the data. Here we demonstrate a novel implementation for acquiring BOLD-sensitive resting-state spinal fMRI, which was used to characterise functional connectivity relationships in the cervical cord and assess their test-retest reliability in 23 young healthy volunteers. Resting-state networks were estimated in two ways: (1) by extracting the mean timeseries from anatomically constrained seed masks and estimating voxelwise connectivity maps and (2) by calculating seed-to-seed correlations between extracted mean timeseries. Seed regions corresponded to the four grey matter horns (ventral/dorsal and left/right) of C5-C8 segmental levels. Test-retest reliability was assessed using the intraclass correlation coefficient (ICC) in the following ways: for each voxel in the cervical spine; each voxel within an activated cluster; the mean signal as a summary estimate within an activated cluster; and correlation strength in the seed-to-seed analysis. Spatial overlap of clusters derived from voxelwise analysis between sessions was examined using Dice coefficients. Following voxelwise analysis, we observed distinct unilateral dorsal and ventral organisation of cervical spinal resting-state networks that was largely confined in the rostro-caudal extent to each spinal segmental level, with more sparse connections observed between segments (Bonferroni corrected p < 0.003, threshold-free cluster enhancement with 5000 permutations). Additionally, strongest correlations were observed between within-segment ipsilateral dorso-ventral connections, followed by within-segment dorso-dorsal and ventro-ventral connections. Test-retest reliability of these networks was mixed. Reliability was poor when assessed on a voxelwise level, with more promising indications of reliability when examining the average signal within clusters. Reliability of correlation strength between seeds was highly variable, with highest reliability achieved in ipsilateral dorso-ventral and dorso-dorsal/ventro-ventral connectivity. However, the spatial overlap of networks between sessions was excellent. We demonstrate that while test-retest reliability of cervical spinal resting-state networks is mixed, their spatial extent is similar across sessions, suggesting that these networks are characterised by a consistent spatial representation over time.
Functional magnetic resonance imaging (fMRI) of the spinal cord is relevant for studying sensation, movement, and autonomic function. Preprocessing of spinal cord fMRI data involves segmentation of the spinal cord on gradient-echo echo planar imaging (EPI) images. Current automated segmentation methods do not work well on these data, due to the low spatial resolution, susceptibility artifacts causing distortions and signal drop-out, ghosting, and motion-related artifacts. Consequently, this segmentation task demands a considerable amount of manual effort which takes time and is prone to user bias. In this work, we (i) gathered a multi-center dataset of spinal cord gradient-echo EPI with ground-truth segmentations and shared it on OpenNeuro https://openneuro.org/datasets/ds005143/versions/1.3.0 , and (ii) developed a deep learning-based model, EPISeg, for the automatic segmentation of the spinal cord on gradient-echo EPI data. We observe a significant improvement in terms of segmentation quality compared to other available spinal cord segmentation models. Our model is resilient to different acquisition protocols as well as commonly observed artifacts in fMRI data. The training code is available at https://github.com/sct-pipeline/fmri-segmentation/ , and the model has been integrated into the Spinal Cord Toolbox as a command-line tool.
Whole-body dynamic positron emission tomography/computed tomography (WBD-PET/CT) has transformed medical imaging, enabling the fusion between (i) detailed anatomical maps of the human body and (ii) quantitative multi-parametric functional maps of specific biochemical and physiological processes across the human body beyond the semi-quantitative limitations of static PET/CT imaging. Latest developments in systems hardware, particularly with the introduction of long-axial-field-of-view (LAFOV) and Time-of-Flight (TOF) PET scanners and low-dose CT scanners, and in data analysis, primarily with direct parametric PET image reconstruction and Artificial Intelligence, offer unprecedented opportunities towards the wide clinical adoption of the superior quantitative accuracy and precision of WBD-PET/CT imaging overcoming current challenges, such as data acquisition complexity and long scan durations. This review aims to summarize the latest developments, current challenges, and emerging opportunities in WBD-PET/CT, emphasizing its potential to broaden the diagnostic and theranostic role of PET/CT in clinical practice.
Background/Objectives: Single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) is widely used for non-invasive assessment of coronary artery disease under stress and rest conditions. Although deep learning has shown promise for automated SPECT MPI interpretation, most studies focus on single-tracer datasets and do not explicitly account for tracer-dependent variability. This study developed and evaluated a multi-task deep learning framework with tracer-specific prediction heads for patient-level SPECT MPI classification. Methods: A convolutional neural network with a shared feature encoder and tracer-specific heads was implemented using polar map representations from technetium-99m (Tc-99m) and thallium-201 (Tl-201) studies. Transfer learning from ImageNet was applied. Stress-only, rest-only, and dual-input configurations were evaluated using repeated patient-stratified cross-validation and independent testing. Performance was assessed using ROC-AUC and balanced accuracy. Results: For Tc-99m normal versus abnormal perfusion classification, the stress-only model achieved the highest cross-validation AUC (0.88 ± 0.067) and test AUC of 0.88 [0.67–0.99]. For Tl-201 low-risk versus intermediate/high-risk classification, stress-based models achieved the highest cross-validation AUC (0.88 ± 0.051) and test AUC of 0.80 [0.71–0.89], comparable to dual-input models. In both tracer-specific tasks, stress-phase information showed favorable performance, but the endpoints differed and should be interpreted separately. Conclusions: Stress-phase polar maps provided strong discriminative information within this single-center cohort. These findings should be interpreted in a tracer- and task-specific manner supporting stress-phase imaging as an informative input for AI-based SPECT MPI classification while underscoring the need for external validation before broader clinical generalization.