Background: The aim of this study is to investigate the alterations of thalamic nuclei volumes and the intrinsic thalamic network in patients with migraine. Methods: We enrolled 35 patients with migraine without aura and 40 healthy controls. All subjects underwent three-dimensional T1-weighted imaging. The thalamic nuclei were segmented using the FreeSurfer program. We investigated volume changes of individual thalamic nuclei and analyzed the alterations of the intrinsic thalamic network based on volumes in the patients with migraine. Results: Right and left thalamic volumes as a whole were not different between the patients with migraine and healthy controls. However, we found that right anteroventral and right and left medial geniculate nuclei volumes were significantly increased (0.00985% vs. 0.00864%, p = 0.0002; 0.00929% vs. 0.00823%, p = 0.0005; 0.00939% vs. 0.00769%, p < 0.0001; respectively) whereas right and left parafascicular nuclei volumes were decreased in the patients with migraine (0.00359% vs. 0.00435%, p < 0.0001; 0.00360% vs. 0.00438%, p < 0.0001; respectively) compared with healthy controls. The network measures of the intrinsic thalamic network were not different between the groups. Conclusions: We found significant alterations of thalamic nuclei volumes in patients with migraine compared with healthy controls. These findings might contribute to the underlying pathogenesis of the migraine. Trial registration: None.
BACKGROUND AND PURPOSE: Contrast-enhanced 3D-turbo spin-echo (TSE) black-blood sequence has gained attention, as it suppresses signals from vessels and provides an increased contrast-noise ratio. The purpose was to investigate which among the contrast-enhanced 3D T1 TSE, 3D T1 fast-spoiled gradient echo (FSPGR), and 3D T2 FLAIR sequences can better detect cranial nerve contrast enhancement. MATERIALS AND METHODS: Patients with cranial neuritis based on clinical findings (n = 20) and control participants (n = 20) were retrospectively included in this study. All patients underwent 3T MR imaging with contrast-enhanced 3D T1 TSE, 3D T1 FSPGR, and 3D T2 FLAIR. Experienced and inexperienced reviewers independently evaluated the 3 sequences to compare their diagnostic performance and time required to reach the diagnosis. Additionally, tube phantoms containing varying concentrations of gadobutrol solution were scanned using the 3 sequences. RESULTS: For the inexperienced reader, the 3D T1 TSE sequence showed significantly higher sensitivity (80% versus 50%, P = .049; 80% versus 55%; P = .040), specificity (100% versus 65%, P = .004; 100% versus 60%; P = .001), and accuracy (90% versus 57.5%, P = .001; 90% versus 57.5%, P = .001) than the 3D T1 FSPGR and 3D T2 FLAIR sequences in patients with cranial neuritis. For the experienced reader, the 3D T1-based sequences showed significantly higher sensitivity than the 3D T2 FLAIR sequence (85% versus 30%, P < .001; 3D T1 TSE versus 3D T2 FLAIR, 85% versus 30%, P < .001; 3D T1 FSPGR versus 3D T2 FLAIR). For both readers, the 3D T1 TSE sequence showed the highest area under the curve (inexperienced reader; 0.91, experienced reader; 0.87), and time to diagnosis was significantly shorter with 3D T1 TSE than with 3D T1 FSPGR. CONCLUSIONS: The 3D T1 TSE sequence may be clinically useful in evaluating abnormal cranial nerve enhancement, especially for inexperienced readers.