Yingchao Du

Yingchao Du

Auto-generated profile, based on publicly available information

Yingchao Du

Tsinghua University

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2013 in Review of Scientific Instruments
Verified
Journal Article
Closed access
YDYingchao Du
Yingchao Du
LYLixin Yan
Lixin Yan
JHJianfei Hua
Jianfei Hua
QDQiang Du
Qiang Du
ZZZhen Zhang
Zhen Zhang
CTChuanxiang Tang
Chuanxiang Tang
Tsinghua Thomson Scattering X-ray Source (TTX) is the first-of-its-kind dedicated hard X-ray source in China based on the Thomson scattering between a terawatt ultrashort laser and relativistic electron beams. In this paper, we report the experimental generation and characterization of the first hard X-ray pulses (51.7 keV) via head-on collision of an 800 nm laser and 46.7 MeV electron beams. The measured yield is 1.0 × 106 per pulse with an electron bunch charge of 200 pC and laser pulse energy of 300 mJ. The angular intensity distribution and energy spectra of the X-ray pulse are measured with an electron-multiplying charge-coupled device using a CsI scintillator and silicon attenuators. These measurements agree well with theoretical and simulation predictions. An imaging test using the X-ray pulse at the TTX is also presented.

11 March 2021 in Nature Photonics
Verified
Journal Article
Closed access
PDF file
HXHanxun Xu
Hanxun Xu
LYLixin Yan
Lixin Yan
YDYingchao Du
Yingchao Du
WHWenhui Huang
Wenhui Huang
QTQili Tian
Qili Tian
CTChuanxiang Tang
Chuanxiang Tang

6 April 2020 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
ZCZhijun Chi
Zhijun Chi
YDYingchao Du
Yingchao Du
WHWenhui Huang
Wenhui Huang
CTChuanxiang Tang
Chuanxiang Tang

18 March 2021 in Nature Physics
Verified
Journal Article
Closed access
PDF file
YWYipeng Wu
Yipeng Wu
JHJianfei Hua
Jianfei Hua
ZZZheng Zhou
Zheng Zhou
JZJie Zhang
Jie Zhang
SLShuang Liu
Shuang Liu
CJChan Joshi
Chan Joshi

9 January 2023 in Nature Photonics
Verified
Journal Article
Closed access
PDF file
YLYifan Liang
Yifan Liang
ZLZhuoyuan Liu
Zhuoyuan Liu
QTQili Tian
Qili Tian
TLTong Li
Tong Li
XLXiancai Lin
Xiancai Lin
CTChuanxiang Tang
Chuanxiang Tang

26 December 2018 in Physical Review Accelerators and Beams
Verified
Journal Article
Open access
PDF file
LZLianmin Zheng
Lianmin Zheng
JSJiahang Shao
Jiahang Shao
YDYingchao Du
Yingchao Du
JPJohn G. Power
John G. Power
EWEric E. Wisniewski
Eric E. Wisniewski
WGWei Gai
Wei Gai
The solenoid scan is a widely used method for the in-situ measurement of the thermal emittance in a photocathode gun. The popularity of this method is due to its simplicity and convenience since all rf photocathode guns are equipped with an emittance compensation solenoid. This paper shows that the solenoid scan measurement overestimates the thermal emittance in the ordinary measurement configuration due to a weak quadrupole field (present in either the rf gun or gun solenoid) followed by a rotation in the solenoid. This coupled transverse dynamics aberration introduces a correlation between the beam’s horizontal and vertical motion leading to an increase in the measured 2D transverse emittance, thus the overestimation of the thermal emittance. This effect was systematically studied using both analytic expressions and numerical simulations. These studies were experimentally verified using an L-band 1.6-cell rf photocathode gun with a cesium telluride cathode, which shows a thermal emittance overestimation of 35% with a rms laser spot size of 2.7 mm. The paper concludes by showing that the accuracy of the solenoid scan can be improved by using a quadrupole magnet corrector, consisting of a pair of normal and skew quadrupole magnets.