24 February 2025 in Applied Physics Letters
Elastic properties of soft tissues are important indicators for disease progression. Previous studies have utilized mechanical resonance spectroscopy to infer elastic properties of soft tissues by extracting their resonance frequencies. However, the method to accurately obtain the elastic modulus from the resonance frequencies remains inconclusive. In this study, we report a method based on a multi-degree-of-freedom (MDOF) model to determine the Young's modulus of soft tissue samples from the measured resonance spectroscopy. Resonance frequencies of agar tissue phantoms with different elastic properties were obtained, and Young's modulus was calculated using the MDOF-based method. The result was validated by mechanical compression tests and finite element method simulations. The results show that the multi-degree-of-freedom (MDOF)-based method is capable of determining Young's modulus of soft tissue samples with various elasticities and dimensions. This study provides an opportunity to accurately assess the elastic properties of small-sized soft tissue samples.
26 January 2026 in Applied Physics Letters
Assessment of coagulation function is crucial for anticoagulant therapy, surgical procedures, and cardiovascular diseases. Changes in the mechanical properties during coagulation can directly reflect coagulation function. Here, we report a magneto-droplet resonance spectroscopy (MDRS) method to monitor the mechanical property changes of a single drop sample (30 μL) as it transitions from a liquid state to a clot. We utilized a series of low-mass-fraction agarose gel solutions to mimic blood samples with varying coagulation characteristics. We obtained the changes in the resonance frequency of the sample during coagulation and calculated Young's modulus of the coagulated sample using a multi-degree-of-freedom model. The results demonstrate that this method can monitor the whole coagulation process of a single drop sample and effectively distinguish samples with Young's moduli ranging from 0.36 to 2.00 kPa. The MDRS method has the potential to serve as a highly sensitive tool for monitoring the coagulation function of small-sized blood samples.
8 September 2026 in Measurement Science and Technology
Real-time mechanical monitoring of liquid-to-solid phase transitions is essential in materials science and biomedical diagnostics, yet existing instruments face challenges in continuously and nondestructively tracking the complete phase transition process of small-volume samples. Here we present an instrument for monitoring small-volume liquid-to-solid phase transitions based on magnetically driven droplet resonance. By combining phase-sensitive optical coherence tomography (OCT) detection with magnetic excitation using embedded superparamagnetic nanoparticles, the instrument enables continuous measurement of the resonance frequency throughout the entire transition process of a single 30 droplet. We designed a sidewall-free sample base to confine the sample geometry via surface tension, providing consistent vibrational boundary conditions for cross-phase-state measurements. To mitigate electromagnetic interference-induced mechanical noise in the optical detection path under alternating magnetic fields, a non-metallic optomechanical structure was designed, reducing the displacement noise spectral density to below 3 nm . The instrument achieves frequency measurement stability of 0.4 Hz and 0.6 Hz (15 min, standard deviation) for liquid and solid standard samples, respectively. Monitoring of agar gelation and porcine whole blood coagulation demonstrates the instrument’s ability to distinguish distinct phase transition mechanisms. This instrument provides a continuous, non-destructive mechanical monitoring tool for small-volume liquid-to-solid transition research and coagulation function assessment.