5 March 2024 in International Journal of Hydrogen Energy
1 November 2022 in Journal of the Electrochemical Society
Glucose sensor has attracted the attention of academic and industrial researchers because of its broad applications in diabetes management, food quality control, and bioprocess inspection. Compared with enzymatic glucose sensors, non-enzymatic glucose sensors are more relevant because of their stable, sensitive, and low-cost process. The simple and low-cost synthesis of advanced nanomaterials for a non-enzymatic glucose sensor is vital in practical applications. Here, we introduce a facile chemical method for the direct synthesis of nickel(II) hydroxide nanostructures on porous nickel foam (NF) for an electrochemical glucose sensor. The properties of the synthesized material were characterized by field-emission scanning electron microscopy, energy-dispersive X-ray spectroscopy, high-resolution transmission electron microscopy, selected area electron diffraction, and Raman spectroscopy. The fabricated materials were applied for glucose concentration measurement in 0.1 M NaOH by cyclic voltammetry and chronoamperometry. The Ni(OH)2/NF sensor is stable and has excellent sensitivity (12.55 mA mM−1 cm−2) with a low detection limit of 57 μM (S/N = 3) and high selectivity for glucose detection in the presence of common interfering species. The Ni(OH)2/Ni electrode was successfully tested in measuring glucose concentration in real serum samples. The fabricated Ni(OH)2/NF electrode can be used as a low-cost, sensitive, stable and selective platform for non-enzymatic glucose sensors.
1 January 2015 in Journal of Nanomaterials
A triple electrode setup with a Pt pseudo‐reference electrode integrated in a polydimethylsiloxane‐ (PDMS‐) based microchamber was designed and fabricated. The integrated electrodes were deposited onto SiO2/Si substrate by sputtering. The PDMS microchamber was patterned using an SU‐8 mold and sealed with electrodes in oxygen plasma. Polypyrrole nanowires (PPy NWs) were electrochemically grown in situ at an accurate position of the working electrode in the sealed microchamber instead of in an open system. The DNA probe sequences were simply introduced into the channel to form bonds with the nanowires. A detection limit of 20 pM was achieved using a lock‐in amplifier. The electrochemical characteristics produced by the hybridization of DNA strands in the microchamber showed a good signal/noise ratio and high sensitivity. Measurement of the DNA sensor in narrow space also required much less volume of the analytical sample compared with that in an open measuring cell. Results showed that this simple system can potentially fabricate nanostructures and detect bio/chemical molecules in a sealed system.
1 January 2024 in Journal of the Electrochemical Society
Electrochemical glucose sensors, including enzymatic and non-enzymatic sensors, have been considered as quick, accurate, and efficent means for glucose measurement. Recently, non-enzymatic electrochemical glucose sensor based on metal oxides have been paid attention to develop thank to their outstanding behaviours. In most of these studies, metal oxides were synthesized individually and subsequently deposited on the electrode surface using a binder. In this study, we aim at developing a non-enzymatic glucose sensor based on NiO nanoflowers directly grown on a commercial pencil graphite electrode. NiO matetials were deposited on the electrode without a binder via a facile and low-cost chemical procedure. The synthesised materials’ morphologies and components of were characterized by a field emission scanning electron microscopy, energy-dispersive X-ray spectroscopy, and X-ray diffraction analyses. Electrocatalytic performance was recorded by cyclic voltammetry and chronoamperometry. The resulting NiO nanoflowers, characterized by funnel-shaped structures measuring 500–600 nm in diameter and 20 nm in thickness, were formed on the pencil graphite electrode. The fabricated electrode showed a remarkably high sensitivity of 337 μA mM−1 cm−2, a low limit of detection of 4 μM, and good selectivity. The fabricated electrode can be a potential candidate for clinically medical applications.
1 December 2021 in Advances in Natural Sciences: Nanoscience and Nanotechnology
Diabetes is a dangerous chronic disease leading to death. Regular glucose level monitoring in the blood is very important to reduce the risk of diabetes. A lot of methods have been developed to measure the glucose concentration. The non-enzymatic glucose sensor is one of the efficient methods, which has attracted much attention from researchers. In this work, a facile process for the synthesis of NiO nanohives on the surface of nickel foam substrate was reported to apply for the non-enzymatic glucose electrochemical sensing. Morphologies and components of the obtained materials were characterised by field emission scanning electron microscopy (FE-SEM) and energy-dispersive x-ray spectroscopy. FE-SEM images show homogeneous NiO nanohives covering the surface of nickel foam with each cavity diameter of 300–500 nm. Cyclic voltammetry and amperometry were conducted to measure the electrochemical properties of the synthesised NiO/Ni electrodes. The results show that the sensor is highly sensitive (10.08 mA mM −1 cm −2 ) with a low detection limit (7.25 μ A), which is evaluated highly potential to apply for the non-enzymatic glucose electrochemical sensor.
15 April 2024 in Engineering and Technology For Sustainable Development
Non-enzymatic glucose sensors have gained significant attention owing to their potential for accurate and cost-effective glucose detection. Nanomaterials play a pivotal role in enhancing performance of non-enzymatic glucose sensor. In this study, we introduce a novel non-enzymatic glucose sensor based on Ni(OH)2/NF (nickel hydroxide/nickel foam) materials using different pulse voltammetry technique. Chemical precipitation methods have been used to grow Ni(OH)2 nanostructures directly on a nickel foam electrode. The characterization of the synthesized materials was performed through field emission scanning electron microscopy (FESEM), energy dispersive spectroscopy (EDX), and X-ray diffraction (XRD). The performance of the Ni(OH)2/NF-based glucose sensor was evaluated through electrochemical measurements. Nanoscale hive-like structures of Ni(OH)2 with a diameter ranging from 450 to 530 μm and a thickness of 20 nm were formed on the NF surface. The sensor exhibited good performance, displaying a high sensitivity of 8.42 mA mM-1 cm-2 with a low detection limit of 0.84 μM. These results position the synthesized electrode as a promising contender for non-enzymatic electrochemical glucose sensors.