17 September 2019 in Aerosol Science and Technology
The physical, chemical, and biological properties of an aerosol droplet/particle are dependent on the morphology of the droplet/particle itself; for example, a liquid droplet will be processed by oxidants in the gas phase in a fundamentally different way than a solid particle. Additionally, given their small size, aerosol droplets may change phase over timescales in the order of milliseconds (e.g. deliquescence or crystallisation). Thus, ability to rapidly and easily estimate the morphology of a droplet/particle is critical, especially in the interpretation of complex aerosol processes such as spray drying and dissolution. To be reported here is a novel method that uses the forward scattered light (∼32° < θ < ∼58°) passed through a droplet to determine the droplet/particles morphology. The algorithm was developed through the qualitative analysis of over one million individual phase functions of various particle morphologies. The algorithm can differentiate between four different morphologies: homogeneous, core/shell, with inclusions, and non-spherical/inhomogeneous. The algorithm is applicable to droplets between ∼5 to ∼30 microns in radius. The rate of phase analysis is dependent on the rate in which the light scatter can be collected, in the data presented here a particle’s morphology is reported every 10 milliseconds. The accuracy of the phase identification with the algorithm proposed in this work is very high (>90%); its utility is strengthened by the high frequency of the collection of scattered light, which allows an individual droplet to be probed upwards of over 100 times per second. Although not absolute on every phase function analysis, when coupled with repetition and high throughput, the algorithm presented here can be a valuable tool to easily and readily determine particle morphology in dynamic aerosol systems.
29 December 2017 in Aerosol Science and Technology
The nasal aerosol filtration properties of infants 0–3 months old have been quantified through in vitro measurements. Computed tomography (CT) scan data was obtained of seven individuals with ages of 5–79 days. Nasal airway replicas based on these images were manufactured using rapid prototyping. Deposition in the replicas was measured using an electrical low pressure impactor (ELPI) to measure the concentration of aerosol particles in the inertial regime. Comparing the difference in concentration when sampling through the model versus sampling through a blank line gave the deposition fraction. Deposition was measured for particles with aerodynamic diameters between 0.53 and 5.54 μm. Nonlinear least squares curve fitting was performed to collapse intersubject variability and represent the data with a single curve. To achieve satisfactory intersubject variability collapse, a non-dimensional pressure drop, the Euler number (Eu), was required in addition to the Reynolds number (Re) and the particle Stokes number (Stk) where the dimensionless parameters are evaluated with a length scale, D, defined as the airway volume divided by the airway surface area. The equation describing the deposition fraction, η, is η = 1- (14590 / (14590 + Stk1.2201Re1.7742Eu1.5772))0.3687. An analysis of the expected intersubject variability in in vivo deposition was also performed, yielding a method for predicting variance in neonatal nasal airway deposition. Copyright © 2018 American Association for Aerosol Research
30 March 2018 in Aerosol Science and Technology
Experimental studies of particle formation from solution droplets were conducted using a newly developed monodisperse spray drying process. Solutes beclomethasone dipropionate and caffeine were dissolved in ethanol, pressurized hydrofluoroalkane propellant 134a, and mixtures thereof. Solutions were atomized into monodisperse microdroplets using a custom droplet generator installed in a laboratory scale spray dryer, enabling drying and collection of the resulting monodisperse microparticles. The effects of droplet diameter, solution concentration, solvent composition, and drying rate on the physical properties of the dried particles were evaluated. Particle morphology and size were assessed using ultramicroscopy and image analysis of micrographs. Extent of crystallinity and polymorphism were investigated using Raman spectroscopy. The drying temperature was found to have a large effect on the morphology of amorphous beclomethasone dipropionate particles. Particles dried near room temperature were spheroidal to ellipsoidal with prevalent surface concavities and evidence of shell buckling; increasing the drying temperature for fixed droplet size and composition resulted in a transition to more spherical, smooth-surfaced particle morphologies. Crystalline caffeine microparticles were made up of assemblies of multiple crystallites. The measured length and breadth of these crystallites was found to be correlated with the time available for crystal nucleation and growth as calculated using a particle formation model. The results highlight the abilities and limitations of currently available particle formation models in elucidating the relationships between the size, composition, and evaporation rate of drying solution droplets and the physical properties of the resulting particles. The work demonstrates the suitability of monodisperse spray drying as an experimental technique for investigating the fundamentals of particle formation from solution droplets. © 2018 American Association for Aerosol Research
1 January 2016 in Atomization and Sprays
This work describes an atomizer capable of generating monodisperse droplets of high vapor pressure liquids such as HFA227ea and HFA134a. This atomizer is expected to be a useful tool in future fundamental explorations of the mechanics of these highly dynamic aerosols. Hydrofluoroalkanes (HFAs) are the most common propellants in metered dose inhalers (MDIs), which are themselves the most common delivery method for pulmonary disease medications. As a result of the high vapor pressure of these fluids, generation of monodisperse droplets and their study are not possible with previously existing monodisperse atomizers due to fluid flashing when exposed to ambient conditions. The new atomizer uses a piezoelectric transducer to disintegrate the propellant jet, a cooling circuit with a low-temperature limit of -30°C to reduce propellant vapor pressure, and a high-pressure feed system (up to 2.7 MPa) to keep the propellant in the liquid phase, thereby avoiding flash atomization. In the current setup, the diameter of the generated droplets was monitored with a laser scattering system (using Fraunhofer diffraction theory) to optimize the operating parameters of the setup (for example, the actuation frequency and amplitude of the piezoelectric transducer). This monitoring system allowed for the measurement of droplet geometric diameter, spacing, and velocity. The capabilities of the atomizer for generating monodisperse droplets are demonstrated by a case study in which monodisperse dry particles of beclomethasone dipropionate (BDP) are generated using a solution of BDP, ethanol co-solvent, and HFA134a propellant.
24 May 2017 in Aerosol Science and Technology
Pressurized metered dose inhalers (pMDI) produce large numbers of droplets with smaller sizes than 5 μm to treat asthma and other pulmonary diseases. The mechanism responsible for droplet generation from bulk propellant liquid is poorly understood, mainly because the small length scales and short time scales make it difficult to characterize transient spray formation events. This article describes the development and findings of a numerical atomization model to predict droplet size of pharmaceutical propellants from first principles. In this model, the velocity difference between propellant vapor and liquid phase inside spray orifice leads to formation of wave-like instabilities on the liquid surface. Two variants of the aerodynamic atomization model are presented based on assumed liquid precursor geometry: (1) cylindrical jet-shaped liquid ligaments surrounded by vapor annulus; (2) annular liquid film with vapor flow in the core. The growth of instabilities on the liquid precursor surfaces and the size of the subsequently formed droplets are predicted by numerical solutions of dispersion equations. The droplet size predictions were compared with phase doppler anemometry (PDA) data and the predictions were in good agreement with the number mean diameter D10, which is representative of the respirable droplets. The temporal behavior of droplet size production was captured consistently well during the period of the first 95% of the propellant mass emission. The outcome of our modeling activities also suggests that, in addition to saturated vapor pressure of the propellant, its viscosity and surface tension are also key properties that govern pMDI droplet size. © 2017 American Association for Aerosol Research
9 September 2022 in Aerosol Science and Technology
Pressurised metered dose inhalers (pMDI) are one of the most common devices to deliver therapeutic treatment to patients with asthma or COPD. The atomisation mechanism responsible for droplet production is poorly understood because of the short length and timescales involved, making experimental investigations to characterise fluid flow structures and spray formation processes difficult. This article reports the findings of new high-speed and high-resolution imaging and temperature measurements seeking to improve the fundamental understanding of the atomisation mechanism of the pMDI. An annular flow regime of gaseous core in liquid annulus was observed in the orifice. Shock diamonds within the flow, viewed via Schlieren imaging, confirmed experimentally for the first time the choked nature of the orifice exit flow. Propellant formulation flow in the orifice was found to be superheated to a degree that significant flashing and evaporation at the orifice exit is likely to take place. This information points to a hybrid mechanism of predominantly aerodynamic atomisation with significant liquid flashing upon exit from the orifice producing a near instantaneous formation of respirable droplets. Large irrespirable droplets are produced by two mechanisms; breakup of liquid slugs ejected from the orifice, due to unsteady transient fluid structures in the actuator sump and stripping of ligaments from a liquid pool around the orifice exit, which subsequently break up into large droplets in the periphery of the plume. This new understanding will aid development of next generation, high efficiency pMDIs, particularly those employing low global warming potential propellants such as HFA152a or HFO1234ze(E).