Olga V. Astafieva

Olga V. Astafieva

Auto-generated profile, based on publicly available information

Olga V. Astafieva

Kuban State Medical University

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2022 in Radiology - Practice
Verified
Journal Article
Open access
PDF file
MAM. A. Asriyants
M. A. Asriyants
OAO. V. Astafieva
O. V. Astafieva
APA. V. Pomortsev
A. V. Pomortsev
EGE. K. Gordeeva
E. K. Gordeeva
Dirofilariasis is a transmissible zoonotic biohelminthiasis caused by nematodes that parasitize the lymphatic system and subcutaneous tissue. This paper presents cases of dirofilariasis lesions of the soft tissues of the face and eyes.Purpose: to demonstrate the possibility of ultrasonic diagnosis of dirofilariasis of soft tissues of the face.Materials and methods. Dirofilaria can affect the soft tissues of the face, eyes, mammary glands, buttocks. Patients complained of swelling, induration and hyperemia in the soft tissues of the face. Ultrasound was performed, which determined echoes characteristic of helminthic parasites, parasites were removed, the belonging of the macropreparation to dirofilaria type Dirofilaria repens was confirmed by the laboratory of the SES of Krasnodar.Results: the possibilities of ultrasound examination of the eyes and soft tissues were demonstrated, and the characteristic echo signs in dirofilariasis were identified.

18 September 2021 in Medical Visualization
Verified
Journal Article
Closed access
PDF file
MAM. A. Asriyants
M. A. Asriyants
OAO. V. Astafieva
O. V. Astafieva
Spontaneous abortion occur in 15–20% of all detected pregnancies, and 45–70% of all spontaneous miscarriages take place up to 10 weeks. Thrombophilia is one of the main causes of miscarriage and its effect on the course of pregnancy remains poorly understood. In this regard, there is great interest in the problem of diagnosing thrombophilia and further prevention of thrombosis in obstetric practice. Purpose . Compare the parameters of volumetric blood flow in the chorion with different types of trophoblastic blood flow disturbance in pregnant women with thrombophilia in the first trimester for their quantitative verification. Materials and methods . The study included 129 pregnant women at the 7th to 10th week of gestation with a diagnosis of thrombophilia and a control group - pregnant women with a normal course of this pregnancy and a successful outcome of past pregnancies. The patients were divided into III clinical groups: I. Pregnant women with a normal course of this pregnancy and a successful outcome of past pregnancies (n = 33) – comparison group; II. Pregnant women with thrombophilia, in whom current pregnancy occurred on anticoagulant therapy (n = 28); III. Pregnant women with thrombophilia without taking anticoagulant drugs before registration of pregnancy (n = 68). Ultrasound was performed on Voluson E8 and S8 machines. All pregnant women underwent transabdominal and transvaginal ultrasound in B-mode, in color-doppler (CD) mode, and volumetric reconstruction of chorion was performed using the VOCAL program. In B-mode, the state of the embryo and extraembryonic structures were examined. The identification of trophoblastic vessels was carried out using the CD – region of interest was placed in the trophoblast area detected in B-mode, size and shape was adapted for a particular section. Using three-dimensional echography, the chorion volume was performed. The degree of blood supply in chorionic volume were calculated; vascularization index (VI), flow index (FI) and perfusion index (VFI) were displayed on a histogram with quantitative indicators. Results In the CD mode, the types of trophoblastic blood flow were identified in the chorionic vessels: 1) continuous type – blood flow loci are continuously identified over the entire area of the basal surface of the trophoblast; 2) intermittent type – blood flow loci are unevenly identified along the basal surface of the trophoblast; 3) single loci – single blood flow loci are identified along the basal surface of the trophoblast; 4) lack of blood flow – blood flow loci are not determined along the basal surface of the trophoblast. Assessment of the quantitative parameters of the volumetric blood flow was used in the corresponding type of blood flow to verify the classification of types of trophoblastic blood flow in the CD mode. Statistical analysis of the volumetric blood flow indices using three-dimensional chorionic reconstruction showed a high degree of reliability (p < 0.0001) in the VI and VFI values between all corresponding types of blood flow. Discussion . High incidence of spontaneous abortion and the significant role of thrombophilia in this pathology leads to necessity of expanding the research in this area. There has been a lot of research done over the past decade. The quantitative threshold values of the resistance indices in the chorionic vessels were calculated using pulse-wave Doppler, the chorionic blood supply indices were determined using volumetric reconstruction for various pathologies. However, we have not previously met the classification of chorionic blood supply in the CD mode. This technique is very simple to perform and is a highly informative for predicting miscarriage in the first trimester. For the first time, we proposed the above classification of trophoblastic blood flow; for the first time, we proved the reliability of the classification developed by us using the method of volumetric reconstruction of the chorion with an assessment of trophoblastic blood flow, which allows us to recommend its use when writing a protocol for ultrasound of the fetus in the first trimester in pregnant women with thrombophilia. Conclusion . The classification of trophoblastic blood flow was verified by three-dimensional echography with quantitative indicators of the volumetric blood flow of the trophoblast vessels, with a high degree of reliability (p < 0.001) which to indicates the reliability of this classification. It can be recommended to conduct a multicenter study for investigating fetal ultrasound with the additional use of the CD in the first trimester in pregnant women with a diagnosis of thrombophilia.

7 April 2026 in Digital Diagnostics
Verified
Journal Article
Open access
PDF file
APAlexey V. Pomortsev
Alexey V. Pomortsev
JDJulia Yu. D’YAchenko
Julia Yu. D’YAchenko
MMMariam A. Matosian
Mariam A. Matosian
EAEkaterina A. Arutyunyan
Ekaterina A. Arutyunyan
MAMilena A. Arutyunyan
Milena A. Arutyunyan
КНКартич Алексей Николаевич
Картич Алексей Николаевич
Timely detection of congenital malformations of the fetus remains one of the urgent problems of modern prenatal diagnostics. The survival rate of children, the volume and quality of medical care during treatment and rehabilitation directly depend on early and reliable diagnosis. In modern medicine, prenatal diagnosis is an obligatory complex of medical manipulations, various methods of examining patients to monitor the health of a pregnant woman and fetus. Ultrasound is one of the main methods of medical imaging, as it is non-invasive, safe and informative in the examination of pregnant women. Recently, technologies for processing video files and static images using artificial intelligence have been actively used in ultrasound diagnostics. This review collects and analyzes 52 sources by both foreign and domestic authors. The list of sources used includes domestic and foreign original research in the field of the use of artificial intelligence in prenatal diagnostics, systematic reviews, methodological manuals, practical and clinical recommendations, and monographs. PubMed, Google Scholar, and eLibrary were selected as search engines. A comprehensive search was performed using keywords in Russian and English: искусственный интеллект / artificial intelligence, ультразвуковая диагностика / ultrasound diagnostics, нейросеть / neural network, плод / fetus, and врождённые пороки развития / congenital malformations. The search depth was 6 years (from 2020 to 2025). The review revealed the obvious advantages of using neural network systems in prenatal diagnostics. Automation and standardization of fetal ultrasound examination make it possible to create a real-time neural network analysis algorithm and ensure quality control of the resulting echographic images. The undoubted advantages of artificial intelligence technologies are minimizing the variability of instrumental diagnosis between different specialists and reducing the time to obtain the “correct” echographic section. In addition, artificial intelligence enables the automatic identification of standard scanning planes, “recognition” of anatomical structures, and biometric measurements in the fetus. There are problems associated with the introduction of modern intelligent decision support systems in healthcare around the world and in Russia in particular. The most pressing issues are medical, legal, and ethical issues, the problem of lack of transparency in decision-making (“black box”), leading to skepticism among specialists, and poor effectiveness in diagnosing rare anomalies due to the small amount of training material. Today, modern computer technologies with the function of neural network analysis in prenatal diagnostics should be considered as a powerful auxiliary tool for doctors.

1 March 2026 in Innovative Medicine of Kuban
Verified
Journal Article
Open access
PDF file
YGYu. V. Goloshchapova
Yu. V. Goloshchapova
DLD. V. Lukyanenko
D. V. Lukyanenko
OMO. M. Meshcheryakova
O. M. Meshcheryakova
AKA. N. Katrich
A. N. Katrich
AKA. A. Khalafyan
A. A. Khalafyan
ЮГЮ. В. Голощапова
Ю. В. Голощапова
Objective : To develop high-accuracy neural network model for the diagnosis and prediction of the severity of mitral regurgitation as assessed by echocardiography. Materials and methods : A total of 80 patients were divided into two groups: Group 1 included 42 patients with an eccentric mitral regurgitation jet, and Group 2 included 37 patients with a central mitral regurgitation jet. All patients underwent transthoracic echocardiography with assessment of mitral regurgitation severity based on the percentage ratio of the regurgitation jet area to the left atrial area. The vena contracta, proximal isovelocity surface area radius, and the magnitude of the horizontal color Doppler expansion artifact were measured. The effective regurgitant orifice area and mitral regurgitant volume were calculated. Results . A neural network model was developed that predicts “moderate” and “severe” forms of mitral regurgitation based on echocardiography data with highest possible accuracy (100%). The accuracy for predicting the “mild” form was slightly lower (83.33%).