22 June 2015 in IEEE Transactions on Power Electronics
This paper presents a new trend in the transportation industry to adopt the multilevel inverter-based propulsion systems and gives the design procedure of a new DC/AC three-phase six-level inverter for powering the rail metro cars. The proposed inverter is based on the multilevel converter as it possesses much lower component voltage stress compared with the pulsewidth-modulated (PWM) topologies. Space vector pulsewidth modulation (SVPWM) with back-to-back clamped diode voltage modulation operation is used to achieve voltage regulation and high efficiency at any loading condition. Zero-current-switching operation is achieved without using an auxiliary circuit, which leads to minimum switching losses. The novelty of the proposed inverter lies within the proposed control methodology, which uses a new switching pattern that guarantees a modified SVPWM to eliminate the unwanted harmonics from the output voltage. The new algorithm is developed using numerical iterative solution using the Newton-Raphson technique that was downloaded to the processor using digital signal processing developed code. The mathematical model is simple but proven to be effective. As a result, a higher operating efficiency at full load of 98.5% is achieved as compared to previous efficiency of 97%. Analytical, simulation, and experimental results of a 1500 Vdc/700 Vac 400-kW converter are presented to offer the proof of concept. The converter provides real estate savings for the train under floor layout, higher operating efficiency as well as better cost price than the conventional two-level PWM hard-switched converters.
1 December 2016 in IEEE Transactions on Power Electronics
This paper presents, initially, a systematic derivation of extended first harmonic approximation (FHA) analysis and, later, a comprehensive time-domain (T-D) analysis to study series-series compensated inductive power transfer systems with a diode bridge rectifier. Further, the paper shows that both FHA and T-D methods predict four mutually-exclusive and collectively-exhaustive modes of operation. Explicit criteria for each operation mode and formulae for mode boundaries are derived and it is concluded that FHA can explain three of four modes. The proposed T-D analysis is capable of describing the quantitative behavior of the system in all four operation modes with closed-form equations for all the mode boundaries. This analysis provides an objective basis to assess the accuracy of FHA predictions under the entire operating conditions. Quantitative comparison of key variables revealed that the FHA results can be unacceptably inaccurate for certain operating points. It is shown that the T-D approach provides a comprehensive design base for series-series compensated inductive power transfer without a need to know the load value. The T-D predictions are validated by experiment. A mathematical design calculator tool is also provided to the reader to visualize the mode boundaries, all the waveforms and the numerical results from both methods.
8 May 2014 in Canadian Journal of Electrical and Computer Engineering
A new method to model the end effect for single-sided short-primary linear induction motors (LIMs) is developed by considering the effect of nonzero leakage inductance of the secondary. The well-established equivalent circuit model-introduced by Duncan in the 1980s-is improved by taking nonzero leakage inductance into account. This new approach closes the gap between predictions and test results of a transit LIM. It also allows for reliable model utilization in engineering practice. The analytical predictions are verified with the field test data collected from a full-scale LIM designed for public transit systems.
12 September 2016 in IEEE Transactions on Transportation Electrification
This paper introduces a novel engineering feasibility study for developing a future hybrid metro system, for the first time in Canada, that is of extremely low cost and independent of the utility grid. This system will eliminate the need of the rail cars to rely on the track substations and consequently the utility grid. This paper is based on the load profiles provided by Bombardier Transportation for its advanced rapid transit train running in Vancouver, BC, Canada. Simulation was performed for propulsion with and without auxiliary power with the assumption of an average power of 40 kW. To size the system for the worst case scenario, the regeneration power will not be taken into account in case the propulsion cuts off during regenerative braking. The subsystem modules described in the model are listed for reference purposes. The hydrogen consumption and storage are also calculated for each case with the tank options listed for each energy storage option. Furthermore, an analysis platform is being provided for a sound design of a hybrid metro car for the first time in North America. This systematic modular approach can be easily applied to any transit system worldwide. A successful design for a fuel cell hybrid train is given, which is fully independent on the electricity from the grid. The elimination of the wayside substations system, which is 90% of the cost of the transit system, presents huge initial and running cost savings and makes the rail car ridership very inexpensive.
1 January 2015 in Canadian Journal of Electrical and Computer Engineering
High reliability and cost effectiveness of power electronic components have resulted in high level of interest in wireless power transfer techniques among academic and industrial professionals. Since the major interest is directed toward automotive and rail industries for electromagnetically coupled fast battery charging systems, a special transformer with a large gap and relatively large leakage inductance is used. To achieve desired voltage and power levels with a reasonable compact-sized transformer, high frequencies in the order of 20-100 kHz are preferred, producing high levels of reactive power, which limit the amount of transferred power and efficiency if not compensated. There are four basic transformer compensation topologies reported in the literature, each being the combination of series and/or parallel compensations. This paper presents all four topologies and the associated input-to-output dependence based on a Boucherot bridge model of a transformer. Analytical modeling predictions are supported by finite-element analysis results to provide the proof of conceptual finding of this technology. Design procedures for each of the four configurations are presented in detail. A comparison study that highlights the merits and demerits of each configuration is given to help determine the appropriateness of each transformer configuration to a particular application.