1 May 2019 in AIP Advances
In order to apply the multichamber structure to DC lines, it’s necessary to know the principle of arc quenching and the arc development process in the multichamber structure. Through analyzing the quenching characteristics of DC arc and establishing the 2-D geometric model of multichamber structure based on the magnetohydrodynamics theory in COMSOL Multiphysics simulation platform, this paper reveals and explains the principle of arc quenching in the multichamber structure. The simulation result shows that the strong self-expanding airflow which caused by the instantaneous temperature rise in the chambers can cut off the arc channel and block the energy supply of the arc. Then the Impulse-DC arc quenching test is carried out to verify the arcing performance of the improved multichamber structure. The arc is finally extinguished at 1.5ms, which manifests that the improved device can effectively suppress DC arc development.
1 March 2020 in AIP Advances
To reduce the damage from the power frequency follow current of distribution lines, a multi-fracture compression airflow arc-extinguishing structure is studied. The structure is mainly composed of a compression tube, a metal electrode, and metal connection fittings, and the multi-fracture compression airflow arc-extinguishing body is formed by the combination of packaging and insulation fittings. The body and the air gap are parallel to both ends of the insulator. When lightning strikes, the internal short gap of the main body and the air gap break down, and the lightning arc enters the arc-extinguishing body through the breakdown channel. In the structure, the arc is compressed by force to form internal and external gradients of temperature and to produce jet airflow. The jet airflow acts on the subsequent power frequency follow current arc, which is suppressed and extinguished. In this paper, a model coupling an arc and a compressed jet airflow in a multi-fracture compression airflow arc-extinguishing structure is established theoretically and simulated by simulation software. Finally, a power frequency follow current interruption test is carried out. The simulation results show that a high-speed airflow of 600 m/s is formed around the fracture at approximately 0.99 ms, and the airflow is proportional to the rate of temperature variation. The test results show that the power frequency follow current of 1.289 kA is cut off within approximately 3 ms without a reburning phenomenon. The effect of power frequency follow current interruption is obvious in the structure.
1 June 2020 in AIP Advances
To study the process by which an explosive high-speed airflow extinguishes an arc and the characteristics of arc dielectric recovery in a semienclosed space, this study investigates the principles and processes of the formation, development, and extinction of an arc under the action of a high-speed airflow. When the impact arc occurs in a semienclosed arc-extinguishing chamber, the high-speed air suppresses arc development. Due to the high-speed airflow, the arc cools at an accelerated rate; the arc energy weakens, breakpoints occur, and the continuity of the arc energy channel is broken, preventing the arc from forming in the arc-extinguishing chamber and extinguishing it. This article employs AUTODYN software to establish a model for high-speed airflow arc extinguishing in a semienclosed space and then reveals a process by which a high-speed airflow extinguishes an arc in such a space. To verify whether a high-speed airflow can extinguish an arc, we conduct experiments in which high-speed airflow extinguishes a large impact arc and a power frequency arc. We recorded the arc extinguishing process with high-speed and ordinary cameras. The time taken to extinguish the arc is approximately 7 ms, and the arc does not regenerate.