Yehia Salah Eldin Mostafa

Yehia Salah Eldin Mostafa

Auto-generated profile, based on publicly available information

Yehia Salah Eldin Mostafa

Chairman and Professor of Ophthalmology, Kasr Alainy Faculty of Medicine, Cairo University, Giza, Egypt

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2020 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
MSMohamed Karim Sidky
Mohamed Karim Sidky
DHDina Hossam Hassanein
Dina Hossam Hassanein
SESherif A Eissa
Sherif A Eissa
YSYehia M Salah
Yehia M Salah
NLNancy M Lotfy
Nancy M Lotfy
Purpose: To report the prevalence of subclinical keratoconus (KC), and KC suspects, in pediatric Egyptian population with astigmatic error ≥ 2 diopters (D), with the use of CSO Sirius tomographer. Methods: A cross-sectional study that included all the children aged 6– 18 years with an astigmatic error of ≥ 2 D who attended the pediatric ophthalmology clinic for routine checkups during the period between March 2017 and December 2017 was done. All subjects underwent comprehensive ophthalmic examination, and corneal imaging using CSO Sirius instrument, a pentacam with Scheimpflug technology. Results: There were 547 subjects enrolled in our study. Mean age was 11.34 ± 3.03 (range 6– 18) years. There were 278 subjects (50.8%) between 6 and 12 years, and 269 subjects (49.2%) between 12 and 18 years. Males represented 48.4% and females represented 51.6% of patients. Among all the subjects, there were 26 (4.8%) KC patients, 24 (4.4%) KC suspects, and 497 (90.9%) were normal. Conclusion: Prevalence of subclinical KC among pediatric age group with astigmatism is relatively high, hence the importance of corneal tomography screening of children with astigmatic error ≥ 2 D.

20 January 2025 in International Ophthalmology
Verified
Journal Article
Closed access
PDF file
SLSihem Lazreg
Sihem Lazreg
AAAhmed Hassan Assaf
Ahmed Hassan Assaf
AAAhmed Mostafa Abdelrahman
Ahmed Mostafa Abdelrahman
MHMohamed Hassan Hosny
Mohamed Hassan Hosny
MSMohamed Shafik Shaheen
Mohamed Shafik Shaheen
YMYehia Salah Eldin Mostafa
Yehia Salah Eldin Mostafa

1 April 2021 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
RGRania E Gad
Rania E Gad
MHMohamed Hassan Hosny
Mohamed Hassan Hosny
RARania A Ahmed
Rania A Ahmed
ASAhmed M Sherif
Ahmed M Sherif
YEYehia Salah Eldin
Yehia Salah Eldin
Purpose of the Study: To compare visual outcome, higher order aberrations (HOAs) of topography guided and Q value adjusted ablation in the fellow eye of patients undergoing photorefractive keratectomy (PRK) for the correction of myopia and myopic astigmatism. Methods: Prospective randomized controlled interventional clinical study. The eyes of 52 patients undergoing PRK for myopia and astigmatism were included, that is, 104 eyes in total. In each patient, eyes were randomly allocated to group I: one eye received topography guided PRK using Contoura ablation software, or group II: the other eye received Q value adjusted PRK using Custom Q ablation software. Follow-Up: Six months. Results: At the end of 6 months, LogMAR UDVA was − 0.04 ± 0.12 and − 0.05 ± 0.11 (p = 0.688), while LogMAR CDVA was − 0.06 ± 0.09 and − 0.06 ± 0.1 in group I and group II, respectively (p = 0.972). Both groups showed a progressive oblate shift with time. This oblate shift was insignificantly less in group I by Topolyzer at 6mm, 15° and 30° at 6 months (p = 0.102, p = 0.138, p = 0.245, respectively). Topolyzer identified a significant difference between the change in coma and trefoil in both groups at 6 months (p< 0.001 and p = 0.001, respectively). This was caused by the significant worsening of coma in group II (p< 0.001) and the significant improvement of trefoil in group I (p = 0.007). No significant difference was found between groups in the change of ISV or ABR (p = 0.955 and 0.982, respectively). Ablation depth is a significant predictor of ΔQ at 6mm, 15° and 30° (p = 0.009, 0.039 and 0, respectively). No significant difference was found in the Strehl ratio or contrast sensitivity, although they were insignificantly better in group I (p = 0.785 and p = 0.745, respectively). Conclusion: TG PRK and CQ PRK yielded similar results regarding UDVA, CDVA, MRSE, safety, predictability and contrast sensitivity. Both groups showed a progressive oblate shift, which was less in the TG group but the difference was statistically insignificant. TG PRK showed significantly improved trefoil HOA as compared to CQ PRK.