Xin Wang

Xin Wang

Auto-generated profile, based on publicly available information

Xin Wang

Echocardiography Medical Center Beijing Anzhen Hospital Capital Medical University Beijing China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2022 in Prenatal Diagnosis
Verified
Journal Article
Closed access
XWXin Wang
Xin Wang
TYTing‐Yang Yang
Ting‐Yang Yang
YZYing‐Ying Zhang
Ying‐Ying Zhang
XLXiao‐Wei Liu
Xiao‐Wei Liu
YZYe Zhang
Ye Zhang
YHYihua He
Yihua He

1 June 2021 in Echocardiography
Verified
Journal Article
Closed access
PDF file
XWXin Wang
Xin Wang
JLJing‐Jing Liu
Jing‐Jing Liu
JHJian‐Cheng Han
Jian‐Cheng Han
LSLin Sun
Lin Sun
YZYe Zhang
Ye Zhang
YHYihua He
Yihua He

27 December 2019 in Echocardiography
Verified
Journal Article
Closed access
PDF file
XWXin Wang
Xin Wang
LSLin Sun
Lin Sun
XLXiao‐Wei Liu
Xiao‐Wei Liu
JSJian‐Feng Shang
Jian‐Feng Shang
YHYihua He
Yihua He

10 September 2021 in Fetal Diagnosis and Therapy
Verified
Journal Article
Closed access
PDF file
XWXin Wang
Xin Wang
SCSong Chen
Song Chen
PTPeng Tu
Peng Tu
XLXiaowei Liu
Xiaowei Liu
XZXiaohang Zhang
Xiaohang Zhang
YHYihua He
Yihua He
Objective: The aim of the study was to evaluate whether fetal ultrasound could determine bronchial isomerism and distinguish left isomerism from right isomerism. Methods: We identified 110 healthy fetuses and 28 fetuses with isomerism. The outer angle between the tracheal midline and the inner margin of the bronchus is measured. The bronchial angles and the ratio of left/right bronchial angle were used to differentiate bronchial morphology and confirm the presence of bronchial isomerism in pathological cases. Results: The normal angles of the left and right bronchi were 146.98° (95% CI, 145.15–147.81°) and 167.37° (95% CI, 166.30–168.44°), separately. The cutoff bronchial angle of 156.5° was used to distinguish left bronchus from right bronchus. The bronchial isomerism could be identified in all pathological cases by autopsy and bronchial-atrial concordance occurred in 27 pathological cases (96.4%). In 21 pathological cases, the bilateral bronchial angle was 156.5 differentiated left from right isomerism, respectively. The ratio of the left/right bronchial angle of >0.935 identified 92.9% (26/28) of all pathological cases, with a sensitivity of 89.7%. Conclusions: Fetal ultrasound can detect the bronchial morphology and the presence of bronchial isomerism in fetuses with isomerism according to bronchial angles and the ratio of left/right bronchial angle.