1 October 2018 in Earth and Planetary Science Letters
20 October 2016 in Geophysical Journal International
Event-pair double-difference (DD) earthquake location method, as incorporated in hypoDD, has been widely used to improve relative earthquake locations by using event-pair differential arrival times from pairs of events to common stations because some common path anomalies outside the source region can be cancelled out due to similar ray paths. Similarly, station-pair differential arrival times from one event to pairs of stations can also be used to improve earthquake locations by cancelling out the event origin time and some path anomalies inside the source region. To utilize advantages of both DD location methods, we have developed a new double-pair DD location method to use differential times constructed from pairs of events to pairs of stations to determine higher-precision relative earthquake locations. Compared to the event-pair and station-pair DD location methods, the new method can remove event origin times and station correction terms from the inversion system and cancel out path anomalies both outside and inside the source region at the same time. The new method is tested on earthquakes around the San Andreas Fault, California to validate its performance. From earthquake relocations it is demonstrated that the double-pair DD location method is able to better sharpen the images of seismicity with smaller relative location uncertainties compared to the event-pair DD location method and thus to reveal more fine-scale structures. In comparison, among three DD location methods, station-pair DD location method can better improve the absolute earthquake locations. For this reason, we further propose a hybrid double-pair DD location method combining station-pair and double-pair differential times to determine accurate absolute and relative locations at the same time, which is validated by both synthetic and real data sets.
21 March 2019 in Nature Communications
Seismic tomography provides unique constraints on the morphology, the deformation, and (indirectly) the rheology of subducting slabs. We use teleseismic double-difference P-wave tomography to image with unprecedented clarity the structural complexity of the Izu-Bonin slab. We resolve a tear in the slab in the mantle transition zone (MTZ) between 26.5° N and 28° N. North of the tear, the slab is folded in the MTZ. Immediately above the fold hinge, a zone of reduced P-wavespeed may result from viscous dissipation within an incipient shear zone. To the south of the tear, the slab overturns and lies flat at the base of the MTZ. The ~680 km deep 2015 Bonin earthquake (Mw~7.9) is located at the northernmost edge of the overturning part of the slab. The localised tearing, shearing and buckling of the Izu-Bonin slab indicates that it remains highly viscous throughout the upper mantle and transition zone.
7 May 2021 in Nature Geoscience
21 November 2018 in Pure and Applied Geophysics
13 January 2021 in Geophysical Journal International
Knowledge of attenuation structure is important for understanding subsurface material properties. We have developed a double-difference seismic attenuation (DDQ) tomography method for high-resolution imaging of 3-D attenuation structure. Our method includes two main elements, the inversion of event-pair differential |${t^*}$| (|$d{t^*}$|) data and 3-D attenuation tomography with the |$d{t^*}$| data. We developed a new spectral ratio method that jointly inverts spectral ratio data from pairs of events observed at a common set of stations to determine the |$d{t^*}$| data. The spectral ratio method cancels out instrument and site response terms, resulting in more accurate |$d{t^*}$| data compared to absolute |${t^*}$| from traditional methods using individual spectra. Synthetic tests show that the inversion of |$d{t^*}$| data using our spectral ratio method is robust to the choice of source model and a moderate degree of noise. We modified an existing velocity tomography code so that it can invert |$d{t^*}$| data for 3-D attenuation structure. We applied the new method to The Geyser geothermal field, California, which has vapour-dominated reservoirs and a long history of water injection. A new Qp model at The Geysers is determined using P-wave data of earthquakes in 2011, using our updated earthquake locations and Vp model. By taking advantage of more accurate |$d{t^*}$| data and the cancellation of model uncertainties along the common paths outside of the source region, the DDQ tomography method achieves higher resolution, especially in the earthquake source regions, compared to the standard tomography method using |${t^*}$| data. This is validated by both the real and synthetic data tests. Our Qp and Vp models show consistent variations in a normal temperature reservoir that can be explained by variations in fracturing, permeability and fluid saturation and/or steam pressure. A prominent low-Qp and Vp zone associated with very active seismicity is imaged within a high temperature reservoir at depths below 2 km. This anomalous zone is likely partially saturated with injected fluids.