Hoorieh Bashizadeh Fakhar

Hoorieh Bashizadeh Fakhar

Auto-generated profile, based on publicly available information

Hoorieh Bashizadeh Fakhar

Assistant Professor, Department of Oral and Maxillofacial Radiology, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2016
Verified
Journal Article
Open access
SKSedigheh Khedmat
Sedigheh Khedmat
AAAbbas Azari
Abbas Azari
ASAhmad Reza Shamshiri
Ahmad Reza Shamshiri
MFMehdi Fadae
Mehdi Fadae
HFHoorieh Bashizadeh Fakhar
Hoorieh Bashizadeh Fakhar
The aim of this in vitro study was to compare the efficacy of ProTaper retreatment (ProTaper R) and Mtwo retreatment (Mtwo R) files in removing gutta-percha and GuttaFlow from endodontically treated straight root canals. The root canals of 60 human mandibular single-rooted premolars were prepared and randomly divided into two groups (n=30). In groups A and B the root canals were obturated using lateral condensation of gutta-percha plus AH 26 and GuttaFlow, respectively. The canal orifices were temporarily sealed and the roots were incubated for 3 months at 37ºC and 100% humidity. Primary cone-beam computed tomography (CBCT) images were taken after incubation period. The specimens in each group were randomly divided into two subgroups (n=15). ProTaper R files (D1, D2, and D3) were used in groups A1 and B1 while Mtwo R files (25/0.05 and 15/0.05) were used in groups A2 and B2. The time required to extirpate the root filling was also recorded. After retreatment, another CBCT scan was taken at the same position. The volume of remaining filling materials inside the canals was calculated before and after retreatment. The data was analyzed using the two-way ANOVA and independent t-test. The remaining filling materials in the canals treated with ProTaper were less than Mtwo. The remaining volume of GuttaFlow was less than gutta-percha regardless of the system applied. Mtwo R files removed root fillings faster than ProTaper R. ProTaper R removed filling material more efficiently compared to Mtwo R which required less time to remove root filling material.

25 June 2016 in Iranian Journal of Radiology
Verified
Journal Article
Open access
PDF file
MHMohammadhashem Hoseini
Mohammadhashem Hoseini
SZSara Zamaheni
Sara Zamaheni
HFHourieh Bashizadeh Fakhar
Hourieh Bashizadeh Fakhar
FAForough Akbari
Forough Akbari
JCJavad Chalipa
Javad Chalipa
ARAfsaneh Rahmati
Afsaneh Rahmati
Background: Prediction of skeletal growth is necessary for growth modification and surgical orthodontic treatments and is usually done by assessing skeletal maturity indicators in hand-wrist radiographs. The use of growth stages of cervical vertebrae in lateral cephalograms has been suggested to avoid overexposure. Objectives: This study seeks to assess the degree of agreement between hand-wrist and cervical vertebrae maturation stages for skeletal age determination and prediction of the peak growth spurt (PGS). Patients and Methods: This cross-sectional study was conducted with 67 boys and 66 girls between 8 and 18 years of age, divided into 11 age groups; 266 hand-wrist radiographs and lateral cephalograms were obtained and analyzed. Hand-wrist maturation stages were evaluated according to the Grave and Brown, Bjork system (stages 1 - 9). The cervical vertebral maturation stage (CVMS) was determined on lateral cephalograms based on a system described by Baccetti et al. (CVMS 1-5). To apply the Cohen’s kappa index, the stages of growth were reduced to 5 intervals (A - E) to relate the 5 CVMS to the 9 stages of Bjork hand-wrist analysis. Results: In all age groups, the skeletal maturity stages of the hand and wrist bones and the cervical vertebrae of the girls were ahead of the boys. Cohen’s kappa test revealed a low level of agreement between the two methods [Kappa (95% CI) = 0.312 (0.290 - 0.377)]; concordance was slightly higher in males (K = 0.33 for males versus 0.27 for females). Evaluation of concordance coefficients between the stages determined by the two methods indicated the highest concordance in 8- and 9-year-olds and the lowest in 12- and 14-year-olds. The level of agreement between the two methods was only acceptable in 8- and 9-year-olds of both genders and 10-year-old boys. The level of agreement between the two methods in other age groups was not acceptable. Conclusion: The level of agreement between the two methods was low; thus, they cannot be used alternatively to estimate patients’ skeletal age or to predict the PGS. This may be due to the effect of different maturation levels (influenced by the environment, ethnicity, and gender) on the agreement between methods for skeletal age determination. Keywords: Growth; Hand; Wrist; Cervical Vertebrae; Skeletal Age

1 February 2011 in Dental Traumatology
Verified
Journal Article
Closed access
PDF file
MTMaryam Tofangchiha
Maryam Tofangchiha
MBMahin Bakhshi
Mahin Bakhshi
HFHoorieh Bashizadeh Fakhar
Hoorieh Bashizadeh Fakhar
MPMehrdad Panjnoush
Mehrdad Panjnoush

1 June 2016
Verified
Journal Article
Open access
MPMehrdad Panjnoush
Mehrdad Panjnoush
YKYasaman Kheirandish
Yasaman Kheirandish
PKPooneh Mohseni Kashani
Pooneh Mohseni Kashani
HFHoorieh Bashizadeh Fakhar
Hoorieh Bashizadeh Fakhar
FYFarzan Younesi
Farzan Younesi
MMMaysa Mallahi
Maysa Mallahi
The aim of this study was to assess the effect of tube current, kilovoltage peak (kVp), metal type, and the position of metal objects on metal artifacts in cone-beam computed tomography (CBCT) images. Titanium and cobalt-chromium rods were fabricated and placed in a dry human mandible. Samples were scanned using a Promax 3D CBCT unit with different milli-amperages and kVp. The artifacts induced by metal objects were evaluated using the Image J software in four regions of interest (ROIs) on each image. A higher kVp decreased artifacts of the buccal surface of the rods in 97% of the cases (P=0.046) but did not affect the severity of artifacts between the two metal objects (P>0.05). Increasing the tube current had no effect on metal artifacts in 93% of the cases (P>0.05). Artifacts induced by a cobalt-chromium alloy were more severe than those with titanium (P<0.001). Artifacts were more intense in the buccal surface of anterior rods compared to the posterior rods (P<0.003). Tube voltage, metal type and the position of metal objects affected the severity of metal artifacts on CBCT images. The metal type had the greatest effect on metal artifact intensity in this study.

1 August 2016
Verified
Journal Article
Open access
HFHoorieh Bashizadeh Fakhar
Hoorieh Bashizadeh Fakhar
MMMysa Mallahi
Mysa Mallahi
MPMehrdad Panjnoush
Mehrdad Panjnoush
PKPooneh Mohseni Kashani
Pooneh Mohseni Kashani
This study aimed to assess the effect of voxel size and object location in the field of view (FOV) on diagnostic accuracy of cone beam computed tomography (CBCT) for detection of simulated bone defects. In this in vitro study, bone defects were drilled in four sections of a dry human mandible. Bone blocks were fixed on a platform parallel to the horizontal plane and CBCT images were acquired using 0.2mm and 0.3mm resolutions and five locations of FOV (anterior, posterior, left, right and center). Three reviewers viewed the images twice and the presence or absence of simulated bone defects was determined in positive and negative cases. Sensitivity in different locations of FOV ranged between 0.25–1.0 and 0.75–1.0 in low and high resolutions, respectively. These values were 0.625–1.0 and 0.69–1.0, respectively for specificity. Intra-observer agreements were in the range of 0.84–1.0 and 0.75–1.0 and inter-observer agreements were in the range of 0.3–0.61 and 0.46–0.69 in high and low resolutions, respectively. The highest sensitivity was seen at the center of the FOV and with an increase in resolution from 0.3mm to 0.2mm, the sensitivity increased specially in the posterior region of the FOV while image resolutions and FOV locations did not affect specificity. The highest sensitivity values were obtained at the center of the FOV and lowest values were seen in images acquired in the posterior region in low resolution. Diagnostic accuracy improved with increased resolution.

17 February 2026 in Clinical and Experimental Dental Research
Verified
Journal Article
Open access
ZMZahra Madani
Zahra Madani
HFHoorieh Bashizadeh Fakhar
Hoorieh Bashizadeh Fakhar
Objectives: Modern dental implants have high long‐term survival, but peri‐implant marginal bone loss remains a multifactorial cause of implant failure and often is radiographically occult. Cone‐beam computed tomography (CBCT) provides superior 3D assessment but produces large datasets requiring expert interpretation. Deep‐learning object‐detection models like YOLOv8 may automate detection and grading. This study aimed to evaluate a YOLOv8‐based model for automated detection and grading of peri‐implant marginal bone loss on 2D images derived from CBCT. Materials and Methods: This retrospective study used 699 2D CBCT sections. Marginal bone loss was graded into four classes (≤ 20%, 21%–40%, 41%–60%, > 61% of implant length). A YOLOv8 detector was trained on 600 × 600‐pixel images (bounding box width 20 px) with two classes (implant, bone loss), split 80/10/10 (train/test/val), 200 epochs, batch size 8 and tuned hyperparameters. Performance was assessed by accuracy, precision, recall, and F1‐score. Results: The YOLOv8 model achieved strong diagnostic performance on the test set, with overall accuracy, precision, recall, and F1‐score of 0.90. It performed best for healthy sites (precision 0.92, recall 0.99, F1 0.95) and maintained high performance for mild lesions (F1 0.90), while moderate and severe cases showed reduced metrics (F1 0.62 and 0.70, respectively). A three‐class scheme had 0.88 accuracy and excellent reliability (Kappa = 0.954). Detection metric included mAP@0.5 (mean precision at intersection over union threshold of 0.5) of 0.889, a recall of 0.98 at low threshold, and implant‐length detection accuracy of 1.00. Training stabilized after about 15 epochs. Conclusions: The YOLOv8‐based deep learning model can reliably detect and grade peri‐implant marginal bone loss on CBCT images. Future research should expand datasets, incorporate multimodal information, and validate performance across diverse clinical settings.