Sarah K. Patch

Sarah K. Patch

Auto-generated profile, based on publicly available information

Sarah K. Patch

Department of Physics, UW-Milwaukee and Acoustic Range Estimates

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 December 2015 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
SPSarah K. Patch
Sarah K. Patch
DHDavid Hull
David Hull
WSWilliam A. See
William A. See
GHGeorge W. Hanson
George W. Hanson
Thermoacoustics has the potential to provide quantitative images of intrinsic tissue properties, most notably electrical conductivity in Siemens/meter, much as shear wave elastography provides tissue stiffness in kilopascal. Although thermoacoustic imaging with optical excitation has been commercialized for small animals, it has not yet made the transition to clinic for whole organ imaging in humans. The purpose of this work was to develop and validate specifications for a clinical ultrasound array for quantitative whole organ thermoacoustic imaging. Imaging a large organ requires exciting thermoacoustic pulses throughout the volume and broadband detection of those pulses because tomographic image reconstruction preserves frequency content. Applying the half-wavelength limit to a $200 \text{-}\upmu \text{m}$ inclusion inside a 7.5-cm diameter organ requires measurement sensitivity to frequencies ranging from 4 MHz to 10 kHz, respectively. A dual-transducer system utilizing a P4-1 array connected to a Verasonics V1 system as well as a focused single-element transducer sensitive to lower frequencies was developed. Very high-frequency (VHF) irradiation generated thermoacoustic pulses throughout a $6 \times 6 \times 5\ \text{cm}^{3}$ volume. In the VHF regime, electrical conductivity drives thermoacoustic signal production. Simultaneous acquisition of thermoacoustic pulses by both transducers enabled comparison of transducer performance. Data from the clinical array generated a stack of 96 images with a separation of 0.3 mm, whereas the single-element transducer imaged only in a single plane. In-plane resolution and quantitative accuracy were quantified at isocenter. The array provided volumetric imaging capability with superior resolution whereas the single-element transducer provided superior quantitative accuracy in axial images. Combining axial images from both transducers preserved resolution of the P4-1 array and improved image contrast. Neither transducer was sensitive to frequencies below 50 kHz, resulting in a dc offset and low-frequency shading over fields of view exceeding 15 mm. Fresh human prostates were imaged ex vivo and volumetric reconstructions reveal structures rarely seen in diagnostic images. In conclusion, quantitative whole-organ thermoacoustic tomography will be feasible by sparsely interspersing transducer elements sensitive to the low end of the ultrasonic range.

6 July 2016 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
SPS K Patch
S K Patch
MCM Kireeff Covo
M Kireeff Covo
AJA Jackson
A Jackson
YQY M Qadadha
Y M Qadadha
KCK S Campbell
K S Campbell
LPL Phair
L Phair
The potential of particle therapy due to focused dose deposition in the Bragg peak has not yet been fully realized due to inaccuracies in range verification. The purpose of this work was to correlate the Bragg peak location with target structure, by overlaying the location of the Bragg peak onto a standard ultrasound image. Pulsed delivery of 50 MeV protons was accomplished by a fast chopper installed between the ion source and the cyclotron inflector. The chopper limited the train of bunches so that 2 Gy were delivered in 2   μ s . The ion pulse generated thermoacoustic pulses that were detected by a cardiac ultrasound array, which also produced a grayscale ultrasound image. A filtered backprojection algorithm focused the received signal to the Bragg peak location with perfect co-registration to the ultrasound images. Data was collected in a room temperature water bath and gelatin phantom with a cavity designed to mimic the intestine, in which gas pockets can displace the Bragg peak. Phantom experiments performed with the cavity both empty and filled with olive oil confirmed that displacement of the Bragg peak due to anatomical change could be detected. Thermoacoustic range measurements in the waterbath agreed with Monte Carlo simulation within 1.2 mm. In the phantom, thermoacoustic range estimates and first-order range estimates from CT images agreed to within 1.5 mm.

21 December 2017 in Medical Physics
Verified
Journal Article
Open access
PDF file
SPSarah K. Patch
Sarah K. Patch
DHDaniel E. M. Hoff
Daniel E. M. Hoff
TWTyler B. Webb
Tyler B. Webb
LSLee G. Sobotka
Lee G. Sobotka
TZTianyu Zhao
Tianyu Zhao
Purpose: Range errors constrain treatment planning by limiting choice of ion beam angles and requiring large margins. Ionoacoustic range verification requires recovering the location of an acoustic source from low frequency signals. A priori information is applied to stably overcome resolution limits of inverse acoustic source imaging in this simulation study. In particular, the accuracy and robustness of ionoacoustic range verification for lateral and oblique delivery of high‐energy protons to the prostate is examined.Methods: Dose maps were computed using GEANT4 Monte Carlo simulations via the TOPAS user interface. Thermoacoustic pulses were propagated using k‐Wave software, with initial pressures corresponding to instantaneous dose deposition and piecewise constant maps of tissue properties derived from the planning CT. A database of dose maps with corresponding thermoacoustic emissions and Bragg peak locations, referred to as “control points,” were precomputed. Corresponding thermoacoustic emissions were also precomputed. Pulses were recorded at four coplanar locations corresponding to the outer surface of a virtual transrectal array. To model experimental beam delivery, k‐Wave results were convolved in time with a Gaussian envelope to account for noninstantaneous proton delivery by a synchrocyclotron. Thermoacoustic pulses were bandlimited below 150 kHz, and amplitudes were directly proportional to charge delivered. To test robustness of our method, white noise was added. Range was estimated in a two‐step process. The first step obtained a preliminary range estimate by one‐way beamforming. The second step was taken using data corresponding to the “control point” nearest to the preliminary range estimate. For each receiver, the time of flight difference, ∆t, between the measured and control thermoacoustic signals were accurately estimated by applying the Fourier shift theorem. Receiver‐Bragg peak distance was then estimated by adding vs∆t to the known distance of the control point, where vs is soundspeed. A linear system of equations based upon all receiver locations and distances was solved to recover the Bragg peak location. All simulations were performed relative to the planning CT. Because ultrasound (US) images were not available, results were overlaid onto the planning CT.Results: Beamformed estimates from noise‐free data tracked all beam locations within 1 cm. Final estimates for oblique and lateral beams were accurate to within 1.0 and 1.6 mm respectively. Average errors of final range estimates for oblique beams from data with SNR = 0 dB were no greater than 2.0 mm.Conclusions: Ionoacoustic range verification may improve current practice. Ionoacoustic range estimates can be inherently co‐registered to ultrasound images of underlying anatomy. To ensure estimates are robust in clinical practice, dose maps based upon the planning CT should be overlaid onto ultrasound volumes acquired at time of treatment and acoustic simulations re‐computed to provide a database of control points and corresponding thermoacoustic emissions. Computation times for beamformed estimates are already fast enough for online range verification, but are not accurate enough for a measurement aperture limited to the surface of a transrectal ultrasound probe. Accelerated acoustic simulations will be required to enable online two‐stage correction, but offline calculation is already suitable for adaptive planning.

25 October 2018 in Medical Physics
Verified
Journal Article
Open access
PDF file
SPSarah K. Patch
Sarah K. Patch
DSDaniel Santiago‐Gonzalez
Daniel Santiago‐Gonzalez
BMBrahim Mustapha
Brahim Mustapha
Purpose: To demonstrate robustness of thermooacoustic range verification to acoustic heterogeneity and discrepancies between assumed and true propagation speed, i.e., soundspeed errors.Methods: A beam sweeper was used to deliver 250 ns pulses that deposited 0.26 Gy of 16 MeV protons and 2.3 Gy of 60 MeV helium ions into water and oil targets, respectively. Thermoacoustic signals were detected by a 96‐channel ultrasound array with a 1–4 MHz sensitivity band (−6 dB), bandpass filtered and backprojected to create thermoacoustic images in the plane of the ultrasound array. The same soundspeed and transducer array were used to estimate range and generate the ultrasound images onto which Bragg peak locations were overlaid. An air‐gap phantom that displaced the Bragg peak by 6.5 mm demonstrated accuracy. Robustness to soundspeed errors was demonstrated in a waterbath as the assumed propagation speed scanner setting was altered by . Tissue‐mimicking gelatin and a bone sample were introduced to demonstrate robustness to acoustic heterogeneity relative to ultrasound images of the underlying morphology.Results: Single ion pulse measurements sufficed during the helium run, but signal averaging was required for protons. Range and entry point into the target were estimated from data collected by transducers placed at least 6 cm distal to the Bragg peak. When ultrasound images depicted the air–target interface where the beam enters, estimates of the entry point agreed with ultrasound images and range estimates agreed with Monte Carlo simulations to within 300 μm, even when thermoacoustic emissions traveled through a strongly scattering bone sample. Estimated Bragg peak locations were translated 6.5 mm by the air‐gap phantom and correctly identified scenarios when the beam stopped inside the bone.Conclusions: Soundspeed errors dilate and acoustic heterogeneities deform ultrasound images. When thermoacoustic receivers are co‐located with the ultrasound imaging array, the same transformations shift thermoacoustic range estimates. Therefore, thermoacoustic range verification is robust relative to ultrasound images of underlying anatomy. When the treatment target is visible in ultrasound, e.g., prostate, online thermoacoustic range estimates could verify that the treatment spot is inside the target.

3 January 2013 in Ultrasonic Imaging
Verified
Journal Article
Closed access
MRM. A. Roggenbuck
M. A. Roggenbuck
RWR. D. Walker
R. D. Walker
JCJ. W. Catenacci
J. W. Catenacci
SPS. K. Patch
S. K. Patch
The thermoacoustic (TA) contrast mechanism relies on rapid tissue heating and subsequent thermal expansion. TA computerized tomography (TCT) is therefore inverse source imaging. The TA contrast mechanism provides information complementary to that revealed by current diagnostic imaging techniques, but has been limited to just a few centimeters depth penetration. In this article, whole organ TCT is demonstrated on a large swine kidney. TA sinograms show that TA signal generated by high-power, very high frequency (VHF) electromagnetic pulses is detectable after travel through 6 cm of soft tissue. Reconstructed images provide resolution sufficient to track progression of calyces throughout the kidney. Because VHF electromagnetic energy can easily penetrate the abdomen of large adults, our results indicate that whole organ TA imaging is feasible in vivo, provided an ultrasound array can be placed near the region of interest. Pulses of 22 to 25 kW with carrier frequency 108 MHz and 900 ns pulse width were applied at a 100-Hz pulse repetition frequency to generate a 13-kV/m electric field and TA signal. Only 2 to 5 mJ was absorbed in the kidney per pulse, causing temperature and pressure jumps of only 5e-6°C and 4 Pa averaged throughout the 141-g specimen. TA pulses were detected by focused, single-element transducers (V306, Panametrics), amplified by 54 dB and averaged 64 times to reduce electronic noise. Data were measured over a cylindrical measurement aperture of radius 5 cm and length 6 cm, by rotating the specimen 1.8 degrees between tomographic views and translating 2 mm between slices. Reconstruction via filtered backprojection yields in-plane resolution better than 5 mm, but suffers significant blurring between planes. Both in-plane resolution and slice sensitivity profile could be improved by applying shorter irradiation pulsewidths and using less directional transducers. Both hardware changes would be recommended for a clinical prototype.

18 December 2019 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
VHVijay Harid
Vijay Harid
MGMark Golkowski
Mark Golkowski
SGStephen D. Gedney
Stephen D. Gedney
MCMorris Cohen
Morris Cohen
SPSarah K. Patch
Sarah K. Patch
HKHoyoung Kim
Hoyoung Kim
The ability of extremely and very low frequency (ELF/VLF, 0–30 kHz) radio waves to penetrate conductive media is well established. Magnetic field penetration into a thin but highly conductive box using an ELF/VLF loop antenna transmitter is investigated. The work is relevant for electromagnetic shielding of ELF/VLF sensors, defect detection, inductive power transfer, and through container imaging. Analytical solutions are reviewed for related shielding problems, however, determining the penetration through a realistic shield geometry and finite sized near-field source requires a numerical approach. Surface integral equation (SIE) methods are well suited for shield modeling due to the low surface area to volume ratio of the shield. Method of moment techniques have been successfully applied to solving SIEs in the past, however, enforcing algorithm stability at low frequencies is known to require considerable effort. To alleviate the low-frequency concerns, a high-order locally corrected Nyström (LCN) scheme is utilized to solve an SIE based on an augmented Müller formulation of Maxwell’s equations. To validate the LCN simulations, an experiment is conducted using a loop antenna inside a 1.2 m aluminum cube of 2.7 mm thickness with an external ELF/VLF loop transmitter. Experimental results are shown to match within 3 dB of the LCN code predictions.