Elizabeth Doig-Camino

Elizabeth Doig-Camino

Auto-generated profile, based on publicly available information

Elizabeth Doig-Camino

Mathematic Section, Department of Sciences, Pontifical Catholic University of Peru San Miguel, Lima, Perú

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2019 in Journal of Chemistry
Verified
Journal Article
Open access
PDF file
APAna Lucía Paredes-Doig
Ana Lucía Paredes-Doig
HCH. Cárcamo
H. Cárcamo
MCMario Hurtado Cotillo
Mario Hurtado Cotillo
RSR. Sun-Kou
R. Sun-Kou
EDE. Doig-Camino
E. Doig-Camino
AGAdolfo La Rosa-Toro Gómez
Adolfo La Rosa-Toro Gómez
The present work develops a MOS-based e-nose with sensors modified with zeolite Y. For this purpose, the following SnO2 doped with Pd and/or Pt have been prepared: M1 ((0.25 Pd/0.75 Pt)/SnO2), M2 ((0.50 Pd/0.50 Pt)/SnO2), M3 ((0.75 Pd/0.25 Pt)/SnO2), Pd/SnO2, and Pt/SnO2, at the total concentrations of the noble metals of 0.1% and 0.2% for use in gas sensors and be part of the electronic nose. Then, the sensors were assembled with the oxides using the screen printing method. Different electronic noses of four sensors were prepared by combining tin oxides doped with palladium and/or platinum and zeolite Y. The physicochemical characterization of oxides using FRX, FTIR, sorption of N2, and RAMAN has been performed. Measurements for the detection of wine volatile compounds such as ethanol, methanol, 1-phenyl ethanol, propionic acid, and acetic acid were carried out with these sensors located in a gas chamber and using a program that includes the Labview software, which serves to automate the sensing process. It was found that the sensors modified with zeolite were the ones that in general had higher detections of volatile compounds and PCAs showed positive correlations only for ethanol and the mixture of ethanol at 12% and methanol at 3%. This is related to better detection of these sensors.

14 January 2022 in infoANALÍTICA
Verified
Journal Article
Open access
PDF file
APAna Lucía Paredes-Doig
Ana Lucía Paredes-Doig
MSMaría Sun-Kou
María Sun-Kou
EDElizabeth Doig-Camino
Elizabeth Doig-Camino
GPGino Picasso
Gino Picasso
AGAdolfo La Rosa-Toro Gómez
Adolfo La Rosa-Toro Gómez
This work presents the results of the sensing analysis of Peruvian wines of known (Commercial wines) and handmade brands, using electronic noses (E-noses) which consist of an array of sensors based on tin oxide doped with Pd or Pt, and some with zeolite coating. The combinations of the sensors were performed seeking to obtain the best discrimination of the wines with the multivariate methods, with a high level of confidence and a good distribution of the results. The Principal Component Analysis (PCA), cluster and factorial results showed that the electronic noses allowed to efficiently identify wines of known brand from those of handmade brand, revealing the way in which the wines have been produced. On the other hand, the multivariate methods applied to the electronic noses made up of SnO2 sensors doped with palladium showed a clear differentiation of Borgoña-type wines from wines of handmade brand and evidenced the formation of agglomerations between red and Rosé wines. The application of PCA, cluster and factorial obtained in this study allowed to obtain good results in the differentiation of wines, even with electronic noses formed with a low number of sensors.

5 September 2022 in Journal of Engineering Research
Verified
Journal Article
Open access
APAna Lucía Paredes-Doig
Ana Lucía Paredes-Doig
HCHenry Cárcamo
Henry Cárcamo
EDElizabeth Doig-Camino
Elizabeth Doig-Camino
GPGino Picasso
Gino Picasso
AGAdolfo La Rosa-Toro Gómez
Adolfo La Rosa-Toro Gómez
MSMaria R. Sun-Kou
Maria R. Sun-Kou
En este trabajo, algunos vinos tintos peruanos se analizaron utilizando cromatografía de gases acoplados a espectrometría de masas (GC-MS) y se determinó que el etanol era el principal componente volátil presente en el aroma (12% en volumen). seguido de metanol (2-3% en volumen). Algunos sensores MOS basados en SnO2 dopados con Pd y Pt se prepararon mediante impregnación húmeda con cargas metálicas de 0,1 a 0,5% y se probaron con los mismos vinos peruanos. La estabilidad y la reproducibilidad de la señal de detección se analizaron a diferentes temperaturas de trabajo (200, 220, 240, 260 y 280 ° C). La mejor temperatura de trabajo en la que se obtuvo la mayor intensidad de la señal de respuesta de los sensores a 260 ⁰c. En la mayoría de los casos estudiados, la señal de detección de los sensores fue en general repetitiva y estable, manteniendo su amplitud y forma durante largos períodos de análisis. Sin embargo, a la temperatura de 280 ° C, la señal pierde intensidad y en contacto con metanol, la señal se distorsiona.

17 May 2022
Verified
Book Chapter
Open access
MKMaría del Rosario Sun Kou
María del Rosario Sun Kou
HCHenry Cárcamo Cabrera
Henry Cárcamo Cabrera
APAna Lucía Paredes-Doig
Ana Lucía Paredes-Doig
EDElizabeth Doig-Camino
Elizabeth Doig-Camino
GPGino Picasso
Gino Picasso
YRYarit Samantha Haro Ramírez
Yarit Samantha Haro Ramírez