Abdul Barik

Abdul Barik

Auto-generated profile, based on publicly available information

Abdul Barik

Centre for Smart Power and Energy Research (CSPER), School of Engineering Deakin University Geelong Australia

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2018 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
ABAbdul Barik
Abdul Barik
AGAmeen Gargoom
Ameen Gargoom
Md Apel MahmudMd Apel Mahmud
Md Apel Mahmud
Enamul HaqueEnamul Haque
Enamul Haque
HAHassan Al-Khalidi
Hassan Al-Khalidi
AOAmanullah Maung Than Oo
Amanullah Maung Than Oo
This paper presents a decentralized fault detection technique for power distribution systems with resonant grounding. The aim of this paper is to detect single phase to ground faults and identify the faulty feeder within three cycles of the fault occurrence. In the proposed technique, faults are first detected based on the neutral voltage displacement. The pre-fault and post-fault voltages (phase to ground) are then used to identify the faulty phase. Finally, the faulty feeder (as well as the faulty area of a long feeder) is identified from the relationship between the initial transient of the zero-sequence current and the faulty phase voltage just after the occurrence of faults. A signal processing tool called mathematical morphology is utilized to identify the faulty feeder. To identify the faulty feeder, it is also required to know the fault occurrence time that is estimated using the slope of the neutral voltage. The main feature of the proposed scheme is that this technique only uses voltage and current signals from the corresponding voltage transformers and current transformers. Therefore, it does not require communication among protection devices in the same or different feeders to identify the faulty feeder. The proposed technique also has the ability to distinguish the nature of faults, i.e., whether the faults are permanent or temporary. The effectiveness of the proposed scheme is tested, on an IEEE test system as well as on a practical test system, using MATLAB/SimPowerSystems. Simulation results show that the proposed technique can quickly detect the single phase to ground faults in a resonant grounding power distribution system and identify the faulty feeder. It is also capable of distinguishing faults from other disturbances. Moreover, it works under different compensation levels as well as for different fault inception angles.

7 December 2020 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
ABAbdul Barik
Abdul Barik
AGAmeen Gargoom
Ameen Gargoom
Md Apel MahmudMd Apel Mahmud
Md Apel Mahmud
EHEnamul Haque
Enamul Haque
MCMartin Cavanagh
Martin Cavanagh
AOAman Maung Than Oo
Aman Maung Than Oo
This study presents an automatic network balancing technique to limit the capacitive unbalance in resonant grounded power distribution systems (RGPDSs). The aim of this capacitive balancing technique is to minimise the unbalance current through the line to ground (which is the current through the neutral of the system) in order to automatically limit the neutral voltage. The proposed technique is designed by combining the weighted‐sum technique and genetic algorithm (GA), where distributed switched capacitor banks (SCBs) are used for balancing RGPDSs. The proposed technique is employed to optimise available SCBs for limiting the network unbalance at the substation under a pre‐defined threshold considering all possible network configurations. The unbalances at different locations of the network are also minimised to limit the system unbalance within the threshold due to minor changes in network parameters. Since the lifetime of capacitor banks relies on the switching, the proposed technique is designed in such a way that the system balance is achieved with the minimum switching. The performance of the proposed technique is evaluated through simulation studies in MATLAB/SimpowerSystems environment. Simulation results show that the proposed technique works well and capable to maintain the capacitive balance of the system with changes in network configurations.