Walton Nosé

Walton Nosé

Auto-generated profile, based on publicly available information

Walton Nosé

Eye Clinic, Sao Paulo, Brazil

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2010 in Ophthalmology
Verified
Journal Article
Closed access
BFBruno M. Fontes
Bruno M. Fontes
RARenato Ambrósio
Renato Ambrósio
DJDaniela Jardim
Daniela Jardim
GVGuillermo C. Velarde
Guillermo C. Velarde
WNWalton Nosé
Walton Nosé

1 November 2006 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
KRKarolinne Maia Rocha
Karolinne Maia Rocha
ESEduardo S. Soriano
Eduardo S. Soriano
MCMaria Regina Chalita
Maria Regina Chalita
AYAna Carolina Yamada
Ana Carolina Yamada
KBKátia Bottós
Kátia Bottós
WNWalton Nosé
Walton Nosé

1 November 2007 in Ophthalmology
Verified
Journal Article
Closed access
KRKarolinne Maia Rocha
Karolinne Maia Rocha
ESEduardo S. Soriano
Eduardo S. Soriano
WCWallace Chamon
Wallace Chamon
MCMaria Regina Chalita
Maria Regina Chalita
WNWalton Nosé
Walton Nosé

1 March 2011 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
BFBruno M. Fontes
Bruno M. Fontes
RARenato Ambrósio
Renato Ambrósio
GVGuillermo Coca Velarde
Guillermo Coca Velarde
WNWalton Nosé
Walton Nosé
Purpose: To compare corneal hysteresis (CH) and corneal resistance factor (CRF) in eyes with keratoconus with a central corneal thickness (CCT) ≥520 μm with CH and CRF in matched controls, and to estimate the sensitivity and specificity of these parameters for discriminating between the two groups. Methods: This prospective, comparative case series comprised 19 eyes of 19 patients with keratoconus with CCT ≥520 μm and 19 eyes of 19 healthy sex-, age-, and CCT-matched patients who underwent a complete clinical eye examination, corneal topography, tomography, and biomechanical evaluation. The receiver operating characteristic (ROC) curve was used to identify cutoff points that maximized the sensitivity and specificity for discriminating between groups. Results: Central corneal thickness was 543.1±13.9 μm (range: 520 to 568 μm) in the keratoconus group and 545±12.5 μm (range: 527 to 575 μm) in the control group ( P =.6017). Corneal hysteresis was 9.22±1.44 mmHg (range: 6.2 to 11.35 mmHg) in the keratoconus group and 10.58±1.91 mmHg (range: 7.34 to 13.53 mmHg) in the control group ( P =.0075). Corneal resistance factor was 8.62±1.52 mmHg (range: 5.60 to 11.20 mmHg) in the keratoconus group and 10.30±1.92 mmHg (range: 6.95 to 14.12 mmHg) in the control group ( P =.0049). The ROC curve analyses showed a poor overall predictive accuracy of CH (cutoff, 9.90 mmHg; sensitivity, 78.9%; specificity, 63.2%; test accuracy, 71.05%) and CRF (cutoff, 8.90 mmHg; sensitivity, 68.4%; specificity, 78.9%; test accuracy, 73.65%) for detecting keratoconus in the eyes studied. Conclusions: Corneal hysteresis and CRF were statistically lower in the keratoconus group compared with the control group. Given the large overlap, both CH and CRF had low sensitivity and specificity for discriminating between groups.

1 April 1999 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
AFAdriana S. Forseto
Adriana S. Forseto
CFClaudia M. Francesconi
Claudia M. Francesconi
RNRegina A.M. Nosé
Regina A.M. Nosé
WNWalton Nosé
Walton Nosé
To assess the safety and effectiveness of excimer laser in situ keratomileusis (LASIK) to correct refractive myopia, astigmatism, or both after keratoplasty. Eye Clinic Day Hospital, São Paulo, Brazil. Twenty-two eyes that had previously had corneal transplantation were studied. Laser in situ keratomileusis was performed using the Chiron automated microkeratome and the VISX Twenty-Twenty B excimer laser. Mean follow-up after LASIK was 10.09 months +/- 3.87 (SD). The spherical equivalent refraction dropped from -4.55 +/- 3.66 D before LASIK to -0.67 +/- 1.24 D after surgery. At the last examination, 72.7% of patients had a refractive error within +/- 1.00 D of emmetropia and 54.5% had uncorrected visual acuity of 20/40 or better. Vector analysis of astigmatic correction showed an index of success of 54.0%. Best spectacle-corrected visual acuity was unchanged in 8 cases, improved in 9, and decreased in 5. Significant endothelial cell loss, keratoplasty wound dehiscence, and other serious complications did not develop in any eye. The correction of refractive error with LASIK in postkeratoplasty patients proved to be safe, effective, and predictable. Further studies with longer follow-up are needed to determine the method's clinical value.

1 August 2007 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
KRKarolinne Maia Rocha
Karolinne Maia Rocha
WNWalton Nosé
Walton Nosé
KBKátia Bottós
Kátia Bottós
JBJuliana Bottós
Juliana Bottós
LMLisângela Morimoto
Lisângela Morimoto
ESEduardo Soriano
Eduardo Soriano
To analyze higher-order aberrations induced by different types of lenticular opacities. Federal University of São Paulo, São Paulo, Brazil. One hundred thirty-eyes of 65 patients with bilateral cataract, classified according to the Lens Opacities Classification System III (LOCS III), had complete ophthalmic examinations, corneal topography (EyeSys Technologies), and wavefront analysis (LADARWave, Alcon Laboratories). Patients with cataracts that could not be measured by a Hartmann-Shack sensor or those with coexisting ocular disease were excluded. Higher-order aberrations were compared between the nuclear, cortical, and posterior subcapsular groups for statistical significance. One hundred five eyes of 65 patients were assessed. Twenty-eight eyes (23.33%) had predominantly nuclear opacification (NO1-NO6 and C1-2), and 13 (10.83%) had mainly cortical opacification (C1-4). Sixty-four eyes (65.83%) had a mixed pattern of LOCS III classification, which hindered the establishment of a correlation between the aberrometry and cataract type. Eighteen eyes that presented with dense posterior subcapsular cataract (P4-5) and 7 eyes with cortical C5 LOCS III classification were excluded. In eyes with nuclear opacification, the mean spherical aberration with a 6.0 mm pupil was 0.45 microm +/- 0.17 (SD) and the mean coma was 0.29 +/- 0.13 microm. In eyes with predominantly cortical cataract, the mean spherical aberration was 0.12 +/- 0.10 microm and the mean coma was 0.49 +/- 0.23 microm. The cortical cataract group had statistically significantly higher coma than the other groups (P<.001). The nuclear cataract group had statistically significantly higher spherical aberrations than the other groups (P<.001). Different types of early lenticular opacities induced different wavefront aberration profiles. Coma predominated in the cortical cataract group, and spherical aberration predominated in the nuclear cataract group.