A. R. Dar

A. R. Dar

Auto-generated profile, based on publicly available information

A. R. Dar

Department of Civil Engineering, National Institute of Technology. Srinagar, J&K, India

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2018 in Advances in Structural Engineering
Verified
Journal Article
Closed access
Mohammad Adil DarMohammad Adil Dar
Mohammad Adil Dar
NSN Subramanian
N Subramanian
ADA R Dar
A R Dar
MAM. Anbarasu
M. Anbarasu
JLJames Bp Lim
James Bp Lim
MAMir Atif
Mir Atif
To address the various instability problems in cold-formed steel members, many researchers have mainly focused on developing innovative sectional profiles wherein geometry of the section plays a vital role in enhancing the inherent resistance of such sections against premature buckling. However, the process of forming such innovative shapes is not only complex and time-consuming but sometimes such sections fail to mobilize their complete reserve strength. Hence, a stiffening arrangement of weaker zones for mobilizing the untapped reserve strength is suggested. The contribution of this simple, effective and partly stiffening arrangements, aimed at eliminating/delaying the premature local buckling, is studied both experimentally and numerically and also compared with existing codes. Experimental study was carried out on different simply supported cold-formed steel beams with judiciously proposed stiffening arrangements under four-point loading. An equivalent hot-rolled steel beam was also tested to compare the efficiency of the cold-formed steel beams. The cold-formed steel beams investigated had different width-to-thickness ratio, different geometries and different stiffening arrangements. The test strengths, failure modes, deformed shapes, load versus mid-span displacements and geometric imperfections were measured and reported. The test strengths of the beam models are also compared with the design strength predicted by North American Standards and Eurocode for cold-formed steel structures. To validate the test results further, a numerical study was carried out on such stiffened cold-formed steel beams using finite element software ABAQUS. All these results show that the proposed strengthening system is efficient and economical and allow cold-formed steel beams to reach greater load carrying capacity.

25 December 2015 in Steel and Composite Structures
Verified
Journal Article
Closed access
Mohammad Adil DarMohammad Adil Dar
Mohammad Adil Dar
MYM. Yusuf
M. Yusuf
ADA.R. Dar
A.R. Dar
JRJ. Raju
J. Raju
Experimental study on innovative sections for cold formed steel beams buckling modes;cold formed steel;failure modes;innovative sectional profiles;structural behavior;structural efficiency;ultimate load carrying capacity; Cold Formed Steel members are widely used in today's construction industry. However the structural behavior of light gauge high strength cold formed steel sections characterized by various buckling modes are not yet fully understood. Because of their simple forming and easy connections, the commonly used cold formed sections for beams are C and Z. However both these sections suffer from certain buckling modes. To achieve much improved structural performance of cold formed sections for beams both in terms of strength and stiffness, it is important to either delay or completely eliminate their various modes of buckling. This paper presents various innovative sectional profiles and stiffening arrangements for cold formed steel beams which would successfully contribute in delaying or eliminating various modes of premature buckling, thus considerably improving the load carrying capacity as well as stiffness characteristics of such innovative cold formed sections compared to conventional cold formed steel sections commonly used for beams.

1 October 2020 in Engineering Structures
Verified
Journal Article
Closed access
MDM. Adil Dar
M. Adil Dar
NSN. Subramanian
N. Subramanian
ADA.R. Dar
A.R. Dar
AGAhmad Fayeq Ghowsi
Ahmad Fayeq Ghowsi
FSFaizan Sidiqui
Faizan Sidiqui
MMM. Shoaib Mir
M. Shoaib Mir

13 October 2021 in Advances in Structural Engineering
Verified
Journal Article
Closed access
PDF file
ADA.R. Dar
A.R. Dar
SVS. Vijayanand
S. Vijayanand
MAM. Anbarasu
M. Anbarasu
Mohammad Adil DarMohammad Adil Dar
Mohammad Adil Dar
Some of the past studies on cold-formed steel (CFS) battened built-up columns have resulted in the development of new design rules for predicting their axial strengths. However, the main drawbacks of such studies are that they are purely numerical and the numerical models developed for such parametric studies were validated using the test results on similar built-up column configurations, but not the exact ones. Therefore, experimental studies on CFS battened columns comprising of lipped channels are needed for verifying the accuracy of the proposed design rules for CFS battened columns. This paper reports an experimental study performed on CFS built-up battened columns under axial compression. Adequately spaced identical lipped channels in the back-to-back arrangement were used as chords and were connected by batten plates laterally with self-driving screws to form the built-up members. The dimensions of chords were fixed as per the geometric limits given out in the North American Specifications (NAS) for the design of CFS structural members. The sectional compactness of the chords and the overall slenderness of the built-up columns were varied by altering the thickness of the channels and height of the built-up columns, respectively. A total of 20 built-up sections were tested under uniform compression to investigate the behavioural changes in the built-up columns due to these variations. The behaviour assessment was made in terms of peak strengths, load–displacement response and failure modes of the test specimens. The current design standards on CFS structures were used to determine the design strengths and were compared against the test strengths for assessing their adequacy. Furthermore, as discussed in the beginning, the test strengths were used to verify the accuracy of the different relevant proposed design rules in the literature.

1 January 2020 in Materials Today: Proceedings
Verified
Journal Article
Closed access
ADA.R. Dar
A.R. Dar

25 November 2015 in STRUCTURAL ENGINEERING AND MECHANICS
Verified
Journal Article
Closed access
Mohammad Adil DarMohammad Adil Dar
Mohammad Adil Dar
NSN. Subramanian
N. Subramanian
ADA.R. Dar
A.R. Dar
JRJ. Raju
J. Raju
Experimental investigations on the structural behaviour of a distressed bridge truss girder bridge;pipe rack;severe distress;bearing plate;remedial measures; Distressed structures require necessary remedial measures in order to restore their original structural properties like strength and stiffness. Validating the effectiveness of the proposed qualitative remedial measure experimentally is of utmost importance as there is no well-established analytical method to verify the effectiveness of the same quantitatively. Prototype testing which would have been the best option for this purpose would not only prove costly but also be associated with numerous practical difficulties; hence model testing is resorted as the only option for the purpose. This paper presents one such typical experimental study on the structural behavior of a distressed bridge, mainly observed in the form of prominent tilt in the bearing plate in transverse and longitudinal direction on downstream side. The main focus of the proposed experimental investigation is to assess the structural behavior particularly the load carrying capacity. The extent of deformation of some models with specific structural arrangements and some models with specific need based remedial measures were also studied. This study also assessed the contribution of each remedial measure towards restoration individually and collectively.