Jia Xu

Jia Xu

Auto-generated profile, based on publicly available information

Jia Xu

Department of Ultrasound Sichuan Integrative Medicine Hospital Chengdu China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2020 in Journal of Ultrasound in Medicine
Verified
Journal Article
Closed access
PDF file
JXJia Xu
Jia Xu
LQLang Qiao
Lang Qiao
KXKailing Xiong
Kailing Xiong
SCShutao Cheng
Shutao Cheng
HLHong Luo
Hong Luo
MPMei Pan
Mei Pan

29 October 2025 in Journal of Clinical Ultrasound
Verified
Journal Article
Open access
QHQiuyun Huang
Qiuyun Huang
YLYunhao Luo
Yunhao Luo
JXJia Xu
Jia Xu
DWDanlin Wen
Danlin Wen
FLFangqin Liu
Fangqin Liu
LQLang Qiao
Lang Qiao
Objective: To investigate the diagnostic value of contrast‐enhanced ultrasound (CEUS) in differentiating benign and malignant endometrial diseases by analyzing the early arterial vascular architecture on CEUS images. Methods: A prospective study was conducted at the Sichuan Integrative Medicine Hospital to enroll 70 suspected endometrial lesion patients with a mean age of 42.5 ± 8.2 years (range 27–69 years). The patients underwent conventional ultrasound and CEUS examinations, and pathological examinations were obtained through surgery or curettage. They were divided into the benign group and malignant group according to their pathological types. The CEUS image features were analyzed, and the sensitivity, specificity, positive predictive value, and other parameters were compared between the two groups by carefully observing the early enhancement images and comparing the differences in the vascular architecture, including the shape of the vessels, the number of vessels, and the vessel diameter. Results: There were significant differences in vascular shape, number, and diameter between the two groups. The difference in vascular morphology was highly statistically significant ( p < 0.001). The “vascular supply” was used for the diagnosis of malignant diseases of the endometrium with a high sensitivity of 95.8%, specificity of 77.5%, positive predictive value of 71.8%, and accuracy of 84.4%. When the maximum inner diameter exceeded 1.5 mm, the sensitivity and specificity for the diagnosis of malignant lesions were 95.8% and 82.5%, respectively, with a positive predictive value of 76.6% and an accuracy of 87.5%. When the average inner diameter exceeded 1.22 mm, the sensitivity for the diagnosis of malignant endometrial lesions was 87.5%, the specificity was 80%, and the accuracy was 82.8%. Conclusions: The utilization of CEUS vascular architecture holds significant clinical value in the diagnosis of both benign and malignant endometrial diseases, thereby warranting further comprehensive investigation.

28 June 2023 in Authorea
Verified
Preprint
Open access
PDF file
JXJia Xu
Jia Xu
LQLang Qiao
Lang Qiao
LNLi Na
Li Na
DWDanlin Wen
Danlin Wen
DQDiao Qian
Diao Qian
HLHong Luo
Hong Luo
Objective This article aims to analyze correlations between microvascular density (MVD) of nude mice as well as VEGF and contrast-enhanced ultrasound (CEUS) parameters. Method Construct a model with 60 ovarian cancer of nude mice. Via ultrasound contrast agent injected intravenously.the enhancement features of tumors were observed in real time and the time-intensity curve (TIC) of CEUS was also obtained. By conducting quantitative analysis of Gamma-fit, we were able to get the relative parameters. Utilizing CD34 and CD31 for counting, the indices of MVD and VEGF level of “hotspot” area inside the tumors were measured. Through the analysis of CEUS image characteristics of ovarian cancer model in contrast with IHC indices, we discussed about their correlations. We matched 10 nude mice granuloma models to find differences between IHC quotas and CEUS parameters. Result The differences in CEUS clearing patterns of nude mice with different growth periods (30 days / 40 days) were considered statistically significant. surface density and H-score of CD31, CD34 and VEGF were significantly different between the transplanted tumor group and the granuloma group in nude mice.Statistics in correlation between CEUS parameter indices and IHC showed that the area under the curve (AUC)and average optical density of CD31 are positively correlated,the arrival time (ATM) and average optical density of VEGF are positively correlated. Conclusion There are differences among the microvascular architectures of ovarian cancer given different growth cycles. CEUS has shown its value during the clearing phases. The microvascular architecture of ovarian cancer and granuloma is obviously different. However, there are overlaps between their CEUS performances, where there is no significant statistical difference. The area under the curve (AUC) and time to arrival (ATM) of the quantifiers were positively correlated with CD31 and VEGF, which is helpful for clinical applications in early diagnosis and prognosis of ovarian cancer patient