Paul Renz

Paul Renz

Auto-generated profile, based on publicly available information

Paul Renz

Division of Radiation Oncology, Allegheny General Hospital, Pittsburgh, PA, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Closed access
PRPaul Renz
Paul Renz
SHShaakir Hasan
Shaakir Hasan
SGSteven Gresswell
Steven Gresswell
RHRaymond T. Hajjar
Raymond T. Hajjar
MTMark Trombetta
Mark Trombetta
JFJames Fontanesi
James Fontanesi


14 January 2021 in Brachytherapy
Verified
Journal Article
Closed access
BDBasem A. Dahshan
Basem A. Dahshan
JWJoshua S. Weir
Joshua S. Weir
RBRobert P. Bice
Robert P. Bice
PRPaul Renz
Paul Renz
DCDaniel T. Cifarelli
Daniel T. Cifarelli
CCChristopher P. Cifarelli
Christopher P. Cifarelli

3 November 2023 in Cancers
Verified
Journal Article
Open access
PDF file
DLDanny Lee
Danny Lee
PRPaul Renz
Paul Renz
SOSeungjong Oh
Seungjong Oh
MHMin-Sig Hwang
Min-Sig Hwang
DPDaniel Pavord
Daniel Pavord
AKAlexander Kirichenko
Alexander Kirichenko
A 1.5T MRI combined with a linear accelerator (Unity®, Elekta; Stockholm, Sweden) is a device that shows promise in MRI-guided stereotactic body radiation treatment (SBRT). Previous studies utilized the manufacturer’s pre-set MRI sequences (i.e., T2 Weighted (T2W)), which limited the visualization of pancreatic and intra-abdominal tumors and organs at risk (OAR). Here, a T1 Weighted (T1W) sequence was utilized to improve the visualization of tumors and OAR for online adapted-to-position (ATP) and adapted-to-shape (ATS) during MRI-guided SBRT. Twenty-six patients, 19 with pancreatic and 7 with intra-abdominal cancers, underwent CT and MRI simulations for SBRT planning before being treated with multi-fractionated MRI-guided SBRT. The boundary of tumors and OAR was more clearly seen on T1W image sets, resulting in fast and accurate contouring during online ATP/ATS planning. Plan quality in 26 patients was dependent on OAR proximity to the target tumor and achieved 96 ± 5% and 92 ± 9% in gross tumor volume D90% and planning target volume D90%. We utilized T1W imaging (about 120 s) to shorten imaging time by 67% compared to T2W imaging (about 360 s) and improve tumor visualization, minimizing target/OAR delineation uncertainty and the treatment margin for sparing OAR. The average time-consumption of MRI-guided SBRT for the first 21 patients was 55 ± 15 min for ATP and 79 ± 20 min for ATS.

18 May 2024 in Clinical and Translational Radiation Oncology
Verified
Journal Article
Open access
GGGuus Grimbergen
Guus Grimbergen
HEHidde Eijkelenkamp
Hidde Eijkelenkamp
LSLouk M.W. Snoeren
Louk M.W. Snoeren
RBRana Bahij
Rana Bahij
UBUffe Bernchou
Uffe Bernchou
GMGert J. Meijer
Gert J. Meijer
Treatment planning for MR-guided stereotactic body radiotherapy (SBRT) for pancreatic tumors can be challenging, leading to a wide variation of protocols and practices. This study aimed to harmonize treatment planning by developing a consensus planning protocol for MR-guided pancreas SBRT on a 1.5 T MR-Linac. A consortium was founded of thirteen centers that treat pancreatic tumors on a 1.5 T MR-Linac. A phased planning exercise was conducted in which centers iteratively created treatment plans for two cases of pancreatic cancer. Each phase was followed by a meeting where the instructions for the next phase were determined. After three phases, a consensus protocol was reached. In the benchmarking phase (phase I), substantial variation between the SBRT protocols became apparent (for example, the gross tumor volume (GTV) D99% ranged between 36.8 – 53.7 Gy for case 1, 22.6 – 35.5 Gy for case 2). The next phase involved planning according to the same basic dosimetric objectives, constraints, and planning margins (phase II), which led to a large degree of harmonization (GTV D99% range: 47.9–53.6 Gy for case 1, 33.9–36.6 Gy for case 2). In phase III, the final consensus protocol was formulated in a treatment planning system template and again used for treatment planning. This not only resulted in further dosimetric harmonization (GTV D99% range: 48.2–50.9 Gy for case 1, 33.5–36.0 Gy for case 2) but also in less variation of estimated treatment delivery times. A global consensus protocol has been developed for treatment planning for MR-guided pancreatic SBRT on a 1.5 T MR-Linac. Aside from harmonizing the large variation in the current clinical practice, this protocol can provide a starting point for centers that are planning to treat pancreatic tumors on MR-Linac systems.

1 October 2019 in Advances in Radiation Oncology
Verified
Journal Article
Open access
AMApril Metzger
April Metzger
PRPaul Renz
Paul Renz
SHShaakir Hasan
Shaakir Hasan
SKStephen Karlovits
Stephen Karlovits
JSJason Sohn
Jason Sohn
SGSteven Gresswell
Steven Gresswell
Repeat computed tomography (CT) simulation is problematic because of additional expense of clinic resources, patient inconvenience, additional radiation exposure, and treatment delay. We investigated the factors and clinical impact of unplanned CT resimulations in our network. We used the billing records of 18,170 patients treated at 5 clinics. A total of 213 patients were resimulated before their first treatment. The disease site, location, use of 4-dimensional CT (4DCT), contrast, image fusion, and cause for resimulation were recorded. Odds ratios determined statistical significance. Our total rate of resimulation was 1.2%. Anal/colorectal (P < .001) and head and neck (P < .001) disease sites had higher rates of resimulation. Brain (P = .001) and lung/thorax (P = .008) had lower rates of resimulation. The most common causes for resimulation were setup change (11.7%), change in patient anatomy (9.8%), and rectal filling (8.5%). The resimulation rate for 4DCTs was 3.03% compared with 1.0% for non-4DCTs (P < .001). Median time between simulations was 7 days. The most common sites for resimulation were anal/colorectal and head and neck, largely because of change in setup or changes in anatomy. The 4DCT technique correlated with higher resimulation rates. The resimulation rate was 1.2%, and median treatment delay was 7 days. Further studies are warranted to limit the rate of resimulation.