19 November 2024 in Biomedical Optics Express
Photoacoustic computed tomography (PACT) has evoked extensive interest for applications in preclinical and clinical research. However, the current systems suffer from the limited view provided by detection setups, thus impeding the sufficient acquisition of intricate tissue structures. Here, we propose an approach to enable fast 3D full-view imaging. A hemispherical ultrasonic transducer array combined with a planar acoustic reflector serves as the ultrasonic detection device in the PACT system. The planar acoustic reflector can create a mirrored virtual transducer array, and the detection view range can be enlarged to cover approximately 3.7 π steradians in our detection setup. To verify the effectiveness of our proposed configuration, we present the imaging results of a hair phantom, an in vivo zebrafish larva, and a leaf skeleton phantom. Furthermore, the real-time dynamic imaging capacity of this system is demonstrated by observing the movement of zebrafish within 2 s. This strategy holds great potential for both preclinical and clinical research by providing more detailed and comprehensive images of biological tissues.
22 October 2025 in Laser & Photonics Reviews
1 April 2025 in Photonics Research
The integration of near-infrared genetically encoded reporters (NIR-GERs) with photoacoustic (PA) imaging enables visualizing deep-seated functions of specific cell populations at high resolution, though the imaging depth is primarily constrained by reporters’ PA response intensity. Directed evolution can optimize NIR-GERs’ performance for PA imaging, yet precise quantifying of PA responses in mutant proteins expressed in E. coli colonies across iterative rounds poses challenges to the imaging speed and quantification capabilities of the screening platforms. Here, we present self-calibrated photoacoustic screening (SCAPAS), an imaging-based platform that can detect samples in parallel within 5 s (equivalent to 50 ms per colony), achieving a considerable quantification accuracy of approximately 2.8% and a quantification precision of about 6.47%. SCAPAS incorporates co-expressed reference proteins in sample preparation and employs a ring transducer array with switchable illumination for rapid, wide-field dual-wavelength PA imaging, enabling precisely calculating the PA response using the self-calibration method. Numerical simulations validated the image optimization strategy, quantification process, and noise robustness. Tests with co-expression samples confirmed SCAPAS’s superior screening speed and quantification capabilities. We believe that SCAPAS will facilitate the development of novel NIR-GERs suitable for PA imaging and has the potential to significantly impact the advancement of PA probes and molecular imaging.
26 June 2026 in Science Advances
As a powerful modality for biomedical research, photoacoustic computed tomography (PACT) offers the combination of optical specificity and acoustic penetration for in vivo visualization. However, its performance is limited by a trade-off between ultrasound detection aperture and sensitivity, compromising image contrast, resolution, and penetration depth. Here, we introduce three-dimensional aperture-driven photoacoustic tomography (3D-ADPAT) to overcome these limitations, synergistically combining a high–numerical-aperture focused ultrasonic transducer (HNA-FUT) with a phase-inverted focusing-equivalent reconstruction (PIFER) algorithm. This approach yields ~2.21-fold enhancement in spatial resolution and ~10-fold increase in contrast-to-noise ratio. 3D-ADPAT’s performance was validated through comprehensive simulations and phantom studies and further confirmed by in vivo whole-body imaging that resolved deep-seated anatomies and tracked small-molecule metabolic pathways. Furthermore, a barrel-shaped array–based 3D-ADPAT implementation was designed, supporting dynamic imaging within a large field of view or across variable spatiotemporal scales. In summary, 3D-ADPAT provides a powerful tool for advanced photoacoustic systems, promising to accelerate frontier biomedical research.
4 November 2026 in Research Square
Three-dimensional photoacoustic imaging (3D PAI) has shown great potential in preclinical studies and clinical applications, but sparse sensor arrays commonly limit both spatial sampling and the field of view (FOV). Freehand scanning could overcome these limitations through anatomy-adaptive scanning that extends spatial coverage and provides complementary views beyond the fixed array aperture, but its flexibility is conventionally constrained by the need for motor feedback or external pose tracking. Here we introduce PA-SfM, a tracker-free structure-from-motion (SfM) framework that recovers multiple poses directly from PA measurements, enabling freehand 3D PAI without external pose measurements. PA-SfM integrates a differentiable acoustic radiation model with hierarchical optimization and rigid array constraints to jointly estimate transformations between views and reconstruct 3D volumes. The performance of PA-SfM was demonstrated in numerical simulations, animal studies and human imaging experiments. Compared with motor encoder-based fusion of the mechanically scanned system, PA-SfM reduced vessel misalignment in expanded FOV reconstructions. Controlled quantitative validations yielded peak signal-to-noise ratio (PSNR) values over 40 dB and structural similarity index (SSIM) values about 0.98 relative to ground truth or known pose reference reconstructions. Freehand experiments further demonstrated robust pose recovery at high scan speeds, with inter-frame displacements of 9 mm at intervals of 0.1 s. These results support PA-SfM as a tracker-free approach to large-scale freehand 3D PAI and provide a basis for further evaluation in clinical settings.
1 January 2026 in BME Frontiers
Objective: This study aims to longitudinally monitor hepatic vascular remodeling and functional recovery during liver regeneration in mice using 3-dimensional panoramic photoacoustic computed tomography (3D-PanoPACT). Impact Statement: By enabling noninvasive, whole-organ spatiotemporal tracking within the same animal, this work establishes a novel imaging framework for staging organ regeneration and mapping vascular dynamics. Introduction: Hepatic vascular remodeling is critical for successful liver regeneration; however, existing imaging modalities lack the capacity for noninvasive, longitudinal, 3D characterization at the whole-organ scale. Methods: Male nude mice under isoflurane anesthesia underwent 70% partial hepatectomy or served as controls. A custom 3D-PanoPACT system performed continuous whole-organ imaging over 16 d. Quantitative vascular parameters, contrast clearance kinetics, and histological validation via hematoxylin and eosin and CD31 staining were assessed. Serum biochemical analyses independently evaluated hepatobiliary functional recovery. Results: 3D-PanoPACT delineated 3 temporally distinct vascular remodeling phases: proliferative (days 2 to 4), recovery (days 5 to 9), and remodeling (days 10 to 16). By day 16, regenerated livers exhibited no significant differences from normal controls in vascular volume, vessel length, mean diameter, or branching density, which was further confirmed by CD31 evaluation. While functional imaging showed a slightly delayed early peak enhancement, long-term metabolic clearance remained similar to that of normal controls. This functional recovery was independently corroborated by normal-like serum biochemical profiles at day 16. Conclusion: 3D-PanoPACT enables noninvasive, longitudinal tracking of hepatic regeneration. By delineating distinct morphological phases and complementing them with metabolic and biochemical validations, this framework effectively maps macroscopic vascular remodeling and confirms adequate functional recovery by day 16.