22 September 2018 in Journal of Radiation Research
Verified
Journal Article
Open access
PDF file
KSKi Hyuk Sung
Ki Hyuk Sung
YJYoung-Jun Jung
Young-Jun Jung
HCHyemi Cha
Hyemi Cha
CCChin Youb Chung
Chin Youb Chung
KLKisung Lee
Kisung Lee
MPMoon Seok Park
Moon Seok Park
This study investigated the effect of metallic tools on the scattered radiation dose delivered to surgeons’ radiosensitive organs while simulating hip surgery using C-arm fluoroscopy. Two phantoms, a pelvis and a Rando phantom, were used to simulate a patient and a surgeon in this study. Photoluminescence dosimeters were inserted into the Rando phantom in the positions of the eye, thyroid and gonad. A drill was positioned above the hip of the pelvis phantom or beside the pelvis phantom of the same height. For each drill location, the scattered radiation dose was measured when the angle to the operator phantom was 45°; this was repeated when the angle was 90°. The scattered radiation doses to the eye, thyroid and gonad when the drill was placed beside the pelvis phantom with 90° angulation to the operator phantom were significantly lower than the reference values and those when the drill was placed beside the pelvis phantom at a 45° angulation to the operator phantom. The scattered radiation doses to the eye and thyroid when the drill was placed above the hip were significantly lower than the references values. Of the four different scenarios, the scattered radiation doses to the eye, thyroid and gonad were lowest when the drill was placed beside the pelvis phantom with 90° angulation. This study showed that the scattered radiation doses to radiosensitive organs were affected by the location and angle of the metallic tools in relation to the operator. Therefore, orthopedic surgeons should consider the effect of metallic tools on the scattered radiation dose during intraoperative use of C-arm fluoroscopy.

28 February 2018 in Veterinarni Medicina
Verified
Journal Article
Open access
HOH. Oh
H. Oh
SSS. Sung
S. Sung
SLS. Lim
S. Lim
YJY. Jung
Y. Jung
YCY. Cho
Y. Cho
KLK. Lee
K. Lee
Articles | Veterinární medicína | Agricultural Journals

1 February 2020 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
YJYoung-Jun Jung
Young-Jun Jung
SJSanggoo Jeong
Sanggoo Jeong
EMEungi Min
Eungi Min
MKMinho Kim
Minho Kim
HLHakjae Lee
Hakjae Lee
KLKisung Lee
Kisung Lee

12 August 2016 in Journal of Radiological Protection
Verified
Journal Article
Closed access
PDF file
KSKi Hyuk Sung
Ki Hyuk Sung
YJYoung-Jun Jung
Young-Jun Jung
SKSoon-Sun Kwon
Soon-Sun Kwon
GLGye Wang Lee
Gye Wang Lee
CCChin Youb Chung
Chin Youb Chung
KLKisung Lee
Kisung Lee
The scattered radiation protector for mobile x-ray systems, Creative Valuable Protector-2, has been recently developed. However, there have been no studies investigating the effects of this device. We aim to investigate the effects of the scattered radiation protector on the equivalent doses from scattered radiation delivered to radiosensitive organs while simulating spine surgery using a C-arm fluoroscope. Chest and rando phantoms were used to simulate a patient and a surgeon in this study. The equivalent dose from scattered radiation to radiosensitive organs was measured in four different situations according to the use of the scattered radiation protector and the C-arm configuration. To compare the quality of the images with and without the scattered radiation protector, an acryl step phantom with five steps was used, and the contrast resolution of each step was calculated. The equivalent dose from the scattered radiation to the surgeon's eye, thyroid, and gonad decreased significantly by using the scattered radiation protector for both the Posteroanterior (PA) (p < 0.001) and Anteroposterior (AP) (p < 0.001) C-arm configurations. The installation of the scattered radiation protector also reduced the direct radiation dose to the chest phantom. A scattered map showed that scattered radiation doses decreased by approximately 50% for the PA configuration and 75% for the AP configuration by using the scattered radiation protector. Before and after installation of the scattered radiation protector, the contrast resolution of each adjacent step area was 0.025–0.404 and 0.216–0.421. The scattered radiation protector was effective in reducing not only the equivalent dose from scattered radiation to the surgeon's radiosensitive organs, but also the direct radiation dose to the patient. This was all achieved without decreasing the quality of the C-arm fluoroscopic images.

1 October 2011
Verified
Conference Paper
Closed access
YJYoung-Jun Jung
Young-Jun Jung
KKKyeongMin Kim
KyeongMin Kim
JKJinSu Kim
JinSu Kim
SWSang-Keun Woo
Sang-Keun Woo
JPJiAe Park
JiAe Park
JKJongguk Kim
Jongguk Kim
We investigated optimized collimator designs for I-131 high energy gamma ray imaging on small animal gamma camera. The simulated structures of the pinhole collimator were evaluated by sensitivity, true, scatter and penetration count rates, and spatial resolution. The parameters, which were pinhole diameter, acceptance angle, and aperture thickness, were determined to improve image resolution with geometric conditions. In this study we showed optimized pinhole design for high energy I-131 imaging to meet the tradeoff between sensitivity and resolution..

1 January 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
HCHyemi Cha
Hyemi Cha
KCKyeyoung Cho
Kyeyoung Cho
YJYoung-Jun Jung
Young-Jun Jung
SBSeungbin Bae
Seungbin Bae
KKKyeong Min Kim
Kyeong Min Kim
KLKisung Lee
Kisung Lee