Christoph Hennersperger

Christoph Hennersperger

Auto-generated profile, based on publicly available information

Christoph Hennersperger

Computer Aided Medical Procedures Technische Universität München Germany

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 October 2016 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
CHChristoph Hennersperger
Christoph Hennersperger
BFBernhard Fuerst
Bernhard Fuerst
SVSalvatore Virga
Salvatore Virga
OZOliver Zettinig
Oliver Zettinig
BFBenjamin Frisch
Benjamin Frisch
NNNassir Navab
Nassir Navab
Robotic ultrasound has the potential to assist and guide physicians during interventions. In this work, we present a set of methods and a workflow to enable autonomous MRI-guided ultrasound acquisitions. Our approach uses a structured-light 3D scanner for patient-to-robot and image-to-patient calibration, which in turn is used to plan 3D ultrasound trajectories. These MRI-based trajectories are followed autonomously by the robot and are further refined online using automatic MRI/US registration. Despite the low spatial resolution of structured light scanners, the initial planned acquisition path can be followed with an accuracy of 2.46 ± 0.96 mm. This leads to a good initialization of the MRI/US registration: the 3D-scan-based alignment for planning and acquisition shows an accuracy (distance between planned ultrasound and MRI) of 4.47 mm, and 0.97 mm after an online-update of the calibration based on a closed loop registration.

9 June 2015 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
OZOliver Zettinig
Oliver Zettinig
ASAmit Shah
Amit Shah
CHChristoph Hennersperger
Christoph Hennersperger
MEMatthias Eiber
Matthias Eiber
CKChristine Kroll
Christine Kroll
NNNassir Navab
Nassir Navab

1 May 2016
Verified
Conference Paper
Closed access
CGChristoph Graumann
Christoph Graumann
BFBernhard Fuerst
Bernhard Fuerst
CHChristoph Hennersperger
Christoph Hennersperger
FBFelix Bork
Felix Bork
NNNassir Navab
Nassir Navab
Medical robotic ultrasound offers potential to assist interventions, ease long-term monitoring and reduce operator dependency. Various techniques for remote control of ultrasound probes through telemanipulation systems have been presented in the past, however not exploiting the potential of fully autonomous acquisitions directly performed by robotic systems. In this paper, a trajectory planning algorithm for automatic robotic ultrasound acquisition under expert supervision is introduced. The objective is to compute a suitable path for covering a volume of interest selected in diagnostic images, for example by prior segmentation. A 3D patient surface point cloud is acquired using a depth camera, which is the sole prerequisite besides the volume delineation. An easily parameterizable path function generates single or multiple parallel scan trajectories capable of dealing with large target volumes. A spline is generated through the preliminary path points and is transferred to a lightweight robot to perform the ultrasound scan using an impedance control mode. The proposed approach is validated via simulation as well as on phantoms and on animal viscera.

8 April 2017 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
MRMarco Riva
Marco Riva
CHChristoph Hennersperger
Christoph Hennersperger
FMFausto Milletari
Fausto Milletari
AKAmin Katouzian
Amin Katouzian
FPFederico Pessina
Federico Pessina
LBLorenzo Bello
Lorenzo Bello

1 October 2016 in Medical Image Analysis
Verified
Journal Article
Closed access
NNNassir Navab
Nassir Navab
MFMiccai Fellow
Miccai Fellow
CHChristoph Hennersperger
Christoph Hennersperger
BFBenjamin Frisch
Benjamin Frisch
BFBernhard Fürst
Bernhard Fürst

6 April 2016 in Clinical Hemorheology and Microcirculation
Verified
Journal Article
Closed access
PDF file
KPKarin Pfister
Karin Pfister
WSWilma Schierling
Wilma Schierling
EJErnst Michael Jung
Ernst Michael Jung
HAHanna Apfelbeck
Hanna Apfelbeck
CHChristoph Hennersperger
Christoph Hennersperger
PKPiotr M. Kasprzak
Piotr M. Kasprzak
PURPOSE: To compare standardised 2D ultrasound (US) to the novel ultrasonographic imaging techniques 3D/4D US and image fusion (combined real-time display of B mode and CT scan) for routine measurement of aortic diameter in follow-up after endovascul