Robotic ultrasound has the potential to assist and guide physicians during interventions. In this work, we present a set of methods and a workflow to enable autonomous MRI-guided ultrasound acquisitions. Our approach uses a structured-light 3D scanner for patient-to-robot and image-to-patient calibration, which in turn is used to plan 3D ultrasound trajectories. These MRI-based trajectories are followed autonomously by the robot and are further refined online using automatic MRI/US registration. Despite the low spatial resolution of structured light scanners, the initial planned acquisition path can be followed with an accuracy of 2.46 ± 0.96 mm. This leads to a good initialization of the MRI/US registration: the 3D-scan-based alignment for planning and acquisition shows an accuracy (distance between planned ultrasound and MRI) of 4.47 mm, and 0.97 mm after an online-update of the calibration based on a closed loop registration.
9 June 2015 in International Journal of Computer Assisted Radiology and Surgery
Medical robotic ultrasound offers potential to assist interventions, ease long-term monitoring and reduce operator dependency. Various techniques for remote control of ultrasound probes through telemanipulation systems have been presented in the past, however not exploiting the potential of fully autonomous acquisitions directly performed by robotic systems. In this paper, a trajectory planning algorithm for automatic robotic ultrasound acquisition under expert supervision is introduced. The objective is to compute a suitable path for covering a volume of interest selected in diagnostic images, for example by prior segmentation. A 3D patient surface point cloud is acquired using a depth camera, which is the sole prerequisite besides the volume delineation. An easily parameterizable path function generates single or multiple parallel scan trajectories capable of dealing with large target volumes. A spline is generated through the preliminary path points and is transferred to a lightweight robot to perform the ultrasound scan using an impedance control mode. The proposed approach is validated via simulation as well as on phantoms and on animal viscera.
8 April 2017 in International Journal of Computer Assisted Radiology and Surgery
PURPOSE: To compare standardised 2D ultrasound (US) to the novel ultrasonographic imaging techniques 3D/4D US and image fusion (combined real-time display of B mode and CT scan) for routine measurement of aortic diameter in follow-up after endovascul