Dongmyoung Joo

Dongmyoung Joo

Auto-generated profile, based on publicly available information

Dongmyoung Joo

Power System Research Center, Korea Electronics Technology Institute, Seongnam, Republic of Korea

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2019 in Energies
Verified
Journal Article
Open access
PDF file
Sang Min ParkSang Min Park
Sang Min Park
EJEunsu Jang
Eunsu Jang
DJDongmyoung Joo
Dongmyoung Joo
Byoung Kuk LeeByoung Kuk Lee
Byoung Kuk Lee
Typical domestic induction cooktops can only heat ferromagnetic pots/vessels. However, to increase the availability and marketability of induction heating (IH) cooktop products, heating techniques for all types of metallic pots (i.e., created from metals such as aluminum, copper, and stainless steel) are required. To satisfy the requirements of induction cooktops, this paper proposes the design of an all-metal domestic IH system that can heat any type of metallic pot while considering the temperature variation of the working-coil. A control algorithm using a power curve-fitting method (CFM) is presented to quickly respond to load parameter variations in the IH. In addition, the CFM control algorithm is established to compensate for the power reference value by reflecting the increase in the working-coil temperature during the heating of the non-ferromagnetic pot. To evaluate the performance of the proposed system, the control algorithm strategy and experimental results based on a 3.2 kW all-metal IH cooktop are presented.

4 April 2016 in Electronics Letters
Verified
Journal Article
Open access
PDF file
DJD.M. Joo
D.M. Joo
BLB.K. Lee
B.K. Lee
JKJong-Soo Kim
Jong-Soo Kim
An accurate dead‐time adjustment method for phase‐shifted full bridge (PSFB) converter is presented. This method allows the dead‐time of converters to be optimised to meet zero voltage switching condition. The optimum dead‐time range can be predicted with high accuracy for any type of power semiconductor switch, including gallium nitride high‐electron‐mobility transistor, so that a practical design for a PSFB converter can be realised. The validity of the proposed dead‐time optimisation method was verified by experimental results with a 600 W prototype.

1 November 2017 in Electronics Letters
Verified
Journal Article
Open access
PDF file
DJD.M. Joo
D.M. Joo
JBJ.E. Byun
J.E. Byun
BLB.K. Lee
B.K. Lee
JKJong-Soo Kim
Jong-Soo Kim
An adaptive delay control method for a phase‐shifted full bridge converter with a synchronous rectifier is presented. With this control, the delay time between primary and secondary switches can be optimised to reduce dead time, according to output power. Moreover, due to the poor third quadrant conduction of gallium nitride (GaN) high‐electron‐mobility transistors (HEMTs), the dead time needs to be optimised to utilise the benefits of a GaN HEMT. The experimental results with a 500 W prototype show that the efficiency can be improved by 0.7% with the proposed control.

7 January 2019 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
DJDongmyoung Joo
Dongmyoung Joo
HKHyun-Bin Kim
Hyun-Bin Kim
Byoung Kuk LeeByoung Kuk Lee
Byoung Kuk Lee
JKJong-Soo Kim
Jong-Soo Kim

11 August 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JLJu-A Lee
Ju-A Lee
DJDongmyoung Joo
Dongmyoung Joo
CKChae-Lyn Kim
Chae-Lyn Kim
DSDong Hyeon Sim
Dong Hyeon Sim
BLByoung Kuk Lee
Byoung Kuk Lee
The demand for high-power dc fast chargers has increased to reduce electric vehicle charging time, driving the active adoption of power modules to enhance charger power capacity. As the power capacity per module increases and the number of parallel modules decreases, the overall system volume and cost are reduced. Thus, the development of high-power modules has become increasingly important. Therefore, this article provides practical guidelines for implementing a 50 kW three-phase power factor correction (PFC) converter, commonly used as an ac–dc converter module in dc fast charger. A quantitative analysis of the volume, performance, cost, and efficiency of different filter types for a three-phase PFC designed under identical conditions is conducted, providing selection criteria based on design priorities. Additionally, a stable startup method using feedforward compensation is proposed to regulate the inrush current. The effects of gain variations on steady-state and dynamic characteristics, along with current total harmonic distortion (THD), are analyzed. Furthermore, hardware implementation and thermal design considerations for the reliable parallel operation of SiC mosfets are presented. As a result, the implemented three-phase PFC converter achieves a maximum efficiency of 98.65% and an efficiency of 97.10% under full-load conditions, while maintaining a current THD within 5% in the primary operating range.

23 May 2019 in Energies
Verified
Journal Article
Open access
PDF file
GKGeun Wan Koo
Geun Wan Koo
DJDongMyoung Joo
DongMyoung Joo
Byoung Kuk LeeByoung Kuk Lee
Byoung Kuk Lee
The resilience of systems with alternating current (AC)–direct current (DC) converters has been investigated with the aim of improving switch fault diagnosis. To satisfy this aim, this paper proposes a switch fault diagnosis algorithm for three-phase AC–DC converters. The proposed algorithm operates using the phase current instead of the average current to reduce the calculation time required for fault switch detection. Moreover, a threshold point calculation method is derived using a theoretical analysis, which was lacking in previous research. Using the calculated threshold point, a switch fault diagnosis algorithm is obtained to detect faults independent of the load condition. Using the proposed algorithm, switch faults can be detected within 4 ms, which is the recommended value for uninterruptible power supply (UPS). The theoretical analysis, the operating principle, and the experimental results on a 3-kW grid-tied AC–DC converter test-bed are presented herein, which verify the performance of the proposed algorithm.