6 March 2018 in Applied Optics
Near-infrared imaging (NIRI) is a sub-surface imaging that makes a trade-off in recovery accuracy with depth of penetration. On the other hand, diffuse optical tomography (DOT) images tissue up to several centimeters. However, DOT reconstruction has a stability issue due to the inverse problem. This paper proposes a generalized continuous-wave technique to image objects of dimensions 4–6 cm comparable to DOT. A nonlinear Rosenbrock’s banana function is fitted to the approximate photon path, and the fit parameter thus obtained gives the penetration depth of each channel. The calculated values of absorption change are back-projected along these curved paths for reconstruction without solving the inverse problem. This function serves as an operator for image reconstruction. Here numerical simulations, experimental validation on wax phantom with inclusions, finger joint, and degraded apple have been performed to show potential of the proposed method in imaging. Thus this computationally efficient, reliable, and simple method is suitable for practical and real-time NIRI applications.
1 March 2018 in Optics Communications
6 March 2020 in IEEE Transactions on Instrumentation and Measurement
This paper presents a promising dual-wavelength continuous wave (CW) diffuse optical tomography (DOT) system for direct estimation of concentrations and hemodynamic parameters for potential application in detection of rheumatoid arthritis (RA). The generalized curved-beam reconstruction technique is modified for direct estimation of hemodynamic parameters. The Rosenbrock’s function is fitted to estimate the photon path as curved one followed by majority photons that enabled the use of modified Beer-Lambert law (MBLL) in differential form with assumption that unknown absorption coefficient (la) varies from one path to another. The la values are calculated and back-projected along the photon paths for image reconstruction without solving the inverse problem. Thus, stability is not an issue in image reconstruction. Also, there is no need for baseline measurement and prior information on perturbation, unlike the iterative methods used for dynamic imaging. The reconstructed images of the distal interphalangeal (DIP) and proximal interphalangeal (PIP) joints of a healthy male volunteer showed good consistency and are used for direct optical estimation of the physiological parameters. A novel application of optical imaging beyond biomedical applications is demonstrated by imaging the gradual dispersion of viscous Indian ink and glycerin mixture in turbid water with encouraging results.
31 October 2023 in IEEE Sensors Journal
A novel non-linear semi-analytic reconstruction method for continuous-wave diffuse optical tomography (CW-DOT) that employs a Gaussian distribution framework for tracing photon paths is presented here in this work. In highly scattering media-like tissue, photons travel on a curved photon path with cloud distribution between any light source–detector pairs. In this work, Gaussian distributed Rosenbrock’s banana function was utilized to trace the majority of photons between any source–detector pairs as curved paths with photon cloud distribution to mimic the actual photon distributions. This has led to a more realistic semi-analytic diffuse optical tomographic reconstruction technique and helped to improve the reconstruction accuracy significantly. This improved method is experimentally validated on multiple inclusion wax phantom and in vivo finger joint imaging of a healthy volunteer. Also, the proposed reconstruction method can directly estimate the tissue oxygenation level measured in terms of oxygen saturation (StO2) and oxygen capacity ( ${C}_{B}$ ) in vivo derived from hemoglobin concentrations using CW-DOT. Tissue oxygenation levels and oxygen capacities were estimated consistently and accurately. The results showed significant improvement in accuracy when compared to the generalized method where the photon paths are modeled as curved lines, estimated by different performance evaluation matrices.