Dharitri Goswami

Dharitri Goswami

Auto-generated profile, based on publicly available information

Dharitri Goswami

B C Roy Technology Hospital, Indian Institute of Technology Kharagpur, Kharagpur, India

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 July 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ACAyan Chakraborty
Ayan Chakraborty
DGDharitri Goswami
Dharitri Goswami
JMJayanta Mukhopadhyay
Jayanta Mukhopadhyay
SCSaswat Chakrabarti
Saswat Chakrabarti
Measurement of blood pressure from photoplethysmograph (PPG) signal has been investigated by several researchers in recent years. Use of PPG signal for blood pressure measurement has advantages over conventional cuff-based sphygmomanometric methods. Signals from two different measurement instruments such as electrocardiogram (ECG) and photoplethysmogram are mostly used to determine blood pressure. In this paper a novel approach for determining blood pressure by measurement of only one signal viz. PPG, is presented. Two specific methods have been discussed for determining mean arterial blood pressure (MABP), systolic blood pressure (SBP) and diastolic blood pressure (DBP). The first method, presented in Section III, needs an initial value of blood pressure while the second method uses a learning based non-parametric regression technique. PPG signals from more than 150 volunteers have been used to assess the blood pressure. Mean and standard deviation of error magnitudes in measuring DBP is 2.12 ± 1.79 mmHg.

15 September 2023 in IEEE Transactions on Consumer Electronics
Verified
Journal Article
Closed access
ACAyan Chakraborty
Ayan Chakraborty
DGDharitri Goswami
Dharitri Goswami
JMJayanta Mukhopadhyay
Jayanta Mukhopadhyay
SCSaswat Chakrabarti
Saswat Chakrabarti
Cuff-less BP measurement methods suitable for IoT applications have been of specific interest for researchers of late. However, most of the methods are based on use of electrocardiograph (ECG) signal along with PPG signal or using extensive learning and artificial intelligence (AI). In this paper two features of the PPG signal viz. peak to peak amplitude (vPP) and foot to foot delay (D) have been used to measure first the diastolic blood pressure (PD) and then the systolic blood pressure (PS). A novel expression is derived from Beer Lambert’s law to relate PD with vPP. A two-pulse-synthesis (TPS) model is used to decompose a PPG pulse using two Rayleigh functions and foot to foot delay is extracted. PS has been obtained using D. The method has been tested on 31 volunteers and 150 diseased subjects from MIMIC III waveform database. Mean absolute error of PS and PD for MIMIC III database are 3.63 mmHg and 2.28 mmHg respectively which are very much comparable to other popular calibration based methods reported in the literature. This lightweight method may be suitable for personalized healthcare.