Jae-Woo Ju

Jae-Woo Ju

Auto-generated profile, based on publicly available information

Jae-Woo Ju

Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2015 in Anaesthesia and Intensive Care
Verified
Journal Article
Open access
PDF file
HLHannah Lee
Hannah Lee
CLC. W. Lim
C. W. Lim
HHH. P. Hong
H. P. Hong
JJJ. W. Ju
J. W. Ju
YJY. T. Jeon
Y. T. Jeon
HPHee-Pyoung Park
Hee-Pyoung Park
In this study, we evaluated the efficacy of the discharge Acute Physiology and Chronic Health Evaluation (APACHE) II score in predicting post-intensive care unit (ICU) mortality and ICU readmission during the same hospitalisation in a surgical ICU. Of 1190 patients who were admitted to the ICU and stayed >48 hours between October 2007 and March 2010, 23 (1.9%) died and 86 (7.2%) were readmitted after initial ICU discharge, with 26 (3.0%) admitted within 48 hours. The area under the receiver operating characteristics curve of the discharge and admission APACHE II scores in predicting in-hospital mortality was 0.631 (95% confidence interval [CI] 0.603 to 0.658) and 0.669 (95% CI 0.642 to 0.696), respectively (P=0.510). The area under the receiver operating characteristics curve of discharge and admission APACHE II scores for predicting all forms of readmission was 0.606 (95% CI 0.578 to 0.634) and 0.574 (95% CI 0.545 to 0.602), respectively (P=0.316). The area under the receiver operating characteristics curve of discharge APACHE II score in predicting early ICU readmissions was, however, higher than that of admission APACHE II score (0.688 [95% CI 0.660 to 0.714] versus 0.505 [95% CI 0.476 to 0.534], P=0.001). The discharge APACHE II score (odds ratio [OR] 1.1, 95% CI 1.01 to 1.22, P=0.024), unplanned ICU readmission (OR 20.0, 95% CI 7.6 to 53.1, P=0.001), eosinopenia at ICU discharge (OR 6.0, 95% CI 1.34 to 26.9, P=0.019), and hospital length-of-stay before ICU admission (OR 1.02, 95% CI 1.01 to 1.03, P=0.021) were significant independent factors in predicting post-ICU mortality. This study suggests that the discharge APACHE II score may be useful in predicting post-ICU mortality and is superior to the admission APACHE II score in predicting early ICU readmission in surgical ICU patients.

1 July 2018 in Surgery
Verified
Journal Article
Open access
HLHannah Lee
Hannah Lee
JJJae-Woo Ju
Jae-Woo Ju
SOSeung-Young Oh
Seung-Young Oh
JKJeongsoo Kim
Jeongsoo Kim
CJChul Jung
Chul Jung
HRHo-Geol Ryu
Ho-Geol Ryu
Recent reports suggest that not all critically ill patients with delirium share the same consequences. The outcomes of surgical intensive care unit patients with postoperative delirium were evaluated depending on the onset and duration of delirium. A total of 527 patients who were admitted from the operating theater and cared for in the surgical intensive care unit for >24 hours were evaluated for delirium using the Confusion Assessment Method for intensive care unit, 3 times a day. Patients were analyzed according to the onset time and duration of delirium. Patients were classified into 4 groups according to the onset and duration of delirium: no delirium, early brief delirium (delirium for <1 day on postoperative day 0), late brief delirium (delirium for 24 hours (persistent). Persistent delirium was associated with longer intensive care unit (4.6 [1.1-53.3] vs 1.6 [1.1-37.5] days) and hospital duration of stay (24 [3-112] vs 16 [2-225] days) and higher hospital mortality (14.5% vs 2.2%) compared to no delirium (P < .01). For postoperative intensive care unit patients, intensive care unit and hospital duration of stay did not seem to differ between patients with early brief delirium or no delirium, whereas patients with late brief or persistent delirium seemed to show longer intensive care unit and hospital duration of stay and higher mortality.

1 August 2021 in Journal of Cardiothoracic and Vascular Anesthesia
Verified
Journal Article
Closed access
PDF file
JBJinyoung Bae
Jinyoung Bae
JKJay Kim
Jay Kim
SLSeohee Lee
Seohee Lee
JJJae-Woo Ju
Jae-Woo Ju
YCYoun Joung Cho
Youn Joung Cho
KNKaram Nam
Karam Nam

1 May 2016 in European Journal of Anaesthesiology
Verified
Journal Article
Closed access
YCYoun J. Cho
Youn J. Cho
JJJae W. Ju
Jae W. Ju
HSHyunyee Sim
Hyunyee Sim
JLJong-Hwan Lee
Jong-Hwan Lee
DHDeok M. Hong
Deok M. Hong
YJYunseok Jeon
Yunseok Jeon
Intraoperative anaphylaxis to neuromuscular blocking agents (NMBAs) is a rare event that is unpredictable and potentially life threatening. Most of the previous reports on such intraoperative anaphylaxis used market share surveys or self-reported data to estimate the incidence. To determine the incidences of intraoperative anaphylaxis to NMBAs using electronic medical records. A retrospective observational study. Two tertiary hospitals in South Korea. This study involved patients exposed to NMBAs during anaesthesia between 1 January 2005 and 31 May 2014. Nineteen episodes were deemed to be intraoperative anaphylaxis to NMBAs. We calculated the incidences of intraoperative anaphylaxis to NMBAs. Exposure to the agents was determined from intraoperative records maintained in an electronic medical recording system. An anaphylactic reaction was determined from both clinical signs and the results of skin tests. Over 9 years, 729 429 patients were exposed to NMBA, the most frequently used being rocuronium [425 047 (58.3%)] and vecuronium [274 801 (37.7%)]. The overall incidence of intraoperative anaphylaxis was 2.6 per 100 000 (19 cases), and was higher with rocuronium (16 cases, 3.8 per 100 000) than with vecuronium (two cases, 0.7 cases per 100 000), P = 0.014. Comparing the first 3 years with the last 6 years, the incidence of intraoperative rocuronium anaphylaxis appeared to increase 1.4-fold (P = 0.006). Among commonly used NMBAs, rocuronium appears to have the highest incidence of anaphylaxis. Our findings suggest that future prospective investigation for NMBA-induced anaphylaxis should use internationally agreed skin test protocols.

26 June 2021 in Journal of Hepato-Biliary-Pancreatic Sciences
Verified
Journal Article
Closed access
PDF file
JJJae‐Woo Ju
Jae‐Woo Ju
SPSo Jung Park
So Jung Park
SYSusie Yoon
Susie Yoon
HLHo-Jin Lee
Ho-Jin Lee
HKHongbeom Kim
Hongbeom Kim
JJJin‑Young Jang
Jin‑Young Jang

1 August 2015 in European Journal of Anaesthesiology
Verified
Journal Article
Closed access
TKTae Kyong Kim
Tae Kyong Kim
JMJeong Jin Min
Jeong Jin Min
JSJeong-Hwa Seo
Jeong-Hwa Seo
YLYong-Hun Lee
Yong-Hun Lee
JJJae-Woo Ju
Jae-Woo Ju
YJYunseok Jeon
Yunseok Jeon
Excessive tracheal cuff pressure reduces tracheal mucosal blood flow and increases tracheal morbidity. Inserting a transoesophageal echocardiography (TOE) probe has been shown to increase tracheal cuff pressure. To evaluate the effect of inserting a TOE probe on tracheal cuff pressure and compare the effect in patients who received a single-lumen endotracheal tube (SLT) with those who received a double-lumen endotracheal tube (DLT). A prospective, observational study. Single-centre trial, study period from October 2013 to January 2014. Forty-four adult patients scheduled for elective cardiothoracic surgery requiring intraoperative TOE monitoring. After tracheal intubation with a SLT (n = 22) or DLT (n = 22), the tracheal cuff was inflated to 18 mmHg (25 cmH2O) with air. Tracheal cuff pressure was monitored continuously for 5 min after inserting the TOE probe. The primary endpoint was steady-state tracheal cuff pressure after insertion of the TOE probe. Median (interquartile range, IQR) tracheal cuff pressure stabilised at 3 (2 to 3) min in the SLT group and at 2 (1 to 3) min in the DLT group. Steady-state cuff pressure was significantly higher in the DLT group than that in the SLT group [36.7 (31.3 to 44.1) vs. 31.3 (29.6 to 35.7) cmH2O; (P = 0.03)]. Steady-state cuff pressure more than 40 cmH2O was observed in two patients (18.2%) in the SLT group and nine patients (40.9%) in the DLT group (P = 0.02). Insertion of a TOE probe increased tracheal cuff pressure in both the SLT and DLT groups. The increase in cuff pressure was greater in patients who received a DLT. Frequent measurement and adjustment of cuff pressure should be emphasised particularly when TOE is used in patients receiving a DLT. Clinicaltrials.gov identifier: NCT02034643.