10 February 2021 in IEEE Transactions on Instrumentation and Measurement
This article introduces a bias controllable integrated optics electric field measurement system fabricated by LiNbO3 (LN) that can be used for the measurement of 10-kV/m subnanosecond rise time electromagnetic pulse (EMP). Combined with the structure of birefringence modulation (BRM) and the 1550-nm tunable laser, this probe has simple structure measures 1.5 cm $\times 2$ cm $\times4.5$ cm. It realized the set of bias to any value during $2\pi $ with less than 1-nm change of the wavelength of the tunable laser, despite the influence of the environment. Furthermore, an optimal bias automatic feedback controller based on Newton iteration algorithm is constructed to lock the bias at a fixed point. The statistical result (average ± standard deviation) of the bias under controlled is 90.4 ± 0.8°. Calibrated results show that it shows consistent response to the pulse with rise time of 200 ps, and the minimum and maximum measurement amplitude is 0.3 and 45 kV/m, respectively.
3 December 2021 in IEEE Transactions on Nuclear Science
A system-generated electromagnetic pulse (SGEMP) occurs when the system is exposed to an X-ray or γ-ray beam. And the presence of air will greatly alter the fields of SGEMP. In this article, one-dimensional simulations are performed with a newly developed relativistic swarm model to investigate the air effects on SGEMP. For comparing, the equilibrium model and the non-relativistic swarm model are also used in simulations. The simulation results are divided into different pressure regions for discussion, i.e., the high pressure region (I and II), the transition region, and the intermediate pressure region. In the high pressure region, the air plasma will dramatically reduce the electric field generated by primary current. And the electric field increases with decreasing air density in high pressure region I, due to the decreases of the ionization source of primary electrons interacting with air molecules. Then the electric field decreases with decreasing air density in high pressure region II, mainly because of cascading ionization begins to dominate the generation of secondary electrons. In the transition region, the electric field is reduced to a minimal level, as the cascading rate saturates with the increase of electron energy. As air density continues to decrease, the electric field rises again and begins to oscillate in the intermediate region, where the relativistic effect becomes important. This investigation will be helpful in understanding future results of both experiment and simulation.
14 July 2020 in IEEE Transactions on Electromagnetic Compatibility
In high-altitude electromagnetic pulse (HEMP) field tests, coupling currents under a given illuminated electromagnetic field are important to the design of electronic systems and electromagnetic (EM) shielding. Compared to calculating the arithmetic average (AA) of the amplitude of coupling currents, reference field normalization (RFN) method is a data processing method of HEMP field tests studied in this article. In this method, a reference field is introduced and measured during each repeated illumination of the HEMP field test to minimize the impact of deviations of the illuminated EM field produced by a HEMP simulator. To evaluate the RFN method, uncertainty analysis is carried out. Then the uncertainty and relative error are calculated and compared between the RFN method and the AA method by the coupling currents data both from Monte Carlo method and real test. The results show that the RFN method has a better performance compared to the AA method both from the aspect of uncertainty and relative error.
12 August 2021 in IEEE Transactions on Electromagnetic Compatibility
When designing an electromagnetic enclosure, coupling electric fields under a given simulated high-altitude electromagnetic pulse (HEMP) field are commonly measured in HEMP field tests. Different from calculating the arithmetic average (AA) of the amplitude of the measurements, the reference field normalization (RFN) data processing method processes the measurements with the reference field to reduce the impact of deviations of the simulated HEMP field. This article mainly analysis the uncertainty of the coupling electric fields processed by the RFN method in HEMP field tests. The coupling electric fields data obtained from the Monte Carlo method and real test are used to compare the RFN method with the AA method. The uncertainty and relative error are then analyzed. The results show that the RFN method has better performance than the AA method.
1 August 2020 in IEEE Transactions on Electromagnetic Compatibility
9 November 2023 in IEEE Transactions on Electromagnetic Compatibility
In many instances, single unipolar electromagnetic pulse follows a double exponential behavior. Bandwidth requirements for the double exponential pulse measurement need to be estimated to guide the selection of proportional wideband sensors. To this end, measurement procedure is simulated in this article. The sensors are modeled as a cascade of a high-pass and a low-pass filter. The scaled double exponential pulses are set as input. Then, the relationship between the relative error of the shape parameters of the measured pulse and the scaled cutoff frequencies is deduced. Based on the relationship curves, two simple formulas are summarized for the testers on site to estimate the bandwidth requirements according to the prior information about the pulse to be measured. The experimental results are also presented in support of the proposed formulas.