T. Watari

T. Watari

Auto-generated profile, based on publicly available information

T. Watari

National Institute for Fusion Science, Toki, Gifu 509-5292, Japan

Research Focus & Metrics

Academic Career Length

45Years (1982-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2001 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Closed access
PDF file
HYH Yamada
H Yamada
AKA Komori
A Komori
NON Ohyabu
N Ohyabu
OKO Kaneko
O Kaneko
KKK Kawahata
K Kawahata
MFM Fujiwara
M Fujiwara
Recent experimental results in the Large Helical Device have indicated that a large pressure gradient can be formed beyond the stability criterion for the Mercier (high-n) mode. While the stability against an interchange mode is violated in the inward-shifted configuration due to an enhancement of the magnetic hill, the neoclassical transport and confinement of high-energy particle are, in contrast, improved by this inward shift. Mitigation of the unfavourable effects of MHD instability has led to a significant extension of the operational regime. Achievements of the stored energy of 1 MJ and the volume-averaged beta of 3% are representative results from this finding. A confinement enhancement factor above the international stellarator scaling ISS95 is also maintained around 1.5 towards a volume-averaged beta, β , of 3%. Configuration studies on confinement and MHD characteristics emphasize the superiority of the inward-shifted geometry to other geometries. The emergence of coherent modes appears to be consistent with the linear ideal MHD theory; however, the inward-shifted configuration has reduced heat transport in spite of a larger amplitude of magnetic fluctuation than the outward-shifted configuration. While neoclassical helical ripple transport becomes visible for the outward-shifted configuration in the collisionless regime, the inward-shifted configuration does not show any degradation of confinement deep in the collisionless regime (ν*<0.1). The distinguished characteristics observed in the inward-shifted configuration help in creating a new perspective of MHD stability and related transport in net current-free plasmas. The first result of the pellet launching at different locations is also reported.

26 January 2005 in Nuclear Fusion
Verified
Journal Article
Closed access
YHY Hamada
Y Hamada
ANA Nishizawa
A Nishizawa
TIT Ido
T Ido
TWT Watari
T Watari
MKM Kojima
M Kojima
JGJIPPT-IIU Group
JIPPT-IIU Group

1 April 2001 in Nuclear Fusion
Verified
Journal Article
Open access
PDF file
RSR. Sakamoto
R. Sakamoto
HYH. Yamada
H. Yamada
KTK. Tanaka
K. Tanaka
KNK. Narihara
K. Narihara
SMS. Morita
S. Morita
MFM. Fujiwara
M. Fujiwara
Pellet injection has been used as a primary fuelling scheme in the Large Helical Device. With pellet injection, the operational region of NBI plasmas has been extended to higher densities while maintaining a favourable dependence of energy confinement on density, and several important values, such as plasma stored energy of 0.88 MJ, energy confinement time of 0.3 s, β of 2.4% at 1.3 T and density of 1.1 × 1020 m -3, have been achieved. These parameters cannot be attained by gas puffing. Ablation and the subsequent behaviour of the plasma have been investigated. The measured pellet penetration depth estimated on the basis of the duration of the Hα emission is shallower than the depth predicted from the simple neutral gas shielding (NGS) model. It can be explained by the NGS model with inclusion of the effect of fast ions on the ablation. Just after ablation, the redistribution of the ablated pellet mass was observed on a short timescale (~400 ms). The redistribution causes shallow deposition and low fuelling efficiency.

30 May 2003 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Closed access
PDF file
TST Shimozuma
T Shimozuma
SKS Kubo
S Kubo
HIH Idei
H Idei
YYY Yoshimura
Y Yoshimura
TNT Notake
T Notake
TGthe LHD Experimental Group
the LHD Experimental Group
Internal transport barriers with respect to electron thermal transport (eITB) were observed in the large helical device, when the electron cyclotron resonance heating (ECH) power was highly localized on the centre of a plasma sustained by neutral beam injection. The eITB is characterized by a high central electron temperature of 6–8 keV with an extremely steep gradient, as high as 55 keV m−1 and a low electron thermal diffusivity within a normalized average radius ρ≈0.3 as well as by the existence of clear thresholds for the ECH power and plasma collisionality.

22 April 2003 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
YTY. Takeiri
Y. Takeiri
TST. Shimozuma
T. Shimozuma
SKS. Kubo
S. Kubo
SMS. Morita
S. Morita
MOM. Osakabe
M. Osakabe
HNH. Nozato
H. Nozato
An internal transport barrier (ITB) was observed in the electron temperature profile in the Large Helical Device [O. Motojima et al., Phys. Plasmas 6, 1843 (1999)] with a centrally focused intense electron cyclotron resonance microwave heating. Inside the ITB the core electron transport was improved, and a high electron temperature, exceeding 10 keV in a low density, was achieved in a collisionless regime. The formation of the electron-ITB is correlated with the neoclassical electron root with a strong radial electric field determined by the neoclassical ambipolar flux. The direction of the tangentially injected beam-driven current has an influence on the electron-ITB formation. For the counter-injected target plasma, a steeper temperature gradient, than that for the co-injected one, was observed. As for the ion temperature, high-power NBI (neutral beam injection) heating of 9 MW has realized a central ion temperature of 5 keV with neon injection. By introducing neon gas, the NBI absorption power was increased in low-density plasmas and the direct ion heating power was much enhanced with a reduced number of ions, compared with hydrogen plasmas.

1 October 1982 in Nuclear Fusion
Verified
Journal Article
Closed access
PDF file
TWT. Watari
T. Watari
KAK Adati
K Adati
TAT Aoki
T Aoki
SHS. Hidekuma
S. Hidekuma
KHK. Hattori
K. Hattori
MSM. Sugawara
M. Sugawara
Experimental data for ion cyclotron resonance heating in the RFC-XX machine in IPP-Nagoya are presented. The achieved ion temperature is as high as 100 eV at n = 1013 cm−3 and 1 keV at n = 1012 cm−3. The ion energy confinement becomes worse by the application of a longer pulse, which is found to be due to the enhanced charge-exchange loss and/or electron drag. Axially and azimuthally arrayed antennas are used in the heating, and the importance of the phasing is demonstrated. A simple model of the multiple-antenna problem is also given and used to interpret the experimental data.