Zhaoning Gu

Zhaoning Gu

Auto-generated profile, based on publicly available information

Zhaoning Gu

Key Laboratory of Underwater Acoustic Signal Processing, Ministry of Education, Southeast University, Nanjing, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2022 in IEEE Signal Processing Letters
Verified
Journal Article
Closed access
ZGZhaoning Gu
Zhaoning Gu
SFShiliang Fang
Shiliang Fang
We herein investigate the joint estimation of range and Doppler based on multipulse processing of composite hyperbolic frequency-modulated (HFM) waveforms. The composite HFM waveform solves the range bias problem in the HFM waveform by using the mapping relationship between the radial velocity and the peak-to-peak interval in the outputs of matched filters. However, the result may be inaccurate in the presence of multiple false peaks. In this letter, we fit matched filter outputs into a hidden Markov model by utilizing the kinetic model of the target. We can subsequently solve the peak-pair selection problem and perform the joint range-Doppler estimation by using the Viterbi algorithm. The proposed method, by multipulse processing, lowers the signal-to-noise ratio (SNR) requirement, and exact detection of the target in each return pulse is no longer necessary. We prove the effectiveness of the proposed method via numerical simulations, and the simulation results demonstrate that this method outperforms existing methods in low SNR environments.

20 February 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
WCWenjing Cao
Wenjing Cao
SFShiliang Fang
Shiliang Fang
ZGZhaoning Gu
Zhaoning Gu
MFMiao Feng
Miao Feng
HCHongli Cao
Hongli Cao
We propose a backscattering compensation based procedure to enhance the performance of multibeam echosounder systems (MBESs). High resolution in a wide field of view is the main benefit of MBESs, and this property makes them increasingly important for measuring scattering in water body. The performance of these systems is vulnerable to the anisotropic characteristics of scatterers, and thus, the results provided by MBESs can be inaccurate. To enhance the performance of MBESs, we compensate for the echo data on the basis of backscattering strength. The compensation considers the reflected sound energy by introducing interlayer coefficients calculated from the amounts of energy that penetrate into and are reflected from each layer. To demonstrate the effectiveness of the proposed method, we perform numerical simulations with randomly positioned scatters having anisotropic properties. Furthermore, anechoic pool experiments are conducted using bubbles generated by air compressors and propellers. The after-compensation results reveal richer details, thereby confirming the effectiveness of the proposed method.

24 August 2024 in Applied Acoustics
Verified
Journal Article
Closed access
MFMiao Feng
Miao Feng
SFShiliang Fang
Shiliang Fang
CZChuanqi Zhu
Chuanqi Zhu
LALiang An
Liang An
ZGZhaoning Gu
Zhaoning Gu
HCHongli Cao
Hongli Cao

25 July 2023 in Digital Signal Processing
Verified
Journal Article
Closed access
ZGZhaoning Gu
Zhaoning Gu
CZChuanqi Zhu
Chuanqi Zhu
SFShiliang Fang
Shiliang Fang

18 March 2026 in IEEE Transactions on Ultrasonics
Verified
Journal Article
Closed access
ZGZhaoning Gu
Zhaoning Gu
TXTianqi Xu
Tianqi Xu
YYYaoheng Yang
Yaoheng Yang
DYDezhuang Ye
Dezhuang Ye
HCHong Chen
Hong Chen
Sonogenetics, which utilizes ultrasound to modulate the activity of neurons expressing ultrasound-sensitive actuators, has emerged as a promising approach for implant-free, cell-type-specific neuromodulation. However, wearable transcranial focused ultrasound (tFUS) devices are needed to enable sonogenetic neuromodulation in freely moving mice, thereby facilitating the study of naturalistic behavioral responses with minimal physical constraints. To address this need, we present a fully validated protocol for the design, fabrication, and characterization of a wearable tFUS device. Our protocol details the selection of piezoelectric material, transducer fabrication and calibration, and installation of the device on the mouse head. We also provide a detailed protocol for using this tFUS device for performing sonogenetics in freely moving mice. The device’s efficacy in sonogenetic neuromodulation has been demonstrated in our previously published studies. The device can be used in a broad range of applications, including ultrasound neuromodulation (without genetics). All design files and accompanying software are freely available as open-source resources. This protocol is intended to lower the barrier to entry and facilitate the broader adoption of tFUS techniques in neuroscience research.