1 December 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
Real-time and accurate supervision of contamination conditions of composite insulators can effectively prevent the occurrence of pollution flashover accidents and ensure stable operation of the power system. In this article, a refined and controllable artificial contamination experiment is carried out, in which a total of 60 types of pollutants (12 contamination conditions) are formed by combining 20 types of equivalent salt deposit densities (ESDDs) at four contamination levels and three types nonsoluble deposit densities (NSDDs)/ESDD ratios to pollute composite insulators. Hyperspectral imaging technology is also introduced to extract the spectral data of polluted insulators, and the changing pattern of spectral curves under different pollution conditions is studied. Then, the spectral curve is preprocessed by black-and-white correction, standard normal variate (SNV), and detrending correction, and the preprocessed data are analyzed for band correlation. According to the variation pattern of the spectral curve and the band correlation characteristics, the full set of bands is divided into red, other visible, and near-infrared regions for principal component transformation respectively. Compared with the traditional principal component transformation, the former can reduce the calculation amount by 66%. Finally, to solve the problem of insufficiently labeled samples in practical engineering, a semi-supervised ladder network is used to realize pixel-level evaluation of insulator contamination conditions, and evaluation results are visualized. Research results show the pixel-level evaluation method can accurately evaluate contamination conditions of different areas on the surface of composite insulators. A semi-supervised model can guarantee the accuracy of classification results when there are few labeled samples. When the supervision rate is 10%, the classification accuracy of a semi-supervised model for contamination grade, NSDD/ESDD ratio, and contamination condition is higher than 95%, while that of a supervised model is lower than 90%.
25 December 2023 in IEEE Transactions on Dielectrics and Electrical Insulation
Accurate and real-time monitoring of the surface contamination status of insulators is of great significance for preventing pollution flashover accidents and maintaining system safety. This article introduces hyperspectral imaging technology to detect the contamination status of composite insulators. To address the impact of different outdoor lighting conditions on the detection of composite insulator contamination status, a composite insulator contamination status evaluation model is established based on the hyperspectral data collected indoors. Then, gradient spectral angle matching method is used to extract insulator images from the hyperspectral images collected under different outdoor lighting conditions, And the insulator image is segmented into multiple super-pixel regions using the energy driven sampling method. The super-pixel average spectral data was used instead of the pixel spectral data, and the contamination state was evaluated after the series processing of the two model transfer methods of correlation alignment method and piecewise direct standardization. The results show that the use of super-pixel segmentation method reduces the amount of data to be measured by 98% while ensuring the visualization of insulator pollution distribution, and the model transfer method improves the classification accuracy of the model from 50% to 90%, effectively reducing the impact of changes in lighting conditions on hyperspectral detection.
19 March 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Composite insulators are extensively employed in transmission lines. Investigating the impact of shed configuration on the contamination properties of insulators can offer scientific theoretical guidance for the selection of composite insulators. This paper integrates a semi-empirical mathematical expression, derived from experiments, describing the collision rebound movement between micrometer-sized particles and electrical silicone rubber with flow field simulation. A contamination deposition model for composite insulators is thus established, allowing for the extraction of comprehensive contamination information. Simultaneously, the accuracy of the model is verified by the wind tunnel comparative contamination tests, wherein the difference between the ratio of NSDD for different umbrella composite insulators obtained from experimentation and simulation calculations is less than 23%. And the influence of shed configuration on the contamination properties of composite insulators is explored. The results indicate that there is local particle retention zone on the surface of composite insulators. Under the condition of consistent umbrella parameters, composite insulators with one large, one small, one medium, and one small shed shape exhibit the best anti-pollution performance, and the greater the wind speed, the more obvious the influence of shed configuration. The research results of this paper have reference value for the selection of composite insulators for transmission lines.