Roberto Maffulli

Roberto Maffulli

Auto-generated profile, based on publicly available information

Roberto Maffulli

Department of Engineering Science, University of Oxford, Oxford OX1 3PJ, UK

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2014 in Journal of Propulsion and Power
Verified
Journal Article
Closed access
RMR. Maffulli
R. Maffulli
LHL. He
L. He
For external convective heat transfer, a common assumption based on the conventional wisdom is that aerodynamics determines the heat transfer coefficient without being affected by wall temperature. In this paper, a systematic computational study has been carried out on the effects of the wall thermal boundary condition on the external heat transfer coefficient for a two-dimensional nozzle guide vane section. Heat transfer coefficients are worked out first in a typical uncoupled manner with specified wall temperatures. As an alternative verification of the findings, further computations are also made using the coupled solid–fluid conjugate heat transfer mode of the solver. The present results show a strong dependence of heat transfer coefficient on wall temperature, in a locally varying manner, which cannot be corrected by using the existing correlations based on a global correction. A detailed examination of the boundary layer highlights the impact of upstream cooling history on the local heat transfer co...

19 April 2017 in Journal of Thermal Science and Engineering Applications
Verified
Journal Article
Closed access
PDF file
RMRoberto Maffulli
Roberto Maffulli
LHLi He
Li He
The present work is aimed to examine how the heat transfer coefficient (HTC) and main three-dimensional (3D) passage aerodynamic features may be affected by a nonadiabatic wall temperature condition. A systematic computational study has been first carried out for a 3D nozzle guide vane (NGV) passage. The impacts of wall temperature on the secondary flows, trailing edge shock waves, and the passage flow capacity are discussed, underlining the connection and interactions between the wall temperature and the external aerodynamics of the 3D passage. The local discrepancies in HTC in these 3D flow regions can be as high as 30–40% when comparing low and high temperature ratio cases. The effort is then directed to a new three-point nonlinear correction method. The benefit of the three-point method in reducing errors in HTC is clearly demonstrated. A further study illustrates that the new method also offers much enhanced robustness in the wall heat flux scaling, particularly relevant when the wall thermal condition is also shown to influence the laminar–turbulent transition exhibited by two well-established transition models adopted in the present work.

28 August 2018 in Journal of Turbomachinery
Verified
Journal Article
Closed access
PDF file
RMR. Maffulli
R. Maffulli
LHL. He
L. He
PSP. Stein
P. Stein
GMG. Marinescu
G. Marinescu

3 June 2013
Verified
Conference Paper
Closed access
PDF file
RMRoberto Maffulli
Roberto Maffulli
LHLi He
Li He
Developments of High Pressure Turbine (HPT) blades and vanes are particularly affected by the accuracy and consistency in heat transfer prediction techniques. The conventional wisdom in heat transfer analysis considers that aerodynamics fully determines Heat Transfer Coefficient (HTC) distribution along the blade surface, so that wall temperature should have no influence on HTC. The effect of the wall temperature on the heat transfer coefficient has been rarely studied, although there have been some rather scattered correlations regarding the influence of the wall-inflow temperature ratio on HTC, largely based on simple geometry configurations. There seems to be a need to answer two related questions: a) to what extent the conventional wisdom is valid, in particular for a transonic HPT blading? b) what is a consistent way by which the HTC should be worked out in CFD (as well as in experiment)? In this paper, computational analyses are carried out on the effects of wall thermal boundary condition on external HTC for a 2D Nozzle Guide Vane (NGV) profile. The study is performed by using Fluent® commercial Reynolds-Averaged Navier Stokes Equations solver. Further computations are also made using a coupled solid-fluid Conjugate Heat Transfer (CHT) method with an internally cooled blade. The present results show a strong dependence of HTC on wall temperature, far above that predicted by using the existing correlations, highlighting the importance of upstream boundary layer history on the HTC distribution. Influence of the wall temperature on the trailing edge shock position has been also observed. Based on the results found, a new method is proposed, allowing to model the HTC dependence on wall temperature with much improved accuracy as demonstrated.

5 February 2020 in Journal of Engineering for Gas Turbines and Power
Verified
Journal Article
Closed access
PDF file
RMRoberto Maffulli
Roberto Maffulli
GMGabriel Marinescu
Gabriel Marinescu
LHL. He
L. He
Accurate prediction of unsteady thermal loads is of paramount importance in several engineering disciplines and applications. Performing time-accurate unsteady conjugate heat transfer (CHT) simulations presents considerable challenges due to the markedly different time scales between the solid and fluid domains. Two methods have been recently proposed, aimed at addressing this issue: multiscale modeling (MSM) and equalized time-scales (ET). The former is based on the separation of the disparate short and long temporal scales of the solution and subsequent averaging of the flow/energy equations. In the latter, the equalization of the time scales is achieved through manipulation of the solid's thermal properties. Both methods are very appealing due to the possibility of being easily implemented on an existing solver. It becomes, thus, relevant to assess their performance and/or limitations. This paper work presents a comparative study of the two methods for the prediction of transient thermal load, first using a simplified case of a solid body with uniform temperature, then through the investigation of the prewarming phase of a steam turbine. Both methods are then compared against a reference baseline fully coupled (FC) CHT solution. The results show how the MSM allows greater accuracy and robustness with considerable saving in computational cost with respect to the baseline solution.

16 June 2014
Verified
Conference Paper
Closed access
PDF file
RMR. Maffulli
R. Maffulli
LHL. He
L. He
The dependency of convective heat transfer coefficient (HTC) on wall temperature has been recognized in some previous works but existing corrections are confined to either empirically based correlations or based on a boundary layer approach. A recent study by the present authors on a 2D configuration highlights upstream flow history has a strong impact on HTC for a non-adiabatic blade surface, and such an effect cannot be adequately corrected by the use of existing empirical correlations. A boundary layer based approach may be used in a 2D case for the correction as attempted previously. However, it is strongly argued that a boundary layer based method would become very difficult, if not impossible, to apply for complex 3D flows as those in endwall and secondary flow regions of a turbine blade passage. The present work is aimed to examine how the HTC and main 3D passage aerodynamic features of interest may be affected by the wall temperature condition. A systematic computational study has been firstly carried out for a 3D NGV passage. The impacts of wall temperature on the secondary flows, trailing edge shock waves and the passage flow capacity are discussed, underlining the connection and interactions between the wall temperature and the external aerodynamics of the 3D passage. The local errors in HTC in these 3D flow regions can be as high as 30–40% if the wall temperature dependence is not corrected. The effort is then directed to a new 3-point non-linear correction method. The benefit of the 3-point method in reducing errors in HTC is clearly demonstrated. A further study illustrates that the new method also offers much enhanced robustness in the HTC procedure, particularly relevant when the wall thermal condition is shown to influence the laminar-turbulent transition as exhibited by two well-established transition models adopted in the present work.