Daniel F. Leotta

Daniel F. Leotta

Auto-generated profile, based on publicly available information

Daniel F. Leotta

Applied Physics Laboratory, Center for Industrial and Medical Ultrasound, University of Washington, Seattle, WA, USA

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2010 in Cardiovascular Ultrasound
Verified
Journal Article
Open access
PDF file
KBKirk W Beach
Kirk W Beach
RBRobert O Bergelin
Robert O Bergelin
DLDaniel F Leotta
Daniel F Leotta
JPJean F Primozich
Jean F Primozich
PSP Max Sevareid
P Max Sevareid
RZR Eugene Zierler
R Eugene Zierler
Serial monitoring of patients participating in clinical trials of carotid artery therapy requires noninvasive precision methods that are inexpensive, safe and widely available. Noninvasive ultrasonic duplex Doppler velocimetry provides a precision method that can be used for recruitment qualification, pre-treatment classification and post treatment surveillance for remodeling and restenosis. The University of Washington Ultrasound Reading Center (UWURC) provides a uniform examination protocol and interpretation of duplex Doppler velocity measurements.

15 December 2024 in Journal of Oral Biology and Craniofacial Research
Verified
Journal Article
Open access
DSDoris H. Rosero Salazar
Doris H. Rosero Salazar
RGRiana Grewal
Riana Grewal
AVAnuj Vimawala
Anuj Vimawala
DLDaniel F. Leotta
Daniel F. Leotta
SLSwati R. Levendovszky
Swati R. Levendovszky
ZLZi-Jun Liu
Zi-Jun Liu
To evaluate the pharyngeal airway dimensions and regional pharyngeal adipose distribution in the young adult minipig model. Eight 7-8-months-old Yucatan minipigs, half male and female, were sedated and placed prone to scan the pharyngeal region. Magnetic resonance imaging (MRI) was performed using dynamic turbo-field echo (TFE)-sequence with respiratory gating and adipose-weighted sequence. Respiratory airflow velocity, pressure, and volume were also recorded. The sizes of velopharyngeal and oropharyngeal airway, and retroglossal areas were measured coronally during inspiration and expiration. The airway volumes from the nasal cavity to the retroglossal space were segmented, reconstructed, and evaluated in sagittal views. The adipose distribution in the tongue base, soft palate, pharyngeal wall, tongue body, and masseter muscle (reference) were segmented and measured in sagittal and coronal planes. The velopharyngeal and oropharyngeal areas were larger in inspiration than in expiration. These areas were also larger than that in the retroglossal space (p < 0.05). The nasal cavity showed a larger volume than that of the pharyngeal regions (p < 0.05). The adipose distribution was larger in the posterior region of the tongue base and anterior soft palate, both larger than the masseter muscle (p < 0.05). The larger oropharyngeal dimensions and increased adipose distribution in the tongue base contribute to the functional morphology of the pharyngeal airway in the healthy minipig. These data provide the baseline for further analysis in enlarged and reduced tongue base minipig models.

1 August 2018 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
DLDaniel F. Leotta
Daniel F. Leotta
RZR. Eugene Zierler
R. Eugene Zierler
KSKurt Sansom
Kurt Sansom
AAAlberto Aliseda
Alberto Aliseda
MAMark D. Anderson
Mark D. Anderson
FSFlorence H. Sheehan
Florence H. Sheehan

23 June 2019 in Vascular and Endovascular Surgery
Verified
Journal Article
Closed access
PDF file
RZR. Eugene Zierler
R. Eugene Zierler
DLDaniel F. Leotta
Daniel F. Leotta
KSKurt Sansom
Kurt Sansom
AAAlberto Aliseda
Alberto Aliseda
MAMark D. Anderson
Mark D. Anderson
FSFlorence H. Sheehan
Florence H. Sheehan
We developed a duplex ultrasound simulator and used it to assess accuracy of volume flow measurements in dialysis access fistula (DAF) models. The simulator consists of a mannequin, computer, and mock transducer. Each case is built from a patient’s B-mode images that are used to create a 3-dimensional surface model of the DAF. Computational fluid dynamics is used to determine blood flow velocities based on model vessel geometry. The simulator displays real-time B-mode and color-flow images, and Doppler spectral waveforms are generated according to user-defined settings. Accuracy was assessed by scanning each case and measuring volume flow in the inflow artery and outflow vein for comparison with true volume flow values. Four examiners made 96 volume flow measurements on four DAF models. Measured volume flow deviated from the true value by 35 ± 36%. Mean absolute deviation from true volume flow was lower for arteries than veins (22 ± 19%, N = 48 vs. 58 ± 33%, N = 48, p < 0.0001). This finding is attributed to eccentricity of outflow veins which resulted in underestimating true cross-sectional area. Regression analysis indicated that error in measuring cross-sectional area was a predictor of error in volume flow measurement (β = 0.948, p < 0.001). Volume flow error was reduced from 35 ± 36% to 9 ± 8% (p < 0.000001) by calculating vessel area as an ellipse. Duplex volume flow measurements are based on a circular vessel shape. DAF inflow arteries are circular, but outflow veins can be elliptical. Simulation-based analysis showed that error in measuring volume flow is mainly due to assumption of a circular vessel.

7 December 2023 in PLOS ONE
Verified
Journal Article
Open access
PDF file
DLDaniel F Leotta
Daniel F Leotta
DLDaniel Ly
Daniel Ly
BGBishoy Galil
Bishoy Galil
JTJeff Thiel
Jeff Thiel
EWElliot Willis
Elliot Willis
ZLZi-Jun Liu
Zi-Jun Liu
Obesity is a common finding and a major pathogenetic factor in obstructive sleep apnea (OSA) in adults. To understand the mechanisms behind this, the present study investigated the tissue properties and respiratory kinematics of the tongue base and soft palate in the obese OSA minipig model. In 4 verified obese/OSA and 3 non-obese/non-OSA control minipigs, MRI fat-weighted images, ultrasound elastography (USE), and sleep video-fluoroscopy (SVF) were performed to quantify the fat composition, tissue stiffness, and respiratory kinematics of the tongue base and soft palate during sedated sleep. The results indicated that the fat composition gradually increased from the rostral to caudal tongue base, particularly in the posterior 1/3 of the tongue base, regardless of the presence of obesity and OSA. However, this trend was not seen in the soft palate and pharyngeal wall. The pharyngeal wall presented the highest fat composition as compared with the tongue base and soft palate. Overall, obese OSA minipigs showed stiffer tongue tissue than the controls, particularly in the rostral region of the tongue in obese Yucatan minipigs. The respiratory moving ranges of the soft palate were greater in both dorsal-ventral and rostral-caudal directions and during both respiratory and expiratory phases in OSA obese than control minipigs, and the largest moving ranges were seen in OSA obese Panepinto minipigs. The moving range of the tongue base was significantly smaller. These results suggest more fat infiltration in the caudal region of the tongue base regardless of the presence of obesity and/or OSA. The greater tissue stiffness of the tongue in obese OSA minipigs may result from altered neuromuscular drive.

1 May 1996 in Journal of the American Society of Echocardiography
Verified
Journal Article
Closed access
PDF file
MLMalcolm Legget
Malcolm Legget
RMRoy W. Martin
Roy W. Martin
FSFlorence H. Sheehan
Florence H. Sheehan
GBGerard Bashein
Gerard Bashein
EBEdward L. Bolson
Edward L. Bolson
COCatherine M. Otto
Catherine M. Otto