David Romero Romero

David Romero Romero

Auto-generated profile, based on publicly available information

David Romero Romero

Instituto Politécnico Nacional, Escuela Superior de Ingeniería Mecánica y Eléctrica, Av. Luis Enrique Erro s/n, Ciudad de México 07738, Mexico

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 June 2024 in Processes
Verified
Journal Article
Open access
PDF file
OHOctavio López Hernández
Octavio López Hernández
DRDavid Romero Romero
David Romero Romero
MBMohamed Badaoui
Mohamed Badaoui
In this article, we present a modification to the Economic Dispatch (ED) model that addresses the non-convex nature of the cost curves associated with a Combined Cycle Power Plant (CCPP). Incorporating a binary variable provides greater precision in solving the combinatorial problem in only one simulation and, most importantly, demonstrates cost minimization among the three different cost curve models for dispatching the CCPP. Our results highlight the importance of considering different demand scenarios based on a reference forecast for one day ahead. Therefore, piecewise modeling is more feasible for solving the non-convex problem, showing greater accuracy regarding the operational state of the CCPP and avoiding the cost overestimation that occurs with traditional models. Moreover, it allows the operators to manage costs better and optimize generation potential, ultimately showing economic benefits for the system operator.

18 July 2025 in Forecasting
Verified
Journal Article
Open access
PDF file
ILIvan Itai Bernal Lara
Ivan Itai Bernal Lara
RDRoberto Jair Lorenzo Diaz
Roberto Jair Lorenzo Diaz
MGMaría de los Ángeles Sánchez Galván
María de los Ángeles Sánchez Galván
JGJaime Robles Garcia
Jaime Robles Garcia
MBMohamed Badaoui
Mohamed Badaoui
RFRodolfo Alfonso Moreno Flores
Rodolfo Alfonso Moreno Flores
This paper focuses on electricity demand forecasting and its uncertainty representation using a hybrid machine learning (ML) model in the eastern control area of southeastern Mexico. In this case, different sources of uncertainty are integrated by applying the Bootstrap method, which adds the characteristics of stochastic noise, resulting in a hybrid probabilistic and ML model in the form of a time series. The proposed methodology addresses a function density probability, which is the generalized of extreme values obtained from the errors of the ML model; however, it is adaptable and independent and simulates the variability that may arise due to unforeseen events. Results indicate that for a five-day forecast using only demand data, the proposed model achieves a Mean Absolute Percentage Error (MAPE) of 4.358%; however, incorporating temperature increases the MAPE to 5.123% due to growing uncertainty. In contrast, a day-ahead forecast, including temperature, improves accuracy, reducing MAPE to 1.644%. The stochastic noise component enhances probabilistic modeling, yielding a MAPE of 3.042% with and 2.073% without temperature in five-day forecasts. Therefore, the proposed model proves useful for regions with high demand variability, such as southeastern Mexico, while maintaining accuracy over longer time horizons.

1 January 2018 in Computación y Sistemas
Verified
Journal Article
Closed access
PDF file
EMEmilio Ricardo Moo Medina
Emilio Ricardo Moo Medina
DRDavid Romero Romero
David Romero Romero
In this paper the methodology of an application of a type-2 fuzzy logic controller for the speed control of a direct current machine subject to a stochastic and deterministic large signal is presented. A type-2 PI fuzzy logic controller using the Enhanced Karnick-Mendel algorithm (EKM) is proposed. This has a better runtime on the conventional Karnick-Mendel algorithm (KM). The nonlinear model of a 5 HP separately excited DC Motor including an armature voltage limiter is used. A 100% increment in the load torque is applied. This is a braking torque. This paper is a continuation of the research presented in [11]. Where, a type-2 PI fuzzy logic controller using a KM for the speed control of DC motor subject to a small disturbance in load and speed reference is analyzed. The type-2 PI controller is tuned based on a type-1 PI controller. The performance of both controllers is compared. The quantitative performance of both controllers is measured in terms of integral square error (ISE), integral absolute error (IAE) and integral time absolute error (ITAE). Tests show the advantage of the type-2 PI fuzzy controller when the motor load is subject to a stochastic and deterministic large disturbance. This is explained by the better handling of uncertainty and nonlinear behavior of type-2 PI. The robustness, in the results of both fuzzy controllers, presents stability in nonlinear sceneries when exposed to stochastic and deterministic large signals.

17 September 2024 in Systems
Verified
Journal Article
Open access
PDF file
MGMaría de los Ángeles Sánchez Galván
María de los Ángeles Sánchez Galván
JGJaime Robles Garcia
Jaime Robles Garcia
DRDavid Romero Romero
David Romero Romero
MBMohamed Badaoui
Mohamed Badaoui
This paper evaluates the impact of congestion on transmission lines when the operation cost is minimized using economic dispatch (ED), comparing the results obtained with the Nash–Cournot Equilibrium (NCE). A methodology is developed for the optimal power flow solution through the NCE, considering the network topology (upper and lower generation limits, upper and lower limits of the transmission lines, and power balance) for a nine-node system without and considering two bilateral power transactions. The results show that the operation cost is higher when the NCE is implemented than ED. However, the problem of congestion in the transmission lines is reduced due to the equilibrium obtained in the power dispatch against minimizing the operation cost in the dispatch; the transmission lines with the most significant participation tend to become congested when additional bilateral transactions occur. Finally, the above is verified by obtaining the mean and median of the transmission line percentages used in the two simulations.

28 March 2025 in Revista Iberoamericana de Automática e Informática Industrial
Verified
Journal Article
Open access
PDF file
JDJacob Díaz-Lavariega
Jacob Díaz-Lavariega
DRDavid Romero-Romero
David Romero-Romero
El sistema de excitación (SE) del generador síncrono tiene como función principal la regulación de voltaje terminal, y cuando es necesario se adiciona un estabilizador de potencia (ESP), para amortiguar oscilaciones de baja frecuencia (OSBF). La sintonización del ESP se realiza en un punto de operación cuando aparecen oscilaciones electromecánicas de baja frecuencia. En este trabajo se presenta un control adaptable entrenado en línea usando un agente inteligente basado en la teoría de resonancia adaptable para mejorar el desempeño del sistema de excitación en la regulación de voltaje y, adicionalmente, amortiguar las oscilaciones interplanta del sistema de potencia, e igualmente, aumentar el límite de transferencia en la línea de interconexión del sistema de potencia al mismo tiempo. El nuevo sistema de excitación se prueba en un sistema de dos áreas que presenta oscilaciones interárea e interplanta, comparándose con un sistema de excitación convencional IEEE ST1 A. El sistema desarrollado muestra que no esnecesario adicionar un ESP al control propuesto para amortiguar las OSBF satisfactoriamente.