Mariam Andersson

Mariam Andersson

Auto-generated profile, based on publicly available information

Mariam Andersson

Danish Research Centre for Magnetic Resonance, Center for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Amager and Hvidovre

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2020 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
MAMariam Andersson
Mariam Andersson
HKHans Martin Kjer
Hans Martin Kjer
JRJonathan Rafael-Patino
Jonathan Rafael-Patino
APAlexandra Pacureanu
Alexandra Pacureanu
BPBente Pakkenberg
Bente Pakkenberg
TDTim B. Dyrby
Tim B. Dyrby
Axonal conduction velocity, which ensures efficient function of the brain network, is related to axon diameter. Noninvasive, in vivo axon diameter estimates can be made with diffusion magnetic resonance imaging, but the technique requires three-dimensional (3D) validation. Here, high-resolution, 3D synchrotron X-ray nano-holotomography images of white matter samples from the corpus callosum of a monkey brain reveal that blood vessels, cells, and vacuoles affect axonal diameter and trajectory. Within single axons, we find that the variation in diameter and conduction velocity correlates with the mean diameter, contesting the value of precise diameter determination in larger axons. These complex 3D axon morphologies drive previously reported 2D trends in axon diameter and g-ratio. Furthermore, we find that these morphologies bias the estimates of axon diameter with diffusion magnetic resonance imaging and, ultimately, impact the investigation and formulation of the axon structure–function relationship. Significance Axons, the brain’s communication cables, have been described as cylinders since their discovery in 1860. Their structure is linked to how fast they conduct signals and is thus indicative of brain health and function. Here, we demonstrate an interplay between the micromorphology of axons and other extra-axonal structures, showing that axons are noncylindrical and exhibit environment-dependent diameter and trajectory variations. The nonspecificity in diameter, and thus conduction velocity, challenges the current knowledge of how axons communicate signals. Diffusion magnetic resonance imaging can be used to measure axon diameter in the living brain in order to explore the brain network and detect potential biomarkers of disease, but we show here that the observed complex morphologies of axons bias these measurements.

1 March 2022 in NeuroImage
Verified
Journal Article
Open access
MAMariam Andersson
Mariam Andersson
MPMarco Pizzolato
Marco Pizzolato
HKHans Martin Kjer
Hans Martin Kjer
KSKatrine Forum Skodborg
Katrine Forum Skodborg
HLHenrik Lundell
Henrik Lundell
TDTim B. Dyrby
Tim B. Dyrby
Noninvasive estimation of axon diameter with diffusion MRI holds the potential to investigate the dynamic properties of the brain network and pathology of neurodegenerative diseases. Recent studies use powder averaging to account for complex white matter architectures, but these have not been validated for real axonal geometries from regions that contain fibre crossings. Here, we present 120-304μm long segmented axons from X-ray nano-holotomography volumes of a splenium and crossing fibre region of a vervet monkey brain. We show that the axons in the complex crossing fibre region, which contains callosal, association, and corticospinal connections, exhibit a wider diameter distribution than those of the splenium region. To accurately estimate the axon diameter in these regions, therefore, sensitivity to a wide range of diameters is required. We demonstrate how the q-value, b-value, signal-to-noise ratio and the assumed intra-axonal parallel diffusivity influence the range of measurable diameters with powder average approaches. Furthermore, we show how Gaussian distributed noise results in a wider range of measurable diameter at high b-values than Rician distributed noise, even at high signal-to-noise ratios of 100. The number of gradient directions is also shown to impose a lower bound on measurable diameter. Our results indicate that axon diameter estimation can be performed with only few b-shells, and that additional shells do not improve the accuracy of the estimate. For strong gradients available on human Connectom and preclinical scanners, Monte Carlo simulations of diffusion confirm that powder averaging techniques succeed in providing accurate estimates of axon diameter across a range of diameters, sequence parameters and diffusion times, even in complex white matter architectures. At relatively low b-values, the diameter estimate becomes sensitive to axonal microdispersion and the intra-axonal parallel diffusivity shows time dependency at both in vivo and ex vivo intrinsic diffusivities.

16 February 2023 in Medical Image Analysis
Verified
Journal Article
Open access
MPMarco Pizzolato
Marco Pizzolato
Erick Jorge Canales-RodríguezErick Jorge Canales-Rodríguez
Erick Jorge Canales-Rodríguez
MAMariam Andersson
Mariam Andersson
TDTim B. Dyrby
Tim B. Dyrby
We enable the estimation of the per-axon axial diffusivity from single encoding, strongly diffusion-weighted, pulsed gradient spin echo data. Additionally, we improve the estimation of the per-axon radial diffusivity compared to estimates based on spherical averaging. The use of strong diffusion weightings in magnetic resonance imaging (MRI) allows to approximate the signal in white matter as the sum of the contributions from only axons. At the same time, spherical averaging leads to a major simplification of the modeling by removing the need to explicitly account for the unknown distribution of axonal orientations. However, the spherically averaged signal acquired at strong diffusion weightings is not sensitive to the axial diffusivity, which cannot therefore be estimated although needed for modeling axons - especially in the context of multi-compartmental modeling. We introduce a new general method for the estimation of both the axial and radial axonal diffusivities at strong diffusion weightings based on kernel zonal modeling. The method could lead to estimates that are free from partial volume bias with gray matter or other isotropic compartments. The method is tested on publicly available data from the MGH Adult Diffusion Human Connectome project. We report reference values of axonal diffusivities based on 34 subjects, and derive estimates of axonal radii from only two shells. The estimation problem is also addressed from the angle of the required data preprocessing, the presence of biases related to modeling assumptions, current limitations, and future possibilities.

1 February 2022 in Magnetic Resonance Imaging
Verified
Journal Article
Open access
MPMarco Pizzolato
Marco Pizzolato
MAMariam Andersson
Mariam Andersson
Erick Jorge Canales-RodríguezErick Jorge Canales-Rodríguez
Erick Jorge Canales-Rodríguez
JTJean-Philippe Thiran
Jean-Philippe Thiran
TDTim B. Dyrby
Tim B. Dyrby
In magnetic resonance imaging, the application of a strong diffusion weighting suppresses the signal contributions from the less diffusion-restricted constituents of the brain's white matter, thus enabling the estimation of the transverse relaxation time T2 that arises from the more diffusion-restricted constituents such as the axons. However, the presence of cell nuclei and vacuoles can confound the estimation of the axonal T2, as diffusion within those structures is also restricted, causing the corresponding signal to survive the strong diffusion weighting. We devise an estimator of the axonal T2 based on the directional spherical variance of the strongly diffusion-weighted signal. The spherical variance T2 estimates are insensitive to the presence of isotropic contributions to the signal like those provided by cell nuclei and vacuoles. We show that with a strong diffusion weighting these estimates differ from those obtained using the directional spherical mean of the signal which contains both axonal and isotropically-restricted contributions. Our findings hint at the presence of an MRI-visible isotropically-restricted contribution to the signal in the white matter ex vivo fixed tissue (monkey) at 7T, and do not allow us to discard such a possibility also for in vivo human data collected with a clinical 3T system.

20 October 2023 in bioRxiv
Verified
Preprint
Open access
PDF file
CSChristian Stald Skoven
Christian Stald Skoven
MAMariam Andersson
Mariam Andersson
MPMarco Pizzolato
Marco Pizzolato
HSHartwig Roman Siebner
Hartwig Roman Siebner
TDTim B. Dyrby
Tim B. Dyrby
The structure-function relationship of nerve fibers describes an empirically determined linear relationship between axon diameter, myelin thickness (i.e., g-ratio), and conduction velocity. We investigated the structure-function relationship with different modalities in axons projecting through the corpus callosum of the rodent brain. We measured transcallosal conduction times using optogenetically evoked local field potentials (LFP) and estimated conduction velocity after measuring the callosal length with diffusion magnetic resonance imaging (dMRI) based tractography. Tractography followed the same projection as the fluorescently labeled axons in the corpus callosum. In the same animal, axon diameters were quantified using transmission electron microscopy (TEM) and dMRI. Axon distributions of TEM indicated a bimodal population, where the larger axons shrink more than the smaller ones, when comparing the modes with cryo-TEM. When applying shrinkage-correction to axon diameters from TEM of dehydrated tissue, they were better aligned with estimates from dMRI obtained in the same animal. Measured LFPs predicted axon diameters that agree with the primary mode of the axon distribution, whereas the large axons estimated by dMRI predicted latencies too short to be measured by LFPs. Different modalities show different degrees of variations, being low between animals, suggesting that the variation is methodologically dominated - not anatomically. Our results show that modalities have different sensitivity profiles to the whole axon diameter distribution. Therefore, caution must be taken when interpreting a method’s prediction of a metric, as it may not represent the full but only a sub-part of the structure-function relationship of an axonal projection. Significance Statement: We acquire both functional and structural metrics, namely conduction velocity, pathway length, axon diameter, and g-ratio in the same cohort of animals. The transcallosal conduction time was obtained from electrophysiological measurements after contralateral optogenetic stimulation in the rat motor cortex. Cryo-fixation of the tissue reveals different shrinkages for different sub-populations in the diameter distribution. Measured latencies correspond to the small axonal subpopulation with diameters extending up to the mode of the distribution obtained with electron microscopy. Diffusion-MRI primarily appears sensitive to the larger axons, obtained with histology, after correcting for diameter weighting and shrinkage. Different modalities can have very different sensitivities to the structure-function relationship of an axonal projection which must be accounted for in the interpretation.

22 December 2025 in Imaging Neuroscience
Verified
Journal Article
Open access
CSChristian Stald Skoven
Christian Stald Skoven
MAMariam Andersson
Mariam Andersson
MTMiren Lur Barquin Torre
Miren Lur Barquin Torre
MPMarco Pizzolato
Marco Pizzolato
HSHartwig R. Siebner
Hartwig R. Siebner
TDTim B. Dyrby
Tim B. Dyrby
The structure-function relationship of myelinated nerve fibers (Waxman & Bennett, 1972) links axon diameter and myelin thickness, commonly expressed as the g-ratio, to conduction velocity via saltatory mechanisms. Here, we investigated this relationship in the transcallosal motor pathway of the rat brain by combining functional and structural metrics in the same animals. Transcallosal conduction times (TCTs) were measured using local field potentials (LFPs) evoked by optogenetic stimulation of excitatory neurons in the motor cortex. Conduction velocity estimates were obtained by combining TCTs with transcallosal tract lengths derived from diffusion MRI (dMRI)-based tractography. Fluorescent labeling of the viral optogenetic construct verified the tractography trajectories. In parallel, axon diameter and g-ratio were quantified using both dMRI and transmission electron microscopy (TEM). To assess dehydration-induced tissue shrinkage associated with conventional TEM preparation (“Epon-TEM”), we also performed cryo-fixation followed by TEM (“Cryo-TEM”) in a separate group. This revealed diameter-dependent axonal shrinkage, yielding a correction factor of 37%. Shrinkage correction improved agreement between dMRI and Epon-TEM estimates, although dMRI remained biased toward larger axons. When translated via the structure-function relationship, TCTs corresponded to smaller axons near the mode of the TEM diameter distribution, while dMRI-based diameters predicted TCTs that were too short compared with the recorded LFP latencies. Altogether, our findings show that structural and functional metrics differ in their sensitivity profiles. Accounting for such modality-dependent sensitivities facilitates the investigation of structure-function relationships, advancing our understanding of how microstructure supports neural communication.