Minfei Qiang

Minfei Qiang

Auto-generated profile, based on publicly available information

Minfei Qiang

Department of Orthopedic Surgery, Zhongshan Hospital, Fudan University, Shanghai, China

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2018 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
CYChen Yanxi
Chen Yanxi
XJXiaoyang Jia
Xiaoyang Jia
MQMinfei Qiang
Minfei Qiang
KZKun Zhang
Kun Zhang
SCSong Chen
Song Chen
Background: This study aimed to determine the difference between computer-assisted virtual surgical technology and 3-dimensional (3D) printing technology in preoperative planning for proximal humeral fractures. Methods: Between February 2009 and October 2015, 131 patients with 3 and 4-part proximal humeral fractures were divided into 3 groups on the basis of the preoperative planning method: conventional (n = 53), virtual surgical (n = 46), and 3D printing (n = 32). Fracture characteristics and intraoperative realization of preoperative planning (reduction shape and implant choices) were evaluated. Postoperative functional outcomes were assessed using the American Shoulder and Elbow Surgeons, Constant-Murley, and Short Form-36 (SF-36) scoring systems and shoulder range of motion; postoperative radiographic outcomes were assessed with respect to the loss of the neck-shaft angle (NSA) and loss of humeral head height (HHH). Results: Excellent sensitivity, specificity, and accuracy for fracture characteristics were seen in all 3 groups. The correlations for NSA (p = 0.033) and HHH (p = 0.035) were higher in the virtual surgical group than in the 3D printing group. The lengths of the medial support screws in the actual choices were shorter than those in the preoperative plan for the 3D printing group, but a similar pattern was not seen in the virtual surgical group. Compared with the conventional method, the virtual surgical and 3D printing methods of preoperative planning resulted in shorter operative time, less blood loss, and fewer fluoroscopic images. The functional outcomes in both the 3D printing and virtual surgical groups were better than those in the conventional group. The virtual surgical method was faster than the 3D printing method, as suggested by a shorter time to surgery (2.5 compared with 4.6 days; p < 0.001), a shorter time for preoperative planning (30.4 compared with 262.4 minutes; p < 0.001), and a decreased duration of hospital stay (10.9 compared with 14.6 days; p < 0.001). Conclusions: The clinical outcomes in both the virtual surgical and 3D printing groups were better than those in the conventional group. However, computer-assisted virtual surgical technology is more convenient and efficient, considering the shorter time for preoperative planning. In addition, it has improved correlation with preoperative planning. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

1 January 2015 in Journal of Foot and Ankle Research
Verified
Journal Article
Open access
PDF file
CYChen Yanxi
Chen Yanxi
MQMinfei Qiang
Minfei Qiang
KZKun Zhang
Kun Zhang
HLHaobo Li
Haobo Li
HDHao Dai
Hao Dai
Background: Syndesmotic injury may be difficult to diagnose, and radiological evaluation is very important. The purpose of this study was to offer a series of reliable and repeatable normal tibiofibular syndesmosis parameters in diagnosing injuries of the syndesmosis.Methods: Multi‐detector computed tomography (MDCT) and radiographs of the distal tibiofibular syndesmosis in 484 cases were retrospectively reviewed. Relevant parameters included the tibiofibular clear space (TCS), the tibiofibular overlap (TFO), the depth of the incisura fibularis (IFD), and the height of the incisura fibularis (IFH), which were measured by novel three‐dimensional (3‐D) and two‐dimensional (2‐D) techniques. The distance between the measuring plane of the distal tibiofibular syndesmosis and the tibial plafond was measured. Intra‐ and inter‐rater reliability was assessed by intraclass correlation coefficient (ICC) and the root mean square standard deviation (RMS‐SD), to determine measurement precision. Sex differences of parameters were analyzed using analysis of covariance (ANCOVA) with body height as the covariate. Paired sample t‐testing was used to compare parameters in different image modalities, including radiography, and 2‐D and 3‐D CT.Results: The reliability of the 3‐D images measurement (ICC range, 0.907 to 0.972) was greater than that for the 2‐D axial images (ICC range, 0.895 to 0.927), and the AP view radiographs (ICC range, 0.742 to 0.838). The intra‐rater RMS‐SD of the 3‐D CT, 2‐D CT and radiographic measurements were less than 0.94 mm, 0.26 mm, and 2.87 mm, respectively. The measuring plane of the distal tibiofibular syndesmosis showed the sex difference, which was 12.1 mm proximal to the tibial plafond in the male group and 7.8 mm in the female group. In this plane, the parameters for tibiofibular syndesmosis were measured in different image modalities. All variables were significantly different between females and males (p < 0.05).Conclusions: 3‐D measurement technique could be helpful to identify the precise measurement planes for syndesmosis, which were not at the fixed level above the tibial plafond because of the sex difference. In this plane, reliable measurement results could be provided, in either 2‐D or 3‐D MDCT images.


15 July 2016 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
XJXiaoyang Jia
Xiaoyang Jia
CYChen Yanxi
Chen Yanxi
MQMinfei Qiang
Minfei Qiang
KZKun Zhang
Kun Zhang
HLHaobo Li
Haobo Li
YZYijie Zhang
Yijie Zhang
Accurate comprehension of the normal humeral morphology is crucial for anatomical reconstruction in shoulder arthroplasty. However, traditional morphological measurements for humerus were mainly based on cadaver and radiography. The purpose of this study was to provide a series of precise and repeatable parameters of the normal proximal humerus for arthroplasty, based on the three-dimensional (3-D) measurements. Radiographic and 3-D computed tomography (CT) measurements of the proximal humerus were performed in a sample of 120 consecutive adults. Sex differences, two image modalities differences, and correlations of the parameters were evaluated. Intra- and inter-observer reproducibility was evaluated using intraclass correlation coefficients (ICCs). In the male group, all parameters except the neck-shaft angle of humerus, based on 3-D CT images, were greater than those in the female group (P < 0.05). All variables were significantly different between two image modalities (P < 0.05). In 3-D CT measurement, all parameters expect neck-shaft angle had correlation with each other (P < 0.001), particularly between two diameters of the humeral head (r = 0.907). All parameters in the 3-D CT measurement had excellent reproducibility (ICC range, 0.878 to 0.936) that was higher than those in the radiographs (ICC range, 0.741 to 0.858). The present study suggested that 3-D CT was more reproducible than plain radiography in the assessment of morphology of the normal proximal humerus. Therefore, this reproducible modality could be utilized in the preoperative planning. Our data could serve as an effective guideline for humeral component selection and improve the design of shoulder prosthesis.

4 April 2020 in International Orthopaedics
Verified
Journal Article
Closed access
PDF file
XJXiaoyang Jia
Xiaoyang Jia
KZKun Zhang
Kun Zhang
MQMinfei Qiang
Minfei Qiang
CYChen Yanxi
Chen Yanxi

10 April 2019 in International Orthopaedics
Verified
Journal Article
Closed access
PDF file
MQMinfei Qiang
Minfei Qiang
KZKun Zhang
Kun Zhang
CYChen Yanxi
Chen Yanxi
XJXiaoyang Jia
Xiaoyang Jia
XWXiong Wang
Xiong Wang
SWShuguang Wang
Shuguang Wang