Future climate is expected to be warmer, more humid, and cloudier with more frequent extreme weather conditions. Current building design should consider these changes as they can significantly influence the function of buildings in the future. Here, we study common building envelope assembly subjected to different climatic scenarios. An experiment was set up to validate a numerical model, which is further applied to assess hygrothermal performance (heat and moisture transfer) of the building envelope subjected to different boundary conditions. The assessment is provided via Finnish mould growth model that identifies risk of biological growth through dynamic hygrothermal conditions. Finnish meteorological institute provides data that predicts the climate in 2030, 2050 and 2100. The humidity inside the building envelope is assumed to increase slightly in time, however, increased temperature in the future may cause more favorable conditions for mould growth, especially, if mould sensitive building materials are used. The hygrothermal assessment of building structures with consideration of climate change in structural design is a key factor to provide sustainable building designs. Numerical model was successfully validated with experiments providing data within tolerances of measurement equipment.
Buildings must remain climate-resilient over service lives of up to 100 years. The Nordic climate has warmed by over 2 °C since 1850 and is projected to experience further increases in temperature, precipitation, and summer solar radiation. These changes are expected to intensify hygrothermal risks and overheating in buildings. Although façade colour has been linked to summer cooling demand, its combined effects on hygrothermal performance, energy use, and indoor thermal conditions remain largely unexplored in Nordic climates. This study addresses this gap by examining three façade colours on a typical Finnish timber-frame house. Using validated WUFI and IDA ICE simulations calibrated with measurements, the study evaluates the effects of façade colour on hygrothermal performance, energy use, heating and cooling demands, and indoor thermal comfort under current and RCP8.5 2080 climate conditions. Façade colour was found to have the most pronounced effect on hygrothermal performance. Medium to dark façades with higher solar absorptivity (≥0.6) reduced mould risk (M=0.99) and improved the hygrothermal performance of external walls, whereas light-coloured façades (≤0.3) exhibited a clearly higher mould risk (M=2.16), particularly under the RCP8.5 2080. Dark façades increased peak wall temperatures, indicating higher thermal stress. In contrast, the projected future climate had a substantially greater impact on building energy performance than façade colour, which showed only minor effects on total energy use, heating and cooling demands. Impacts on thermal comfort were limited under current climate, although darker façades slightly increased overheating risk in future conditions.