Michael Reiter

Michael Reiter

Auto-generated profile, based on publicly available information

Michael Reiter

University of Applied Sciences Upper Austria Stelzhamerstraße 23 4600 Wels Austria

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2020 in Nondestructive Testing and Evaluation
Verified
Journal Article
Open access
SSSascha Senck
Sascha Senck
MHMichael Happl
Michael Happl
MRMichael Reiter
Michael Reiter
MSMichael Scheerer
Michael Scheerer
MKManuel Kendel
Manuel Kendel
JKJohann Kastner
Johann Kastner
Additive manufacturing (AM) unlocks novel industrial possibilities in relation to design optimisation for lightweight structures, e.g. in aerospace applications. However, the inherent geometric complexity of topology-optimised AM components represents a major challenge for conventional non-destructive testing (NDT) methods. Due to its flexibility and high throughput, industrial X-ray micro-computed tomography (XCT) is the most promising NDT method for AM. In this contribution, we investigate topology-optimised engine brackets that were manufactured from AlSi10 Mg using selective laser melting (SLM). We investigate the respective parts and in-process test coupons in a multiscale approach to be able to extract pore size distributions at different spatial resolutions between 105 and 1.25 µm isometric voxel size. At the lowest spatial resolutions, existing pores cannot be segmented. In contrast, decreasing voxel sizes leads to an increase in total porosity up to 1.53%. Defects like pores in load-carrying areas can profoundly influence the component´s mechanical performance; hence, extensive NDT investigations are mandatory to predict the effect of defects in aluminium AM components.

28 October 2010 in IEEE Transactions on Visualization and Computer Graphics
Verified
Journal Article
Closed access
AAArtem Amirkhanov
Artem Amirkhanov
CHChristoph Heinzl
Christoph Heinzl
MRMichael Reiter
Michael Reiter
EGEduard Gröller
Eduard Gröller
Industrial cone-beam X-Ray computed tomography (CT) systems often face problems due to artifacts caused by a bad placement of the specimen on the rotary plate. This paper presents a visual-analysis tool for CT systems, which provides a simulation-based preview and estimates artifacts and deviations of a specimen's placement using the corresponding 3D geometrical surface model as input. The presented tool identifies potentially good or bad placements of a specimen and regions of a specimen, which cause the major portion of artefacts. The tool can be used for a preliminary analysis of the specimen before CT scanning, in order to determine the optimal way of placing the object. The analysis includes: penetration lengths, placement stability and an investigation in Radon space. Novel visualization techniques are applied to the simulation data. A stability widget is presented for determining the placement parameters' robustness. The performance and the comparison of results provided by the tool compared with real world data is demonstrated using two specimens.

3 November 2018 in Journal of Nondestructive Evaluation
Verified
Journal Article
Open access
PDF file
CGChristian Gusenbauer
Christian Gusenbauer
MRMichael Reiter
Michael Reiter
BPBernhard Plank
Bernhard Plank
DSDietmar Salaberger
Dietmar Salaberger
SSSascha Senck
Sascha Senck
JKJohann Kastner
Johann Kastner
This paper presents multi-modal image data of different fibre reinforced polymer samples acquired with a desktop Talbot-Lau grating interferometer (TLGI) X-ray computed tomography (XCT) system and compare the results with images acquired using conventional absorption-based XCT. Two different fibre reinforced polymer samples are investigated: (i) a carbon fibre reinforced polymer (CFRP) featuring a copper mesh embedded near the surface for lightning conduction and (ii) a short glass fibre reinforced polymer (GFRP) sample. The primary goal is the non-destructive detection of internal defects such as pores and the quantification of porosity. TLGI provides three imaging modalities including attenuation contrast (AC) due to absorption, differential phase contrast (DPC) due to refraction and dark-field contrast (DFC) due to scattering. In the case of the CFRP sample, DPC is less prone to metal streak artefacts improving the detection of pores that are located close to metal components. In addition, results of a metal artefact reduction (MAR) method, based on sinogram inpainting and an image fusion concept for AC, DPC and DPC, are presented. In the case of the GFRP sample, DPC between glass fibres and matrix is lower compared to AC while DPC shows an increased contrast between pores and its matrix. Porosity for the CFRP sample is determined by applying an appropriate global thresholding technique while an additional background removal is necessary for the GFRP sample.

3 November 2011 in IEEE Transactions on Visualization and Computer Graphics
Verified
Journal Article
Closed access
AAArtem Amirkhanov
Artem Amirkhanov
CHChristoph Heinzl
Christoph Heinzl
MRMichael Reiter
Michael Reiter
JKJohann Kastner
Johann Kastner
EGEduard Groller
Eduard Groller
Multi-material components, which contain metal parts surrounded by plastic materials, are highly interesting for inspection using industrial 3D X-ray computed tomography (3DXCT). Examples of this application scenario are connectors or housings with metal inlays in the electronic or automotive industry. A major problem of this type of components is the presence of metal, which causes streaking artifacts and distorts the surrounding media in the reconstructed volume. Streaking artifacts and dark-band artifacts around metal components significantly influence the material characterization (especially for the plastic components). In specific cases these artifacts even prevent a further analysis. Due to the nature and the different characteristics of artifacts, the development of an efficient artifact-reduction technique in reconstruction-space is rather complicated. In this paper we present a projection-space pipeline for metal-artifacts reduction. The proposed technique first segments the metal in the spatial domain of the reconstructed volume in order to separate it from the other materials. Then metal parts are forward-projected on the set of projections in a way that metal-projection regions are treated as voids. Subsequently the voids, which are left by the removed metal, are interpolated in the 2D projections. Finally, the metal is inserted back into the reconstructed 3D volume during the fusion stage. We present a visual analysis tool, allowing for interactive parameter estimation of the metal segmentation. The results of the proposed artifact-reduction technique are demonstrated on a test part as well as on real world components. For these specimens we achieve a significant reduction of metal artifacts, allowing an enhanced material characterization.

12 December 2018 in Journal of Nondestructive Evaluation
Verified
Journal Article
Open access
PDF file
MRMichael Reiter
Michael Reiter
FOFabrício Borges de Oliveira
Fabrício Borges de Oliveira
MBMarkus Bartscher
Markus Bartscher
CGChristian Gusenbauer
Christian Gusenbauer
JKJohann Kastner
Johann Kastner
This paper presents a case study of two selected beam hardening correction methods and their effects on dimensional measurements of multi-material objects. The methods under test are empirical cupping correction (ECC) and empirical dual energy calibration (EDEC). These methods were originally developed for medical applications and their potential for the reduction of artefacts is typically only analysed based on grey value images. For testing and benchmarking of the mentioned methods for dimensional metrology, a dedicated multi-material reference standard—a multi-material hole cube—is used. This reference standard was originally developed for acceptance testing of CT systems. This paper shows a second application of this standard. The reference standard has been calibrated by tactile measurements to assess centre–centre distance errors as well as patch-based bidirectional length measurement errors on beam hardening corrected data and on uncorrected data. For the application of the method also to industrial multi-material scenarios, slight modifications of the ECC method are proposed. Practical aspects of both the ECC and the EDEC approaches as well as measurement results are analysed and discussed in detail. ECC was able to significantly improve dimensional measurements and was especially able to reduce extreme errors occurring in particular in multi-material scenarios by a factor of more than 4. EDEC, the dual-energy approach, reduced grey value inhomogeneities caused by artefacts even more. Its performance for dimensional measurements was however a little worse than ECC. EDEC data resulted in a slightly larger total range of residual measurement errors, mainly due to an elevated noise level.

1 June 2008 in Powder Diffraction
Verified
Journal Article
Closed access
PDF file
BCB. Chyba
B. Chyba
MMM. Mantler
M. Mantler
MRM. Reiter
M. Reiter
Results from Monte Carlo simulations of two-dimensional projections for a simple real sample (an aluminium cube with a cylindrical hole filled by air or steel) in a realistic experimental environment are presented. A meaningful comparison with measurements was therefore possible. Coherent and incoherent scattering as well as excitation of fluorescent radiation are accounted for; multiple sequences of these interactions are followed up to a selectable order. Such simulations are important aids to modern metrological applications of computed tomography where the dimensional accuracy of hidden or inaccessible components of work pieces is determined. The complex process requires a high level of optimization of the instrumental parameters for each sample type whereby the accurate simulation of the physical interactions between X-rays and the sample material is a supplement and alternative to time consuming measurements.