1 March 2024 in Physics of Fluids
Curvature plays a crucial role in evolving supersonic cooling film flow-field structures. Flow-field structural images were captured using nanotracer-based planar laser scattering,, and wall pressure values were obtained using experimentally validated numerical simulations. A supersonic cooling film is tangentially injected at the Mach number of Maj = 2.3 into a laminar boundary layer at a mainstream of Ma = 6. The supersonic cooling film inhibits mixing-layer instability on the convex curved wall (CV) and promotes it on the concave curved wall (CC). After increasing the total incoming pressure, the reduction ratio of static pressure (RSP) between the supersonic cooling film and the mainstream flow causes a delay in the position of the mixing-layer instability, smaller-scale vortex structures, and decreased flow velocity of the typical vortex structures on the CC and CV. The wall pressure increases for the CV and decreases for the CC, indicating that the supersonic cooling film suppresses the changes in wall pressure due to curvature. The supersonic cooling film suppresses the decrease in the impulses for bulk dilatation (Ip) due to convex curvature and the increase in Ip due to concave curvature. The growth rate of Ip on the CC increases from −15% to −8% and decreases on the CV from 31% to 12% in the bending impulse (IΦ) range of |IΦ| = 1.337–3.624 for a total inlet pressure of 0.5 MPa. Increasing the RSP could control the Ip values on curved surfaces more effectively. The results of this study can be applied to cooling the infrared optics window on hypersonic vehicles.
1 July 2025 in Physics of Fluids
During the flight of hypersonic aircraft, severe aerodynamic heating occurs at critical regions such as the nose and the leading edge of rudders, presenting significant challenges to the design of hypersonic vehicles. This paper systematically investigates the flow field characteristics and aerodynamic force/heat properties of the leading edge of a hypersonic aircraft's air rudder with active jet cooling, employing numerical simulations and experimental studies. The thermal protection mechanism of the multi-hole opposing jet at the rudder leading edge is explored by varying the position, spacing, and sweep angle of the jet holes. The thermal protection effectiveness under different jet total pressure ratios is also experimentally validated, providing critical data references for engineering applications. The results demonstrate that, under a constant jet total pressure ratio, a larger sweep angle enhances the cooling effectiveness of the jet, and the effective cooling length exhibits a quadratic relationship with the sweep angle. At a sweep angle of 60°, the jet hole position closer to the flat plate wall slightly enhances overall cooling performance but may intensify localized overheating upstream of the jet hole. Increasing the spacing between jet holes expands the effective cooling length for a constant position of the bottom jet hole while reducing the localized heat mitigation effect upstream of the holes. This study reveals that dual-hole configurations provide a cooling effect more than twice that of single-hole systems. It reveals that the cooling effect becomes more pronounced with higher total jet pressure ratios, but the efficiency ratio decreases.
1 August 2025 in Physics of Fluids
Seepage through microstructure on the surface, as a novel approach for boundary layer flow control, holds considerable promise for drag and thermal reduction in hypersonic vehicles. This paper presents an experimental study conducted in a Mach 6 hypersonic high-temperature wind tunnel, utilizing a cone with seepage through microstructure on the surface. The study employs schlieren, high-frequency fluctuating pressure measurement techniques, and infrared thermometry. It focuses on the influence of the amplitude-frequency characteristics of the second-mode waves within the hypersonic boundary layer on aerodynamic heating on the wall. According to the research, the following findings were observed: For smooth surfaces, the characteristic frequency of the second-mode wave decreases from 109 to 87 kHz along the flow direction. However, microstructures cause an average increase in the characteristic frequency by approximately 20 kHz, while seepage causes the characteristic frequency along the flow direction to change little. Under the same seepage flow rate, the amplitude of the second-mode waves within the boundary layer exhibits two peaks along the flow direction. When the second-mode wave reaches the first peak, the wall temperature rise also peaks at the same location, indicating a synchronous increase and decrease between the second-mode waves and wall temperature rise during this stage. Under different seepage flow rates, the downstream wall with microstructure-seepage experiences the lowest temperature rise when F = 0.019 19% which may be attributed to the formation of small vortices within the microstructures by the seepage.