Roman Li

Roman Li

Auto-generated profile, based on publicly available information

Roman Li


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 August 2022 in SCIENCE IN THE CENTRAL RUSSIA
Verified
Journal Article
Closed access
LULipetsk State Technical University
Lipetsk State Technical University
RLRoman Li
Roman Li
YRYulia Rizaeva
Yulia Rizaeva
ABAndrey Bykonya
Andrey Bykonya
DPDmitry Psarev
Dmitry Psarev
SUSt. Petersburg State Mining University
St. Petersburg State Mining University
One of the main disadvantages of the convective method of drying polymer coatings is their porosity. Porosity during infrared treatment is much less, and the quality of the coatings is significantly higher. However, the analysis of a priori information showed the lack of information about the infrared treatment of polymer coatings during the restoration of the body parts of the equipment. The effect of the infrared treatment regime on the mechanical properties of the F-40S elastomer-based nanocomposite was investigated. The mechanical properties of the elastomeric nanocomposite were assessed by the tensile strength of the films, relative elongation and specific deformation work when breaking the films according to the method of GOST 14236-81, the elastic modulus of the material for tension and compression - according to GOST 9550-81. The optimal mode of infrared processing of the nanocomposite was determined with an active experiment according to the V2 plan. Faulty samples were evaluated according to GOST 9407-84. As a result of regression analysis, a model of the dependence of the specific destruction work of the films of the F-40S elastomer nanocomposite on the infrared treatment mode was obtained. The optimal mode of thermal treatment of the elastomeric nanocomposite is established: 140,00S temperature, time 3.0 hours, at which the material films have the highest specific fracture work of 56.0 MJ/m3. The thermoradiation method, compared to the convective drying method, increases the strength of the nanocomposite films by 1.13 times, from 19.0 to 21.5 MPa. Infrared treatment increases the deformation of samples from 74 to 98%, 1.32 times. The stiffness of the material increased: an increase in the elastic modulus at tension from 158.3 to 161.8 MPa, by 3%, and compression - from 82.7 to 87.2 MPa, by 5.4%. The thermoradiation way, in comparison with a convective way, considerably increases quality of coverings of an elastomeric nanocomposite: the area of the destroyed covering decreases from 20 to 15%, by 1.33 times; concentration of a time in – from 0.67 to 0.54 pieces/cm2, by 1.24 times and the size of a time – from 0.109 to 0.095 mm, for 15%.

31 October 2022 in SCIENCE IN THE CENTRAL RUSSIA
Verified
Journal Article
Closed access
LULipetsk State Technical University
Lipetsk State Technical University
RLRoman Li
Roman Li
YRYulia Rizaeva
Yulia Rizaeva
ABAndrey Bykonya
Andrey Bykonya
DPDmitry Psarev
Dmitry Psarev
SUSt. Petersburg State Mining University
St. Petersburg State Mining University
Application of polymer coatings for restoration of worn-out bearing holes in housing parts of automotive equipment provides multiple increase of their service life, reduction of repair costs, improvement of reliability. The highest efficiency is achieved by applying elastomeric coatings. To cure the material and achieve high mechanical properties, the coating, after application, is subjected to thermal treatment by convective or thermoradiation methods. Coatings after treatment by a thermoradiation method, in comparison with convective, have significantly lower porosity and higher quality. A model of infrared heating of type I body parts (gearbox housing, car and tractor transfer case housing) has been developed, which takes into account the heat capacity of the material and the design parameters of the part, the ambient temperature and the steady temperature of the part during heating, the design parameters of the infrared radiation installation. The model allows you to calculate the rate of temperature increase and the time of heating the part to the required temperature by infrared heating. The article describes in detail the algorithm and provides a computer program for calculating the structural and technological parameters of the infrared processing plant for elastomeric coatings applied during the restoration of bearing holes in the body parts of the equipment. Heating of the gearbox housings of GAZ-24 and GAZ-53A cars showed a high coincidence of the design and experimental values of infrared heating parameters. The difference between the actual heating temperature of the body part and the design temperature is from 1.5 to 2.4%, the heating time is from 6.1 to 8.2%, which is a confirmation of the correctness of the developed method for calculating the structural and technological parameters of infrared installations. An experimental assessment of the quality of elastomeric coatings after heat treatment by various methods was carried out. Compared to the convective method, after infrared treatment, the quality of elastomer coatings increased F-40S: the area of the destroyed coating decreased by 1.33 times, the concentration of pores in the coating - by 1.24 times.

27 December 2023 in SCIENCE IN THE CENTRAL RUSSIA
Verified
Journal Article
Closed access
LULipetsk State Technical University
Lipetsk State Technical University
RLRoman Li
Roman Li
MKMaria Kiba
Maria Kiba
SUSt. Petersburg Mining University
St. Petersburg Mining University
DGDmitry Grebenkov
Dmitry Grebenkov
VEViktor Erokhin
Viktor Erokhin
The use of polymer composites in the restoration of worn-out body parts of agricultural machinery significantly increases their post-repair life and leads to significant savings in material resources during repair. The composite should have high mechanical and thermophysical properties, which is possible provided that the filler particles are evenly distributed in the volume of the solution. Aggregation of particles, their non-uniform distribution in the polymer solution significantly impairs the performance of the material. Mechanical mixing and dispersion of polymer composite solutions using agitators is a promising treatment method that improves the consumer properties of the material. Theoretical studies were carried out and, taking into account the physical properties of the elastomeric nanocomposite solution, the design of the open turbine stirrer was chosen. It has been found that when developing a device with a stirrer, the effect of the design parameters of the stirrer on the power consumed by the device on the mixing of components, as well as the quality of mixing and dispersion of the polymer composite solution should be taken into account. The effect of the design parameters of the stirrer on the power consumption was analyzed and the design parameters of the stirrer were determined. An active experiment according to the plan was implemented V2 in which the response function took the estimated parameter of the mixing quality of the light transmission coefficient, and the factors of the inclination angle of the stirrer blade and its rotation frequency. A regression model in the form of a second-order polynomial was obtained and its optimization was carried out. The optimal design and operating parameters of the stirrer have been established, which ensure the highest quality of mixing solutions. Based on the results of the studies, the design of an open, turbine stirrer for mixing nanocomposite solutions was developed.

31 October 2025 in SCIENCE IN THE CENTRAL RUSSIA
Verified
Journal Article
Closed access
LULipetsk State Technical University
Lipetsk State Technical University
RLRoman Li
Roman Li
MKMaria Kiba
Maria Kiba
SUSaint Petersburg Mining University
Saint Petersburg Mining University
YLYulia Li
Yulia Li
AKAlexey Komolikov
Alexey Komolikov
Known photometric methods for assessing the mixing quality of polymer composite solutions are unsuitable for monitoring polymer solutions filled with white particles. A new method for assessing the mixing quality of components in a polymer solution for filler particles of any color is proposed. This method is based on measuring the resistance of polymer composite solutions. The distribution of filler particles in the polymer solution, which correlates with the electrical resistance of the composite solution, is considered as an evaluation criterion for mixing quality. The method includes: measuring the electrical resistance of the polymer nanocomposite solution and calculating the specific volume electrical resistance; determining the average specific electrical resistance of the polymer nanocomposite solution and comparing it with the minimum rejection level on a calibration graph. It has been established that the electrical resistance of the composite solution will be maximum with a uniform distribution of dielectric particles throughout the solution. If these particles are unevenly distributed, or if aggregates occur, this will lead to current flow through the polymer solution and a decrease in electrical resistance. The electrical resistance of the composite solution will be significantly lower than with a uniform distribution. The opposite is true for a polymer solution filled with electrically conductive particles. It has been determined that the mixing quality is satisfactory if the following conditions are met: a) for dielectric particles, the average value of the measured specific volume electrical resistance should be no less than the minimum rejection level; b) for conductor particles, no greater than the minimum rejection level.

30 April 2025 in SCIENCE IN THE CENTRAL RUSSIA
Verified
Journal Article
Closed access
LULipetsk State Technical University
Lipetsk State Technical University
RLRoman Li
Roman Li
DPDmitry Psarev
Dmitry Psarev
MUMichurinsky State Agrarian University
Michurinsky State Agrarian University
MKMaria Kiba
Maria Kiba
AKAlexey Komolikov
Alexey Komolikov
Thermophysical properties of polymer fit in restored bearing units of automotive and tractor equipment are the most important characteristics determining its suitability for use under operating conditions. Metallic dispersed nanoparticles and carbon nanotubes used as fillers allow to significantly improve the thermophysical properties of elastomers and thermosets. Thermophysical properties of F-40S elastomer composites filled with ceramic nanoparticles in a volume fraction of 0.00156; 0.00311 and 0.00466 are studied in the work. The thermal conductivity coefficient increases by more than an order of magnitude: from 0.4 to 5.7 W/m‧K when filling the elastomer with ceramic nanoparticles in the optimal concentration (0.0031) The Burger formula is recommended for calculating the thermal conductivity of elastomers filled with ceramic nanoparticles, it is recommended The discrepancy between the calculated values of the thermal conductivity coefficient and the actual values does not exceed 2.5%. Filling the elastomer with ceramic nanoparticles increases the heat resistance of the material. The decrease in the strength of the nanocomposite after thermal aging is less intense than that of the elastomer: the aging coefficient for strength is 0.71, while that of the elastomer is 0.63. The effect of thermal aging on the change in deformation is similar: the aging coefficient for deformation of the composite is 0.37, and that of the elastomer is 0.31. Filling the elastomer with ceramic nanoparticles in the optimal concentration increases the thermal conductivity coefficient by 14.25 times. Aluminum oxide nanoparticles are inhibitors of thermal oxidation of butadiene-nitrile rubber SKN-40 and increase the thermal resistance of the F-40S elastomer: the aging coefficients for strength increase by 1.13 times, for deformation by 1.19 times.

30 August 2024 in SCIENCE IN THE CENTRAL RUSSIA
Verified
Journal Article
Closed access
LULipetsk State Technical University
Lipetsk State Technical University
RLRoman Li
Roman Li
MKMaria Kiba
Maria Kiba
SUSaint Petersburg Mining University
Saint Petersburg Mining University
VEVictor Erokhin
Victor Erokhin
MUMichurinsk State Agrarian University
Michurinsk State Agrarian University
LSTU has developed a turbine stirrer for mixing and dispersing solutions of polymer nanocomposites designed to restore mounting holes in the body parts of equipment. Formula is proposed for calculation of optimal rotation frequency of turbine mixer, which takes into account structural parameters of mixer and physical properties of nanoparticles, which provides effective mixing of nanoparticles of filler in solution of nanocomposite. An experiment was carried out to assess the adequacy of a mathematical model of the turbine stirrer speed. Experimental turbine agitators of three different sizes were used in the experiment. A solution of elastomer nanocomposite F-40S was used for mixing. The dispersion quality was evaluated by the light transmission coefficient. For each turbine stirrer size, experimental non-linear dependences of the transmittance on the stirrer speed were obtained. After approximation of experimental dependences and taking partial derivatives, their extremes are determined, i.e. actual optimal rotation frequencies for each mixer size: n оф1 = 1325 min-1; nof2 = 1113 min-1;, nof3 = 973 min-1. Then the power consumed by stirrers of various sizes at a speed of 500, 1000 and 1500 min-1 was measured. Further, the values of the circumferential velocity coefficients k were calculated for each stirrer using the measured power values. As the stirrer diameter increases from 34 to 90 mm, the corresponding circumferential velocity factor k increases from 0.9534 to 0.9703, indicating an increase in circumferential flow.Further, according to the proposed formula, using the values of the coefficients of peripheral speeds, the calculated values of the optimal speed for stirrers No. 1, No. 2 and No. 3 were obtained: n op1 = 1307 min-1; nop2 = 1100 min-1;, nop3 = 965 min-1. Analysis of variance showed that the calculated Fischer value does not exceed the table value, which confirms the adequacy of the formula for calculating the optimal speed of the turbine stirrer.