Weiyang Yan

Weiyang Yan

Auto-generated profile, based on publicly available information

Weiyang Yan

New energy and power grid equipment safety monitoring Hubei Engineering Research, Hubei University of Technology, Wuhan, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
GZGuozhi Zhang
Guozhi Zhang
LWLingyi Wang
Lingyi Wang
WYWeiyang Yan
Weiyang Yan
GDGuangyu Deng
Guangyu Deng
CLChangyue Lu
Changyue Lu
XZXiaoxing Zhang
Xiaoxing Zhang
Compared to stationary insulation oil, the agglomeration characteristics of fiber particles and their accompanying partial discharge characteristics in flowing insulation oil are more complex. In order to investigate the effects of voltage amplitude, agglomeration level, and oil flow velocity on the agglomeration characteristics of fiber particles and their accompanying partial discharge characteristics, an experimental platform for high-voltage direct current discharge detection under oil flow conditions was established in this study. The research findings are as follows: when the oil flow velocity and voltage amplitude are constant, with the increase of continuous pressurization time, the partial discharge quantity accompanying the agglomeration of fiber particles between the electrodes will rapidly increase when the fiber particles aggregate to form a through "impurity small bridge". The impact of voltage amplitude on the agglomeration of fiber particles and the characteristics of their associated discharges is more significant than that of oil flow velocity and agglomeration level. In a high-voltage direct current (HVDC) uniform electric field. It’s observed that the UHF signals detected are characterized as half-wave signals. As the velocity of the oil flow increases, there’s a noticeable reduction in the discharge quantity of agglomerated fiber particles, and the effectiveness of flow velocity in mitigating partial discharges starts to wane. At an oil flow velocity of 0.2 m/s and a voltage level of 16 kV, fiber particles show minimal agglomeration between electrodes. At the same duration of continuous pressurization, the degree of aggregation of fiber impurity particles between the electrodes gradually increases with the rise in voltage amplitude.

1 August 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
GZGuozhi Zhang
Guozhi Zhang
LWLingyi Wang
Lingyi Wang
WYWeiyang Yan
Weiyang Yan
XZXiaoxing Zhang
Xiaoxing Zhang