A new remote catheter system (AMIGO™ Remote Catheter System) compatible with conventional ablation catheters is now commercially available but no data about its performance in clinical use during ablation have been reported. This study evaluates the feasibility, efficacy, and safety of cavo-tricuspid isthmus (CTI) ablation with this system in patients with typical atrial flutter (AFl). Sixty patients with typical AFl underwent CTI ablation using the new remote catheter navigation system with 8 mm tip or irrigated catheters in three centres following each centre's routine practice. The endpoint was stable bidirectional CTI block. CTI ablation was successful in 98% of patients. Ablation was completed manually in one patient. The overall procedure, fluoroscopy, and radiofrequency times (median ± standard deviation, range) were 123 ± 42 (50–250), 24 ± 13 (3–82), and 10 ± 8 (1.17–43.3) min, respectively. Three patients had vascular complications not requiring surgical intervention. There were no complications related to the remote catheter manipulation system. Cavo-tricuspid isthmus ablation for typical AFl can be safely and effectively performed with the AMIGO™. The learning curve seems to be short even for physicians with limited ablation experience.
Objective A safety threshold for baseline rhythm R-wave amplitudes during follow-up of implantable cardioverter defibrillators (ICD) has not been established. We aimed to analyse the amplitude distribution and undersensing rate during spontaneous episodes of ventricular fibrillation (VF), and define a safety amplitude threshold for baseline R-waves. Methods Data were obtained from an observational multicentre registry conducted at 48 centres in Spain. Baseline R-wave amplitudes and VF events were prospectively registered by remote monitoring. Signal processing algorithms were used to compare amplitudes of baseline R-waves with VF R-waves. All undersensed R-waves after the blanking period (120 ms) were manually marked. Results We studied 2507 patients from August 2011 to September 2014, which yielded 229 VF episodes (cycle length 189.6±29.1 ms) from 83 patients that were suitable for R-wave comparisons (follow-up 2.7±2.6 years). The majority (77.6%) of VF R-waves (n=13953) showed lower amplitudes than the reference baseline R-wave. The decrease in VF amplitude was progressively attenuated among subgroups of baseline R-wave amplitude (≥17; ≥12 to <17; ≥7 to <12; ≥2.2 to <7 mV) from the highest to the lowest: median deviations −51.2% to +22.4%, respectively (p=0.027). There were no significant differences in undersensing rates of VF R-waves among subgroups. Both the normalised histogram distribution and the undersensing risk function obtained from the ≥2.2 to <7 mV subgroup enabled the prediction that baseline R-wave amplitudes ≤2.5 mV (interquartile range: 2.3–2.8 mV) may lead to ≥25% of undersensed VF R-waves. Conclusions Baseline R-wave amplitudes ≤2.5 mV during follow-up of patients with ICDs may lead to high risk of delayed detection of VF. Trial registration number NCT01561144; results.