11 August 2014 in Neurogastroenterology & Motility
3 January 2015 in Neurogastroenterology & Motility
27 March 2013 in British Journal of Surgery
Background Sacral nerve stimulation (SNS) is an effective treatment for neurogenic faecal incontinence (FI). However, the clinical improvement that patients experience cannot be explained adequately by changes in anorectal function. The aim of this study was to examine the effect of SNS on colonic propagating sequences (PSs) in patients with FI in whom urgency and incontinence was the predominant symptom. Methods In patients with FI a high‐resolution fibre‐optic manometry catheter, containing 90 sensors spaced at 1‐cm intervals, was positioned colonoscopically and clipped to the caecum. A unipolar or quadripolar tined electrode was implanted into the S3 sacral nerve foramen. Colonic manometry was evaluated in a double‐blind randomized crossover trial, using true suprasensory stimulation or sham stimulation. Each stimulation period, lasting 2 h, was preceded by a 2‐h basal manometric recording. Results All 11 patients studied showed a colonic response to SNS. In ten patients there was a significant increase in the frequency of retrograde PSs throughout the colon during true stimulation compared with sham stimulation (P = 0·014). In one outlier, with baseline retrograde PS frequency nine times that of the nearest patient, a reduction in retrograde PS frequency was recorded. Compared with sham stimulation, SNS had no effect on the frequency of antegrade PSs or high‐amplitude PSs. Conclusion SNS modulates colonic motility in patients with faecal urge incontinence. These data suggest that SNS may improve continence and urgency through alteration of colonic motility, particularly by increasing retrograde PSs in the left colon.
23 November 2009 in Optics Express
The design of a fibre Bragg grating based manometry catheter for in-vivo diagnostics in the human colon is presented. The design is based on a device initially developed for use in the oesophagus, but in this instance, longer sensing lengths and increased flexibility were required to facilitate colonoscopic placement of the device and to allow access to the convoluted regions of this complex organ. The catheter design adopted allows the number of sensing regions to be increased to cover extended lengths of the colon whilst maintaining high flexibility and the close axial spacing necessary to accurately record pertinent features of peristalsis. Catheters with 72 sensing regions with an axial spacing of 1 cm have been assembled and used in-vivo to record peristaltic contractions in the human colon over a 24hr period. The close axial spacing of the pressure sensors has, for the first time, identified the complex nature of propagating sequences in both antegrade (towards the anus) and retrograde (away from the anus) directions in the colon. The potential to miss propagating sequences at wider sensor spacings is discussed and the resultant need for close axial spacing of sensors is proposed.
17 June 2013 in Neurogastroenterology & Motility
1 May 2017 in American Journal of Physiology-Gastrointestinal and Liver Physiology
Colonic cyclic motor patterns (CMPs) have been hypothesized to act as a brake to limit rectal filling. However, the spatiotemporal profile of CMPs, including anatomic origins and distributions, remains unclear. This study characterized colonic CMPs using high-resolution (HR) manometry (72 sensors, 1-cm resolution) and their relationship with proximal antegrade propagating events. Nine healthy volunteers were recruited. Recordings were performed over 4 h, with a 700-kcal meal given after 2 h. Propagating events were visually identified and analyzed by pattern, origin, amplitude, extent of propagation, velocity, and duration. Manometric data were normalized using anatomic landmarks identified on abdominal radiographs. These were mapped over a three-dimensional anatomic model. CMPs comprised a majority of detected propagating events. Most occurred postprandially and were retrograde propagating events (84.9 ± 26.0 retrograde vs. 14.3 ± 11.8 antegrade events/2 h, P = 0.004). The dominant sites of initiation for retrograde CMPs were in the rectosigmoid region, with patterns proximally propagating by a mean distance of 12.4 ± 0.3 cm. There were significant differences in the characteristics of CMPs depending on the direction of travel and site of initiation. Association analysis showed that proximal antegrade propagating events occurred independently of CMPs. This study accurately characterized CMPs with anatomic correlation. CMPs were unlikely to be triggered by proximal antegrade propagating events in our study context. However, the distal origin and prominence of retrograde CMPs could still act as a mechanism to limit rectal filling and support the theory of a “rectosigmoid brake.” NEW & NOTEWORTHY Retrograde cyclic motor patterns (CMPs) are the dominant motor patterns in a healthy prepared human colon. The major sites of initiation are in the rectosigmoid region, with retrograde propagation, supporting the idea of a “rectosigmoid brake.” A significant increase in the number of CMPs is seen after a meal. In our study context, the majority of CMPs occurred independent of proximal propagating events, suggesting that CMPs are primarily controlled by external innervation.