29 September 2010 in Food and Environmental Virology
RMRosa A. Martínez-Bustillos
Rosa A. Martínez-Bustillos
1 April 2012 in Journal of International Medical Research
OBJECTIVE: A randomized clinical study to compare the stress response to laparoscopic cholecystectomy during spinal—general anaesthesia and epidural—general anaesthesia. METHODS: Women undergoing elective laparoscopic cholecystectomy were assigned to receive either spinal anaesthesia (SA group; n = 12) or epidural anaesthesia (EA group; n = 12), in addition to general anaesthesia. Plasma concentrations of cortisol, adrenocortico trophic hormone (ACTH), noradrenaline, adrenaline and total catecholamines were measured pre- and intraoperatively. RESULTS: Intraoperative cortisol, noradrenaline and total catecholamine levels were significantly lower in the SA group compared with the EA group. When pre- and intraoperative values were compared, the SA group showed a decrease in adrenaline, noradrenaline and total catecholamine levels, and the EA group showed an increase in ACTH and noradrenaline levels. CONCLUSIONS: The type of regional anaesthesia significantly affected the stress response: spinal anaesthesia produced a more favourable endocrine response than epidural anaesthesia. Spinal—general anaesthesia may reduce postoperative morbidity in laparoscopic cholecystectomy.
1 October 2017 in Revista Mexicana de Ortodoncia
ASAline Bojórquez Steffani
To characterize radiographically the periodontal ligament thickness (PLT) and pain perception (PP) at the beginning of orthodontic treatment by activating and applying infrared laser of 810 nm each month for three months. It was a quasi-experimental, descriptive and longitudinal study with a non-probabilistic sample consisting of 10 patients from the clinic of Orthodontics and Orthopedics at the Autonomous University of Sinaloa. 200 measurements were performed in teeth #11 and 12 (laser-treated); and 21 and 22 (non-treated control). To measure the PLT periapical radiographs were analyzed with Motic software 3V Advance. For PP determination, visual analog scale (VAS) was used. Descriptive statistical analysis was performed with SPSS v-19 (confidence interval of 95%). In laser-treated teeth, PLT increased significantly 0.719 μm from the first to the second measurement and decreased 0.648 μm in the third measurement. In non-treated control teeth, PLT increased averaging 1.011 μm without significant change in the third measurement. PP in control teeth averaged 3.7 ± 3.2 on the VAS scale in the first measurement and 2.3 ± 2.3 in the second; while in the irradiated zone they averaged 2.9 ± 2.8 in the first month and 1.4 ± 1.2 in the second. With laser treatment, PLT is significantly reduced in comparison to the group that did not receive the treatment. At one and two months of treatment, average of PP decreased both in teeth where the laser is applied as in those without. Caracterizar radiográficamente el grosor del ligamento periodontal (gLPD) y la percepción dolorosa (PD) al inicio de tratamiento ortodóntico activando y aplicando láser infrarrojo de 810 nm cada mes durante tres meses. Estudio cuasiexperimental, descriptivo, longitudinal, muestra no probabilística de 10 pacientes de la Clínica de Ortodoncia y Ortopedia de la Universidad Autónoma de Sinaloa. Se realizaron 200 mediciones en las piezas 11 y 12 (con tratamiento láser); y 21 y 22 (sin tratamiento). Para medir el gLPD se analizaron radiografías periapicales con el software Motic Advance 3V. Para la PD se usó la escala visual analógica (EVA). El análisis estadístico descriptivo se realizó con SPSS v-19 (intervalo de confianza de 95%). En las piezas tratadas con láser, el gLPD aumentó significativamente 0.719 μm de la primera a la segunda medición, y disminuyó 0.648 μm en la tercera medición. En las piezas control, el gLPD aumentó promediando 1.011 μm sin cambio significativo en la tercera medición. La PD en las piezas control en la escala EVA promediaron 3.7 ± 3.2 en la primera medición, y 2.3 ± 2.3 en la segunda; mientras que en la zona irradiada promediaron 2.9 ± 2.8 en el primer mes y 1.4 ± 1.2 en el segundo. El gLPD disminuye significativamente al aplicar el láser con respecto al grupo que no se le aplicó tratamiento. El promedio de la PD al mes y a los dos meses de tratamiento, disminuyó tanto en las piezas donde se aplicó el láser como en las que no.
1 November 2017 in Journal of Minimally Invasive Gynecology
15 January 2022 in REVMEDUAS
KGKaren Analí García-Medina
Karen Analí García-Medina
RCRicardo Daniel Chávez-Gutiérrez
Ricardo Daniel Chávez-Gutiérrez