Lijian Ge

Lijian Ge

Auto-generated profile, based on publicly available information

Lijian Ge

State Key Laboratory of Nuclear Physics and Technology, Peking University 1 , Beijing 100871, China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 August 2016 in Review of Scientific Instruments
Verified
Journal Article
Closed access
GZG. Q. Zhong
G. Q. Zhong
LHL. Q. Hu
L. Q. Hu
NPN. Pu
N. Pu
RZR. J. Zhou
R. J. Zhou
MXM. Xiao
M. Xiao
ETEast Team
East Team
Neutron diagnostics have become a significant means to study energetic particles in high power auxiliary heating plasmas on the Experimental Advanced Superconducting Tokamak (EAST). Several kinds of neutron diagnostic systems have been implemented for time-resolved measurements of D-D neutron flux, fluctuation, emission profile, and spectrum. All detectors have been calibrated in laboratory, and in situ calibration using 252Cf neutron source in EAST is in preparation. A new technology of digitized pulse signal processing is adopted in a wide dynamic range neutron flux monitor, compact recoil proton spectrometer, and time of flight spectrometer. Improvements will be made continuously to the system to achieve better adaptation to the EAST’s harsh γ-ray and electro-magnetic radiation environment.

16 July 2018 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Closed access
PDF file
LGLijian Ge
Lijian Ge
ZHZhimeng Hu
Zhimeng Hu
YZYimo Zhang
Yimo Zhang
JSJiaqi Sun
Jiaqi Sun
XYXi Yuan
Xi Yuan
TFTieshuan Fan
Tieshuan Fan
Neutron emission spectroscopy (NES) measurement aimed at providing the information on fast ions induced by auxiliary heating systems at Experimental Advanced Superconducting Tokamak (EAST), with a liquid scintillation detector is described. It is the first time that the NES diagnostics are employed to probe fast ions induced by neutral beam injection (NBI) at EAST. The time trace of the fusion neutrons, obtained by the liquid scintillation detector, was consistent with the result measured by a standard 235 U fission chamber under NBI heating scenario, which verifies the performance of the detector. NUBEAM code is used to determine the fast deuteron velocity distribution using the parametrized plasma profiles as input. The pulse height spectrum of the fusion neutrons was successfully reproduced by combining the simulation of the neutron energy spectrum and the calculation of the detector response functions. The experimental data are also interpreted from a view of weight functions, which illustrate the velocity-space sensitivity of the liquid scintillation detector with a radial line of sight. The results demonstrate the capability of the liquid scintillation detector to contribute to studies on fast-ion physics at EAST.

1 May 2021 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
YZYimo Zhang
Yimo Zhang
LGLijian Ge
Lijian Ge
ZHZhimeng Hu
Zhimeng Hu
JSJiaqi Sun
Jiaqi Sun
XLXiangqing Li
Xiangqing Li
TFTieshuan Fan
Tieshuan Fan
A time-of-flight neutron spectrometer based on the Time-Of-Flight Enhanced Diagnostic (TOFED) concept has been designed and is under development for the Large Helical Device (LHD). It will be the first advanced neutron spectrometer to measure the 2.45 MeV D–D neutrons (DDNs) from helical/stellarator plasmas. The main mission of the new TOFED is to study the supra-thermal deuterons generated from the auxiliary heating systems in helical plasmas by measuring the time-of-flight spectra of DDN. It will also measure the triton burnup neutrons (TBNs) from the d+t reactions, unlike the original TOFED in the EAST tokamak. Its capability of diagnosing the TBN ratios is evaluated in this work. This new TOFED is expected to be installed in the basement under the LHD hall and shares the collimator with one channel of the vertical neutron camera to define its line of sight. The distance from its primary scintillators to the equatorial plane of LHD plasmas is about 15.5 m. Based on Monte Carlo simulation by a GEANT4 model, the resolution of the DDN energy spectra is 6.6%. When projected onto the neutron rates that are typically obtained in LHD deuterium plasmas (an order of 1015 n/s with neutral beam injection), we expect to obtain the DDN and TBN counting rates of about 2.5 · 105 counts/s and 250 counts/s, respectively. This will allow us to analyze the DDN time-of-flight spectra on time scales of 0.1 s and diagnose the TBN emission rates in several seconds with one instrument, for the first time in helical/stellarator plasmas.

1 April 2021 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
LLLongyong Liao
Longyong Liao
YZY. M. Zhang
Y. M. Zhang
ZHZ. M. Hu
Z. M. Hu
DYD. K. Yang
D. K. Yang
LGL. J. Ge
L. J. Ge
TFTieshuan Fan
Tieshuan Fan
Stilbene crystal detectors are widely used as fast neutron measurement tools based on recoil proton detection, such as liquid scintillators. A compact stilbene crystal neutron spectrometer (CSCNS) has been installed at the Experimental Advanced Superconducting Tokamak (EAST) to obtain information on fuel ions produced in the plasma core because of its merits of good n/γ discrimination capability, high detection efficiency, and fast response. For the first time, CSCNS has been used for neutron emission spectroscopy measurements in EAST plasmas with neutral beam injection (NBI) heating. The CSCNS has the same horizontal line of sight as the time-of-flight enhanced diagnostics neutron spectrometer. Under NBI heating scenarios, the time trace of the neutron yield monitored by the CSCNS is similar to the one monitored by a standard 235U fission chamber. The experimental pulse height spectra are also similar to the simulated ones generated by folding the simulated neutron energy spectrum with the detector response functions. These results demonstrate the capability of the CSCNS for neutron diagnostics and the study of fast-ion physics in EAST.