Christian Goetz

Christian Goetz

Auto-generated profile, based on publicly available information

Christian Goetz

Heidelberg University Hospital

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2025 in EP Europace
Verified
Journal Article
Open access
TATill F. Althoff
Till F. Althoff
RARobert Henry Anderson
Robert Henry Anderson
CGChristian Goetz
Christian Goetz
SPSteffen Petersen
Steffen Petersen
PDPatricia Martínez Díaz
Patricia Martínez Díaz
SHSiew Yen Ho
Siew Yen Ho
This clinical consensus document proposes standardized atrial segments for 3D imaging, electroanatomical mapping and computational modelling, based on anatomical, electrophysiological and clinical considerations, with precise definitions of regional borders allowing for reproducible and automated regionalization. 3D imaging and high-resolution electroanatomical mapping have become an integral part of cardiac electrophysiology and the management of patients with arrhythmias. However, to perform regional quantitative analyses and intra- and inter-individual, as well as cross-modality comparisons, a universal definition of atrial regions and their boundaries is required. While for the left ventricle there is already an established standardized regionalization (AHA 17-segment model), there is no such consensus for the atria. In a multi-disciplinary writing group consisting of cardiologists, cardiac electrophysiologists, cardiovascular imaging specialists, and anatomists as well as specialists in computational cardiac modelling from European Heart Rhythm Association and European Association of Cardiovascular Imaging, a standardized regionalization based on a 15-segment bi-atrial model was elaborated. This clinical consensus document will enable consistent regional analyses and homogeneous data acquisition across different centres and modalities, and may thus have a significant impact on atrial arrhythmia research and personalized treatment approaches based on individual arrhythmia patterns and phenotypes.

23 August 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
PDPatricia Martínez Díaz
Patricia Martínez Díaz
ADAlbert Dasí
Albert Dasí
CGChristian Goetz
Christian Goetz
LULaura A Unger
Laura A Unger
AHAnnika Haas
Annika Haas
ALAxel Loewe
Axel Loewe
The effective refractory period (ERP) is one of the main electrophysiological properties governing arrhythmia, yet ERP personalization is rarely performed when creating patient-specific computer models of the atria to inform clinical decision-making. This study evaluates the impact of integrating clinical ERP measurements into personalized in silico models on arrhythmia vulnerability. Clinical ERP measurements were obtained in seven patients from multiple locations in the atria. Atrial geometries from the electroanatomical mapping system were used to generate personalized anatomical atrial models. The Courtemanche M. et al. cellular model was adjusted to reproduce patient-specific ERP. Four modeling approaches were compared: homogeneous (A), heterogeneous (B), regional (C), and continuous (D) ERP distributions. Non-personalized approaches (A and B) were based on literature data, while personalized approaches (C and D) were based on patient measurements. Modeling effects were assessed on arrhythmia vulnerability and tachycardia cycle length, with sensitivity analysis on ERP measurement uncertainty. Mean vulnerability was 3.4 ± 4.0%, 7.7 ± 3.4%, 9.0 ± 5.1%, and 7.0 ± 3.6% for scenarios A–D, respectively. Mean tachycardia cycle length was 167.1 ± 12.6 ms, 158.4 ± 27.5 ms, 265.2 ± 39.9 ms, and 285.9 ± 77.3 ms for scenarios A–D, respectively. Incorporating perturbations to the measured ERP in the range of 2, 5, 10, 20, and 50 ms changed the vulnerability of the model to 5.8 ± 2.7%, 6.1 ± 3.5%, 6.9 ± 3.7%, 5.2 ± 3.5%, and 9.7 ± 10.0%, respectively. Increased ERP dispersion had a greater effect on re-entry dynamics than on vulnerability. Inducibility was higher in personalized scenarios compared with scenarios with uniformly reduced ERP; however, this effect was reversed when incorporating fibrosis informed by low-voltage areas. Effective refractory period measurement uncertainty up to 20 ms slightly influenced vulnerability. Electrophysiological personalization of atrial in silico models appears essential and requires confirmation in larger cohorts.

23 April 2026 in medRxiv
Verified
Preprint
Open access
PDF file
CGChristian Goetz
Christian Goetz
MEMartin Eichenlaub
Martin Eichenlaub
KSKerstin Schmidt
Kerstin Schmidt
FWFelix Wiedmann
Felix Wiedmann
EREric Invers Rubio
Eric Invers Rubio
ALAxel Loewe
Axel Loewe
The recently published EHRA/EACVI consensus statement on a standardized bi-atrial regionalization provides new opportunities for consistent regional analyses across patients, imaging modalities and clinical centers. To make this standardized regionalization widely accessible, we developed the open-source software DIVAID, which automatically divides bi-atrial geometries according to the proposed regions, ensuring consistency, reproducibility and operator independence. We evaluated the accuracy of the algorithm by comparing its results to manual expert annotations across 140 geometries from multiple modalities and centers. Veins were automatically clipped correctly in 81% and orifices annotated correctly in 100 % of cases. The median (interquartile range; IQR) Dice similarity coefficient (DSC) for left atrial regions was 0.98 (0.96 – 1.00) for DIVAID-expert and 0.98 (0.94 – 1.00) for inter-expert comparisons. For right atrial geometries, DSC was higher for DIVAID-expert than for inter-expert comparisons at 0.90 (0.80 – 0.95) and 0.88 (0.74 – 0.94), respectively. To assess the accuracy of regional boundaries, we computed the mean average surface distance (MASD) for boundaries derived from automatic or manual annotations. The median (IQR) MASD between DIVAID and experts was 0.17 mm (0.03 – 0.78) and 1.93 mm (0.65 – 3.96) in the left and right atrium, respectively. To conclude, DIVAID robustly divides anatomically diverse bi-atrial geometries according to the 15-segment model, while outperforming cardiac experts in both speed and consistency, and demonstrating an accuracy of regional boundaries comparable to the spatial resolution of cardiac imaging modalities. By providing automated, consistent atrial regionalization, DIVAID enables large-scale, standardized regional analyses and data-driven investigation of harmonized, multi-dimensional datasets, which may advance atrial arrhythmia research and personalized treatment strategies.

24 May 2024 in EP Europace
Verified
Journal Article
Open access
TATill F. Althoff
Till F. Althoff
CGC Goetz
C Goetz
LML P Martinez
L P Martinez
EIE Invers-Rubio
E Invers-Rubio
SHS Hussain
S Hussain
MGM S Guillem
M S Guillem
Background: 3D imaging and high-resolution electroanatomical mapping have become an integral part of cardiac electrophysiology and the management of patients with arrhythmias. With further technological advances the significance of these modalities continues to grow. However, to perform regional quantitative analyses and intra- and inter-individual, as well as cross-modality comparisons, a universal definition of atrial regions and their boundaries is required. While for the left ventricle there is already an established standardized regionalization (AHA 18-segment model), there is no consensus for the regionalization of the atria. Purpose: Here we propose standardized left and right atrial segments based on anatomical, electrophysiological and clinical considerations, with precise definition of regional boundaries allowing for reproducible and automated regionalization. Methods and results: In a multidisciplinary task force of the European PersonalizeAF consortium involving cardiologists and cardiac electrophysiologists, as well as specialists in cardiac imaging and computational modeling we developed a standardized regionalization dividing the left atrium into eight, and the right atrium into seven segments (15-segment bi-atrial model) (Fig. 1A). As a proof-of-principle, two software algorithms for automatic regionalization of 3D atrial geometries based on the standardized 15-segment bi-atrial model were developed independently by different working groups of the PersonalizeAF consortium – one based on a commercially available software, the other being open-source. The algorithm based on the commercial software obtains the 15-segment bi-atrial model by dividing the surface mesh in the defined regions along geodesics using the Fast Marching Method (Fig. 1C). For the open-source solution, a publicly available semi-automatic bi-atrial division pipeline was developed: In this algorithm, after standardizing the surface mesh by remeshing and clipping the pulmonary veins, the orifices are annotated automatically. Based on these anatomical landmarks, the boundaries of each region are inferred by calculating geodesics using Dijkstra’s algorithm. Both algorithms were able to annotate the regions with high accuracy and very good agreement as indicated by interrater reliability testing (kappa >0.9), in geometries derived from 50 patients and 2 imaging modalities (CT and MRI), thus demonstrating the universal applicability and reproducibility of the standardized segments. Conclusion: We propose a standardized regionalization of the cardiac atria for 3D cardiac imaging, electroanatomical mapping and computational modeling, based on anatomical, electrophysiological and clinical considerations. The reproducibility and universal applicability of this 15-segment bi-atrial model was demonstrated by two independently developed software algorithms for automatic regionalization.

7 June 2024 in medRxiv
Verified
Preprint
Open access
PDF file
PDPatricia Martínez Díaz
Patricia Martínez Díaz
ADAlbert Dasí
Albert Dasí
CGChristian Goetz
Christian Goetz
LULaura Unger
Laura Unger
AHAnnika Haas
Annika Haas
ALAxel Loewe
Axel Loewe
Background and Aims: The effective refractory period is one of the main electrophysiological properties governing arrhythmia maintenance, yet effective refractory period personalisation is rarely performed when creating patient-specific computer models of the atria to inform clinical decision-making. The aim of this study is to evaluate the impact of incorporating clinical effective refractory period measurements when creating in silico personalised models on arrhythmia vulnerability. Methods: Clinical effective refractory period measurements were obtained in seven patients from multiple locations in the atria. The atrial geometries from the electroanatomical mapping system were used to generate personalised anatomical atrial models. To reproduce patient-specific refractory period measurements, the Courtemanche cellular model was gradually reparameterised from control conditions to a setup representing atrial fibrillation-induced remodelling. Four different modelling approaches were compared: homogeneous (A), heterogeneous (B), regional (C), and continuous (D) distribution of effective refractory period. The first two configurations were non-personalised based on literature data, the latter two were personalised based on patient measurements. We evaluated the effect of each modelling approach by quantifying arrhythmia vulnerability and tachycardia cycle length. We performed a sensitivity analysis to assess the influence of effective refractory period measurement uncertainty on arrhythmia vulnerability. Results: The mean vulnerability was 3.4±4.0%, 7.7±3.4%, 9.0±5.1%, 7.0±3.6% for scenarios A to D, respectively. The mean tachycardia cycle length was 167.1±12.6ms, 158.4±27.5ms, 265.2±39.9ms, and 285.9±77.3ms for scenarios A to D, respectively. Incorporating perturbations to the measured effective refractory period in the range of 2, 5, 10 and 20ms, had an impact on the vulnerability of the model of 5.8±2.7%, 6.1±3.5%, 6.9±3.7%, 5.2±3.5%, respectively. Conclusion: Increased dispersion of the effective refractory period had a greater effect on reentry dynamics than on mean vulnerability values. The incorporation of personalised effective refractory period in the form of gradients had a greater impact on vulnerability than had a homogeneously reduced effective refractory period. Effective refractory period measurement uncertainty up to 20ms slightly influences arrhythmia vulnerability. Electrophysiological personalisation of atrial in silico models appears essential and warrants confirmation in larger cohorts.

15 September 2026 in Journal of the American Heart Association
Verified
Journal Article
Open access
APAmelie Paasche
Amelie Paasche
FWFelix Wiedmann
Felix Wiedmann
CGChristian Goetz
Christian Goetz
LWLeo Weirauch
Leo Weirauch
LVLize‐Maria Verhaeghe
Lize‐Maria Verhaeghe
CSConstanze Schmidt
Constanze Schmidt
Background: Atrial arrhythmias relevantly contribute to global morbidity and death and have been extensively studied in experimental models. However, electrophysiological disparities between animal models and humans often hinder the translation of experimental findings. This study aims to systematically characterize species‐specific atrial electrophysiology to improve translation. Methods: Atrial tissue samples were obtained from patients undergoing open heart surgery and from mice, rats, pigs, and horses, and were characterized at the cellular electrophysiological and transcriptomic level using uniform protocols. To assess the correlation of functional and transcriptomic features, action potentials were simulated from ion channel expression profiles using in silico models. Results: Porcine atrial cardiomyocytes closely resembled human cells in depolarization characteristics, whereas rodents exhibited marked differences. Human atrial action potentials showed pronounced early repolarization, which was not reproduced in other species and corresponded to a greater contribution of the I Kur gene group. Late repolarization, reflected by action potential duration at 90% repolarization, scaled with species and cardiomyocyte size, with humans ranging between rodents and pigs. Sex‐specific differences in repolarization observed in humans were represented in pigs but not in rodents. Chamber‐specific differences between left and right atrial cardiomyocytes were reflected in in silico simulations on the basis of ion channel expression. Conclusions: This study provides a reference for species‐specific atrial action potential characteristics, linking functional properties to transcriptomic ion channel expression. It further demonstrates that relative changes in action potential parameters can be inferred from transcriptomic data using in silico simulations. These findings support more accurate interpretation and translation of animal experimental data to human atrial electrophysiology.